{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2115-0ED15-1AP6","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2115-0ED15-1AP6","canonicalUrl":"https://aoctrl.com/siemens/3RA2115-0ED15-1AP6","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2115-0ED15-1AP6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2115-0ED15-1AP6 non-fused motor starter, direct starter design, size S00, Class 10 thermal overload, coil 187-264 V 50/60 Hz, 690 V rated insulation voltage.","salesMarkdown":"The Siemens 3RA2115-0ED15-1AP6 is a SIRIUS non-fused motor starter, built as a direct starter in size S00. It integrates a contactor, a thermal bimetallic overload relay, and a magnetic short-circuit trip into one assembly that snaps onto 60 mm busbar systems — a common panel layout for motor control centers. The supplied contactor is 3RT2015-1AP61, the link module is 3RA1921-1DA00, and the circuit-breaker is 3RV2011-0EA15; the busbar adapter 8US1251-5DS10 is also included, so the unit arrives as a ready-to-mount feeder. The coil accepts 187–242 V at 50 Hz and 192–264 V at 60 Hz, covering the common 208–240 V control supply range. Mounting position is vertical only, per the datasheet. The unit snaps onto 60 mm busbar systems — the standard spacing in Siemens SIRIUS MCCs and many third-party panel layouts. Dimensions are 200 mm high, 45 mm wide, and 155.1 mm deep. Clearance requirements: 20 mm upward, 10 mm downward, 9 mm at the side, zero forward or backward. That 45 mm width is a single 45 mm module, so it occupies one slot in a typical busbar grid. Wire sizing for main contacts: stranded 0.5–4 mm², or 2×(0.75–2.5 mm²). AWG equivalents are 2×(20–16), with a note that only the contactor side accepts 2×(18–14) and 2×12. The product extension for an auxiliary switch is available, so you can add a feedback contact for PLC status monitoring without modifying the main assembly. ## Environmental and Duty Ratings Operating temperature range is –20 to +60 °C; storage is –50 to +80 °C; transport range is –55 to +80 °C. Type of assignment is 2, which means Type 2 coordination: under a short-circuit fault, the starter remains operational after clearing the fault — no replacement of the contactor or overload relay required. That is a key specification for production lines where downtime for component swap is unacceptable.","metaTitle":"Siemens 3RA2115-0ED15-1AP6 SIRIUS Non-Fused Motor Starter","metaDescription":"Siemens SIRIUS 3RA2115-0ED15-1AP6 non-fused motor starter, direct starter design, Class 10 trip, coil 187-264 V 50/60 Hz. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Starters"],"specifications":{"Depth":"155.1 mm","Width":"45 mm","Height":"200 mm","Upwards":"20 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"690 V","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-55 ... +80 °C","Fastening Method":"for snapping onto 60 mm busbar systems","Mounting Position":"vertical","Product Brand Name":"SIRIUS","Type Of Assignment":"2","Degree Of Pollution":"3","Product Designation":"non-fused motor starter 3RA2","Size Of Load Feeder":"S00","at 400 V rated value":"90 W","at 50 Hz rated value":"187 ... 242 V","at 500 V rated value":"120 W","at 60 Hz rated value":"192 ... 264 V","at 690 V rated value":"180 W","Design Of The Product":"direct starter","Of The Supplied Contactor":"3RT2015-1AP61","For Main Contacts Stranded":"0.5 ... 4 mm², 2x (0.75 ... 2.5 mm²)","Of The Supplied Link Module":"3RA1921-1DA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","Design Of The Overload Release":"thermal (bimetallic)","Of The Supplied Busbar Adapter":"8US1251-5DS10","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","at AWG cables for main contacts":"2x (20 ... 16), only for contactor 2x (18 ... 14), 2x 12","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-0EA15","Product Extension Auxiliary Switch":"Yes","Surge Voltage Resistance Rated Value":"6 kV","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","apparent holding power of magnet coil at AC":"4.8 VA","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"2","shock resistance according to IEC 60068-2-27":"6g / 11 ms","at 400 V according to IEC 60947-4-1 rated value":"153 000 A","at 500 V according to IEC 60947-4-1 rated value":"100 000 A","at 690 V according to IEC 60947-4-1 rated value":"100 000 A","operational current at AC-3 at 400 V rated value":"0.3 A","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","Inductive Power Factor With The Holding Power Of The Coil":"0.25","Mechanical Service Life (Switching Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"5.2 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.28 ... 0.4 A","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=120079&mlfb=3RA2115-0ED15-1AP6","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RA2115-0ED15-1AP6/alternatives.json"},"ai":{"faq":[{"question":"What is the rated current range of 3RA2115-0ED15-1AP6?","answer":"The evidence does not list a specific rated current range for this order code. The overload relay is thermal bimetallic and Class 10; the circuit-breaker supplied is 3RV2011-0EA15. For the exact setting range, refer to the datasheet for that breaker."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2115-0ED15-1AP6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2115-0ED15-1AP6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}