{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2110-1JD16-1AP6","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2110-1JD16-1AP6","canonicalUrl":"https://aoctrl.com/siemens/3RA2110-1JD16-1AP6","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2110-1JD16-1AP6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2 non-fused motor starter, direct starter design, size S00, CLASS 10 thermal overload, 4 kW at 400 V AC-3, 50/60 Hz, snap-on for 60 mm busbar systems.","salesMarkdown":"## What this SIRIUS 3RA2 non-fused motor starter delivers The Siemens 3RA2110-1JD16-1AP6 is a SIRIUS 3RA2 non-fused motor starter, assembled as a direct starter combining a contactor and a thermal bimetallic overload relay in one unit. It ships with the 3RT2016-1AP61 contactor, the 3RA1921-1DA00 link module, and the 8US1251-5DS10 busbar adapter — everything needed to snap onto a 60 mm busbar system and start a motor load. Rated for AC-3 duty up to 690 V, this size S00 feeder delivers 4 kW at 400 V (5 hp at 460/480 V, 7.5 hp at 575/600 V). The thermal bimetallic overload is field-adjustable and compensates for ambient temperature shifts across the -20 to +60 °C operating range. Pollution degree 3 (industrial environment) and a vertical-only mounting position are baked into the design; no derating needed when installed per the spec. Snaps directly onto 60 mm busbar systems via the supplied busbar adapter — no additional mounting plate needed. Dimensions are 45 mm wide, 200 mm high, 155.1 mm deep, fitting standard S00 feeder slots in Siemens SIRIUS panels. Clearance requirements: 20 mm upwards, 10 mm downwards, 9 mm at the side; zero clearance forwards or backwards. The link module pre-wires the contactor coil to the overload's N/C trip contact, so the starter drops out on overload without external interposing relays.","metaTitle":"Siemens 3RA2110-1JD16-1AP6 SIRIUS Non-Fused Motor Starter","metaDescription":"Siemens 3RA2110-1JD16-1AP6 SIRIUS non-fused motor starter, direct starter design, CLASS 10 trip, 4 kW at 400 V. Sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Starters"],"specifications":{"Depth":"155.1 mm","Width":"45 mm","title":"3RA2110-1JD16-1AP6","Height":"200 mm","Upwards":"20 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"690 V","description":"Fuseless motor starter Direct start 600VAC Size S00 7-10A 220/240VAC 50/60HZ screw connection For snapping onto 60 mm busbar systems Type of coordination 1 1NO (contactor)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-55 ... +80 °C","Fastening Method":"for snapping onto 60 mm busbar systems","Mounting Position":"vertical","Product Brand Name":"SIRIUS","Type Of Assignment":"1","Degree Of Pollution":"3","Product Designation":"non-fused motor starter 3RA2","Size Of Load Feeder":"S00","at 400 V rated value":"4 000 W","at 480 V rated value":"7.6 A","at 50 Hz rated value":"187 ... 242 V","at 500 V rated value":"5 500 W","at 60 Hz rated value":"192 ... 264 V","at 600 V rated value":"9 A","Design Of The Product":"direct starter","at 200/208 V rated value":"2 hp","at 220/230 V rated value":"3 hp","at 460/480 V rated value":"5 hp","at 575/600 V rated value":"7.5 hp","Of The Supplied Contactor":"3RT2016-1AP61","Of The Supplied Link Module":"3RA1921-1DA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","Design Of The Overload Release":"thermal (bimetallic)","Of The Supplied Busbar Adapter":"8US1251-5DS10","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-1JA10","Product Extension Auxiliary Switch":"Yes","Surge Voltage Resistance Rated Value":"6 kV","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","apparent holding power of magnet coil at AC":"4.8 VA","number of NO contacts for auxiliary contacts":"1","shock resistance according to IEC 60068-2-27":"6g / 11 ms","at 400 V according to IEC 60947-4-1 rated value":"153 000 A","operational current at AC-3 at 400 V rated value":"8.5 A","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","Inductive Power Factor With The Holding Power Of The Coil":"0.25","Mechanical Service Life (Operating Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"130 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Type Of Connectable Conductor Cross-Sections For Main Contacts Stranded":"0.5 ... 4 mm², 2x (0.75 ... 2.5 mm²)","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"7 ... 10 A","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1648be4ee177e14941d30262da0dad09.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=363688&mlfb=3RA2110-1JD16-1AP6"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2110-1JD16-1AP6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2110-1JD16-1AP6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}