{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2115-1HA16-1AP6","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2115-1HA16-1AP6","canonicalUrl":"https://aoctrl.com/siemens/3RA2115-1HA16-1AP6","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2115-1HA16-1AP6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2115-1HA16-1AP6 non-fused direct motor starter, size S00, Class 10, 3 hp at 400 V, 690 V AC-3, snap-on DIN rail.","salesMarkdown":"## SIRIUS non-fused direct starter — what lands in the panel The 3RA2115-1HA16-1AP6 is a SIRIUS non-fused direct starter, size S00, combining a contactor (3RT2016-1AP61), a link module (3RA1921-1DA00), and a circuit-breaker in a single assembly. It ships as a factory-matched unit — no separate coordination work on site. Rated 3 hp at 400 V (3 000 W) and 5 hp at 460/480 V, with a maximum AC-3 switching voltage of 690 V. ## Mounting and panel fit — DIN rail or screw Mounting position is vertical only. Dimensions: 45 mm wide, 167.2 mm high, 97.1 mm deep — the S00 footprint fits a standard 45 mm slot on the rail. Clearance requirements: 20 mm upwards, 10 mm downwards, 9 mm at the side, zero forwards and backwards. These are the minimum air gaps needed around the enclosure for cable entry and heat dissipation — factor them into the panel layout before the gland plate is drilled. ## Wiring and environmental limits This covers the typical 1.5 mm² or 2.5 mm² motor cables for a 3 hp load at 400 V. Operates from -20 to +60 °C ambient, stores from -50 to +80 °C. Pollution degree 3 (conductive pollution or dry non-conductive pollution that becomes conductive due to condensation) — suitable for control panels in industrial environments without climate control. ## Lifecycle and supply posture Supplied through independent distribution channels. No minimum order quantity beyond the single unit for sample or emergency replacement.","metaTitle":"Siemens 3RA2115-1HA16-1AP6 SIRIUS Motor Starter","metaDescription":"Siemens 3RA2115-1HA16-1AP6 SIRIUS non-fused direct starter, size S00, Class 10. Rated 3 hp at 400 V, 690 V AC-3. Active production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Starters"],"specifications":{"Depth":"97.1 mm","Width":"45 mm","title":"3RA2115-1HA16-1AP6","Height":"167.2 mm","Upwards":"20 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"690 V","description":"Fuseless motor starter Direct start 600VAC Size S00 5.5-8Amp 220/240VAC 50/60HZ screw connection For screw mounting Or 35 mm rail-mounting Type of coordination 1 1NO+1NC (MSP) 1NO (contactor)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-55 ... +80 °C","Fastening Method":"Snap-mounted to DIN rail or screw-mounted with additional push-in lug","Mounting Position":"vertical","Product Brand Name":"SIRIUS","Type Of Assignment":"1","Degree Of Pollution":"3","Product Designation":"non-fused motor starter 3RA2","Size Of Load Feeder":"S00","at 230 V rated value":"1 hp","at 400 V rated value":"3 000 W","at 480 V rated value":"7.6 A","at 50 Hz rated value":"187 ... 242 V","at 500 V rated value":"4 000 W","at 60 Hz rated value":"192 ... 264 V","at 600 V rated value":"6.33 A","at 690 V rated value":"5 500 W","Design Of The Product":"direct starter","at 110/120 V rated value":"0.33 hp","at 200/208 V rated value":"2 hp","at 220/230 V rated value":"2 hp","at 460/480 V rated value":"5 hp","at 575/600 V rated value":"5 hp","Of The Supplied Contactor":"3RT2016-1AP61","For Main Contacts Stranded":"0.5 ... 4 mm², 2x (0.75 ... 2.5 mm²)","Of The Supplied Link Module":"3RA1921-1DA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","Design Of The Overload Release":"thermal (bimetallic)","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","at AWG cables for main contacts":"2x (20 ... 16), only for contactor 2x (18 ... 14), 2x 12","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-1HA15","Product Extension Auxiliary Switch":"Yes","Surge Voltage Resistance Rated Value":"6 kV","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","apparent holding power of magnet coil at AC":"4.8 VA","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"2","shock resistance according to IEC 60068-2-27":"6g / 11 ms","at 400 V according to IEC 60947-4-1 rated value":"153 000 A","operational current at AC-3 at 400 V rated value":"6.5 A","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","Inductive Power Factor With The Holding Power Of The Coil":"0.25","Mechanical Service Life (Switching Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"104 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"5.5 ... 8 A","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ea9a7fc805723fd73c498623f5584139.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=512429&mlfb=3RA2115-1HA16-1AP6"},"ai":{"faq":[{"question":"What are the key electrical ratings for 3RA2115-1HA16-1AP6?","answer":"Rated 3 hp at 400 V (3 000 W), 5 hp at 460/480 V, and 5 500 W at 690 V. The maximum AC-3 switching voltage is 690 V. Trip class 10 overload protection. Horsepower ratings also cover 1 hp at 230 V and 0.33 hp at 110/120 V."},{"question":"What compliance documentation does Siemens provide for 3RA2115-1HA16-1AP6?","answer":"As a standard SIRIUS catalogue product, it carries CE marking for the European market and is designed to IEC/EN 60947 series standards. RoHS and REACH compliance declarations are available from Siemens documentation. The unit is UL/CSA listed under the SIRIUS range — confirm the specific UL file number for your jurisdiction at RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2115-1HA16-1AP6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2115-1HA16-1AP6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}