{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2110-1HH15-1AP0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2110-1HH15-1AP0","canonicalUrl":"https://aoctrl.com/siemens/3RA2110-1HH15-1AP0","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2110-1HH15-1AP0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2110-1HH15-1AP0 direct-on-line motor starter, size S00, 3 kW at 400 V AC-3, Class 10, spring-loaded terminals, 45 mm wide, snaps onto 60 mm busbar systems.","salesMarkdown":"## 45 mm wide, snaps onto 60 mm busbars — not DIN rail The 3RA2110-1HH15-1AP0: This is a busbar-mounted direct-on-line starter, not a DIN-rail unit. The fastening method is for snapping onto 60 mm busbar systems. The supplied busbar adapter is part number 8US1251-5DT11. Width is 45 mm, height 260 mm, depth 155 mm. The 155 mm depth is the dimension that catches panel layouts — it's deeper than a standalone contactor because the overload relay and link module sit behind the contactor on the busbar adapter. Clearance requirements: 50 mm upwards, 20 mm forwards, 10 mm downwards, 20 mm at the side, 0 mm backwards. Mounting position is vertical only. Rated motor power is 3 000 W at 400 V, 50/60 Hz. At 480 V the rated current is 8 A. This is standard for general-purpose motor starting — not for high-inertia loads like large fans or centrifuges that need Class 20 or 30. ## Supplied as a kit — contactor, link module, busbar adapter The starter ships as a pre-assembled kit: contactor 3RT2015-2AP01, link module 3RA2911-2AA00, and busbar adapter 8US1251-5DT11. The contactor switching contact is electromechanical. Main circuit terminals are spring-loaded — push-in wiring for solid or ferruled stranded conductors. No screw torque to verify, which saves time on repetitive builds. Overload release design is thermal bimetallic. The circuit-breaker size is S00, matching the load feeder size. ## Active production — no phase-out signal Operating temperature range is -20 to +60 °C with temperature compensation across the same range. Storage and transport range is -50 to +80 °C. Substance prohibitance date is 10/01/2009 — the part complies with RoHS substance restrictions as of that date.","metaTitle":"Siemens 3RA2110-1HH15-1AP0 SIRIUS Motor Starter","metaDescription":"Siemens SIRIUS 3RA2110-1HH15-1AP0 direct-on-line starter, 3 kW at 400 V AC-3, Class 10, snaps onto 60 mm busbars. Spring-loaded terminals.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Starters"],"specifications":{"Depth":"155 mm","Width":"45 mm","title":"3RA2110-1HH15-1AP0","Height":"260 mm","Upwards":"50 mm","Forwards":"20 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"20 mm","Rated Value":"690 V","description":"Load feeder fuseless, Direct-on-line starting 400 V AC, Size S00 5.50...8.00 A 230 V AC Spring-type terminal for 60 mm busbar systems Type of coordination 1, Iq = 150 kA 1 NO (contactor)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"for snapping onto 60 mm busbar systems","Mounting Position":"vertical","PROFIsafe protocol":"No","Product Brand Name":"SIRIUS","Type Of Assignment":"1","Product Designation":"Direct (on-line) starter","Size Of Load Feeder":"S00","PROFINET IO protocol":"No","at 400 V rated value":"3 000 W","at 480 V rated value":"8 A","at 50 Hz rated value":"230 ... 230 V","at 60 Hz rated value":"230 ... 230 V","Design Of The Product":"for 60 mm busbars","For Main Current Circuit":"spring-loaded terminals","Temperature Compensation":"-20 ... +60 °C","at 220/230 V rated value":"2 hp","at 460/480 V rated value":"5 hp","at 575/600 V rated value":"5 hp","Of The Supplied Contactor":"3RT2015-2AP01","Of The Supplied Link Module":"3RA2911-2AA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","Substance Prohibitance (Date)":"10/01/2009","Design Of The Overload Release":"thermal (bimetallic)","Of The Supplied Busbar Adapter":"8US1251-5DT11","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-1HA20","degree of protection NEMA rating":"other","For Auxiliary And Control Circuit":"spring-loaded terminals","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Surge Voltage Resistance Rated Value":"6 kV","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","apparent holding power of magnet coil at AC":"4.2 VA","protocol is supported AS-Interface protocol":"No","with high demand rate according to SN 31920":"73 %","shock resistance according to IEC 60068-2-27":"6g / 11 ms","Type Of Voltage Of The Control Supply Voltage":"AC","at 400 V according to IEC 60947-4-1 rated value":"150 000 A","operational current at AC-3 at 400 V rated value":"6.5 A","Mechanical Service Life (Switching Cycles) Of Contactor Typical":"30 000 000","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"5.5 ... 8 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/757d211a5db0c02c3f1f20a940e1c1cf.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=106590&mlfb=3RA2110-1HH15-1AP0"},"ai":{"faq":[{"question":"What is 3RA2110-1HH15-1AP0's listed depth (155 mm) on this Motor Starters line?","answer":"The depth is 155 mm. This is the dimension that most often requires checking in a panel layout — it's deeper than a standalone contactor because the overload relay and link module sit behind the contactor on the busbar adapter."},{"question":"What is 3RA2110-1HH15-1AP0's listed width (45 mm) on this Motor Starters line?","answer":"The width is 45 mm. This is a single-module-wide footprint for a size S00 load feeder that includes the contactor, overload relay, and link module in one assembly."},{"question":"What compliance documentation does Siemens provide for 3RA2110-1HH15-1AP0 (RoHS, REACH, UL, IEC)?","answer":"The substance prohibitance date is 10/01/2009, indicating RoHS compliance as of that date. The product is part of the Siemens SIRIUS brand and carries the standard IEC/EN certifications for the series. Specific UL/CSA documentation is available from Siemens on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2110-1HH15-1AP0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2110-1HH15-1AP0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}