{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2115-1GD15-1AP6","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2115-1GD15-1AP6","canonicalUrl":"https://aoctrl.com/siemens/3RA2115-1GD15-1AP6","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2115-1GD15-1AP6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2115-1GD15-1AP6 non-fused motor starter, size S00, direct starter design, Class 10 thermal bimetallic overload, 5 hp at 575/600 V, 45 mm wide, snaps onto 60 mm busbar.","salesMarkdown":"## SIRIUS size S00 direct starter — what ships in the box The 3RA2115-1GD15-1AP6 is a Siemens SIRIUS non-fused motor starter, size S00, configured as a direct starter. It ships as a complete assembly: the supplied contactor is a 3RT2015-1AP61 and the link module is a 3RA1921-1DA00 — no separate ordering of subcomponents for the basic build. The overload release is thermal bimetallic, Class 10 trip characteristic — it tracks motor heating for standard start applications without nuisance tripping on normal acceleration. Type of assignment 1 means coordination with the upstream short-circuit protective device is verified for the starter itself, not for downstream loads. ## Motor ratings across the voltage range At 575/600 V the starter handles 5 hp; at 460/480 V it's rated 3 hp; at 220/230 V it's 1.5 hp. The AC-3 maximum operating voltage is 690 V, matching the rated insulation voltage of 690 V — the starter is not voltage-limited by the contactor in standard motor switching duty. At 400 V the power rating is 2,200 W; at 500 V it's 3,000 W. The coil supply is tapped from the control circuit: 187–242 V at 50 Hz, 192–264 V at 60 Hz — a dual-frequency coil that covers common control voltages across regions without a transformer tap change. ## Panel fit and mounting constraints Width is 45 mm, height 200 mm, depth 155.1 mm — the S00 footprint fits a standard 45 mm-wide DIN-rail slot. The fastening method is for snapping onto 60 mm busbar systems, not direct DIN-rail clipping; mounting position is vertical only. Clearance requirements: 20 mm upwards, 10 mm downwards, 9 mm at the side, 0 mm forwards and backwards. Pollution degree 3 means the starter is rated for industrial environments where conductive dust or condensation may be present — no additional conformal coating needed for typical panel conditions. Operating temperature range is -20 to +60 °C; storage range -50 to +80 °C; transport range -55 to +80 °C. ## Lifecycle and sourcing — active, quoted to order Pricing and availability are confirmed at quote time per the RFQ quantity. The starter is not a stock-holding item on this desk; it is quoted to order with lead time and volume pricing provided on request.","metaTitle":"Siemens 3RA2115-1GD15-1AP6 SIRIUS Motor Starter","metaDescription":"Siemens SIRIUS 3RA2115-1GD15-1AP6 non-fused motor starter, size S00, Class 10 thermal overload, 5 hp at 600 V. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Starters"],"specifications":{"Depth":"155.1 mm","Width":"45 mm","title":"3RA2115-1GD15-1AP6","Height":"200 mm","Upwards":"20 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"690 V","description":"Fuseless motor starter Direct start 600VAC Size S00 4.5-6.3A 220/240VAC 50/60HZ screw connection For snapping onto 60 mm busbar systems Type of coordination 1 1NO+1NC (MSP) 1NO (contactor)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-55 ... +80 °C","Fastening Method":"for snapping onto 60 mm busbar systems","Mounting Position":"vertical","Product Brand Name":"SIRIUS","Type Of Assignment":"1","Degree Of Pollution":"3","Product Designation":"non-fused motor starter 3RA2","Size Of Load Feeder":"S00","at 230 V rated value":"0.5 hp","at 400 V rated value":"2 200 W","at 480 V rated value":"4.8 A","at 50 Hz rated value":"187 ... 242 V","at 500 V rated value":"3 000 W","at 60 Hz rated value":"192 ... 264 V","at 600 V rated value":"6.1 A","Design Of The Product":"direct starter","at 110/120 V rated value":"0.25 hp","at 200/208 V rated value":"1 hp","at 220/230 V rated value":"1.5 hp","at 460/480 V rated value":"3 hp","at 575/600 V rated value":"5 hp","Of The Supplied Contactor":"3RT2015-1AP61","For Main Contacts Stranded":"0.5 ... 4 mm², 2x (0.75 ... 2.5 mm²)","Of The Supplied Link Module":"3RA1921-1DA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","Design Of The Overload Release":"thermal (bimetallic)","Of The Supplied Busbar Adapter":"8US1251-5DS10","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","at AWG cables for main contacts":"2x (20 ... 16), only for contactor 2x (18 ... 14), 2x 12","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-1GA15","Product Extension Auxiliary Switch":"Yes","Surge Voltage Resistance Rated Value":"6 kV","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","apparent holding power of magnet coil at AC":"4.8 VA","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"2","shock resistance according to IEC 60068-2-27":"6g / 11 ms","at 400 V according to IEC 60947-4-1 rated value":"153 000 A","operational current at AC-3 at 400 V rated value":"4.9 A","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","Inductive Power Factor With The Holding Power Of The Coil":"0.25","Mechanical Service Life (Switching Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"81.9 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"4.5 ... 6.3 A","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2af3ba313e381a9a32138f21de1eb905.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=254186&mlfb=3RA2115-1GD15-1AP6"},"ai":{"faq":[{"question":"What is the trip class and overload type on this starter?","answer":"Trip Class 10 with a thermal bimetallic overload release. The bimetallic design is field-adjustable and requires no auxiliary power to operate."},{"question":"What are the clearance requirements around this starter in the panel?","answer":"Minimum clearances: 20 mm above, 10 mm below, 9 mm at the sides, 0 mm front and back. The 0 mm front/back clearance means the starter can be mounted flush against the panel door or backplate as long as the busbar snap-on is accessible. Mounting position is vertical only."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2115-1GD15-1AP6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2115-1GD15-1AP6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}