{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2110-1HA15-1AP6","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2110-1HA15-1AP6","canonicalUrl":"https://aoctrl.com/siemens/3RA2110-1HA15-1AP6","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2110-1HA15-1AP6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2110-1HA15-1AP6 non-fused motor starter, size S00, direct starter, thermal bimetallic overload, Class 10, 3 hp at 480 V, 690 V max AC-3, snap-on DIN rail.","salesMarkdown":"## SIRIUS 3RA2 non-fused motor starter, size S00 The Siemens 3RA2110-1HA15-1AP6 is a SIRIUS non-fused motor starter in size S00, combining a contactor and a thermal bimetallic overload relay in one unit for direct starting of three-phase motors. It ships with the 3RT2015-1AP61 contactor and the 3RA1921-1DA00 link module, so the assembly is matched from the factory — no separate component selection needed. ## Motor power and current ratings across common voltages At 480 V the starter is rated 3 hp and 4.8 A; at 600 V it delivers 5 hp and 6.1 A, covering the most common North American motor frames up to that size. For 50 Hz markets, the coil accepts 187…242 V at 50 Hz and 192…264 V at 60 Hz, so it works across the standard European and North American control voltages without a coil swap. Maximum AC-3 switching voltage is 690 V, matching the insulation rating of the S00 frame. ## Class 10 trip and mounting flexibility Mounting is snap-on to 35 mm DIN rail or screw-mount with an additional push-in lug, and the unit is rated for vertical installation only — plan the panel layout accordingly. Clearance requirements: 20 mm upwards, 10 mm downwards, and 9 mm at the sides — no extra space needed forwards or backwards, which helps in tight enclosures.","metaTitle":"Siemens 3RA2110-1HA15-1AP6 SIRIUS Motor Starter","metaDescription":"Siemens 3RA2110-1HA15-1AP6 SIRIUS non-fused motor starter, size S00, 3 hp at 480 V, Class 10 thermal overload. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Starters"],"specifications":{"Depth":"97.1 mm","Width":"45 mm","title":"3RA2110-1HA15-1AP6","Height":"167.2 mm","Upwards":"20 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"690 V","description":"Fuseless motor starter Direct start 600VAC Size S00 5.5-8Amp 220/240VAC 50/60HZ screw connection For screw mounting Or 35 mm rail-mounting Type of coordination 1 1NO (contactor)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-55 ... +80 °C","Fastening Method":"Snap-mounted to DIN rail or screw-mounted with additional push-in lug","Mounting Position":"vertical","Product Brand Name":"SIRIUS","Type Of Assignment":"1","Degree Of Pollution":"3","Product Designation":"non-fused motor starter 3RA2","Size Of Load Feeder":"S00","at 230 V rated value":"0.5 hp","at 400 V rated value":"3 000 W","at 480 V rated value":"4.8 A","at 50 Hz rated value":"187 ... 242 V","at 500 V rated value":"4 000 W","at 60 Hz rated value":"192 ... 264 V","at 600 V rated value":"6.1 A","Design Of The Product":"direct starter","at 110/120 V rated value":"0.25 hp","at 200/208 V rated value":"1.5 hp","at 220/230 V rated value":"2 hp","at 460/480 V rated value":"3 hp","at 575/600 V rated value":"5 hp","Of The Supplied Contactor":"3RT2015-1AP61","Of The Supplied Link Module":"3RA1921-1DA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","Design Of The Overload Release":"thermal (bimetallic)","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-1HA10","Product Extension Auxiliary Switch":"Yes","Surge Voltage Resistance Rated Value":"6 kV","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","apparent holding power of magnet coil at AC":"4.8 VA","number of NO contacts for auxiliary contacts":"1","shock resistance according to IEC 60068-2-27":"6g / 11 ms","at 400 V according to IEC 60947-4-1 rated value":"153 000 A","operational current at AC-3 at 400 V rated value":"6.5 A","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","Inductive Power Factor With The Holding Power Of The Coil":"0.25","Mechanical Service Life (Operating Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"104 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Type Of Connectable Conductor Cross-Sections For Main Contacts Stranded":"0.5 ... 4 mm², 2x (0.75 ... 2.5 mm²)","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"5.5 ... 8 A","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/46cf26ec1c5e3af0bd268b3aa7908849.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=407192&mlfb=3RA2110-1HA15-1AP6"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2110-1HA15-1AP6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2110-1HA15-1AP6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}