{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2115-1JD16-1AP6","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2115-1JD16-1AP6","canonicalUrl":"https://aoctrl.com/siemens/3RA2115-1JD16-1AP6","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2115-1JD16-1AP6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2115-1JD16-1AP6 non-fused motor starter, size S00, direct starter, Class 10, 7.5 hp at 575/600 V, 45 mm width, 200 mm height, 155.1 mm depth.","salesMarkdown":"The 3RA2115-1JD16-1AP6: This is a SIRIUS non-fused motor starter, size S00, configured as a direct starter — meaning it combines a contactor and a thermal bimetallic overload relay in one assembly, ready to snap onto a 60 mm busbar system. The operating frequency covers 50 to 60 Hz, with coil voltage ranges 187–242 V at 50 Hz and 192–264 V at 60 Hz. ## Mounting and panel fit Fastening method is for snapping onto 60 mm busbar systems — no DIN-rail adapter needed if the panel uses standard 60 mm busbar. Mounting position is vertical only. Dimensions: 45 mm wide, 200 mm high, 155.1 mm deep. Clearance required: 20 mm upwards, 10 mm downwards, 9 mm at the side. No forward or backward clearance needed. ## Supplied sub-assemblies — what arrives in the box The starter ships with the contactor 3RT2016-1AP61, the link module 3RA1921-1DA00, and the busbar adapter 8US1251-5DS10. The overload release is thermal bimetallic, electromechanical switching contacts.","metaTitle":"Siemens 3RA2115-1JD16-1AP6 SIRIUS Motor Starter","metaDescription":"Siemens 3RA2115-1JD16-1AP6 SIRIUS non-fused motor starter, size S00, direct starter, Class 10, 7.5 hp at 575/600 V. Active production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Starters"],"specifications":{"Depth":"155.1 mm","Width":"45 mm","title":"3RA2115-1JD16-1AP6","Height":"200 mm","Upwards":"20 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"690 V","description":"Fuseless motor starter Direct start 600VAC Size S00 7-10A 220/240VAC 50/60HZ screw connection For snapping onto 60 mm busbar systems Type of coordination 1 1NO+1NC (MSP) 1NO (contactor)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-55 ... +80 °C","Fastening Method":"for snapping onto 60 mm busbar systems","Mounting Position":"vertical","Product Brand Name":"SIRIUS","Type Of Assignment":"1","Degree Of Pollution":"3","Product Designation":"non-fused motor starter 3RA2","Size Of Load Feeder":"S00","at 400 V rated value":"4 000 W","at 480 V rated value":"7.6 A","at 50 Hz rated value":"187 ... 242 V","at 500 V rated value":"5 500 W","at 60 Hz rated value":"192 ... 264 V","at 600 V rated value":"9 A","Design Of The Product":"direct starter","at 200/208 V rated value":"2 hp","at 220/230 V rated value":"3 hp","at 460/480 V rated value":"5 hp","at 575/600 V rated value":"7.5 hp","Of The Supplied Contactor":"3RT2016-1AP61","Of The Supplied Link Module":"3RA1921-1DA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","Design Of The Overload Release":"thermal (bimetallic)","Of The Supplied Busbar Adapter":"8US1251-5DS10","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-1JA15","Product Extension Auxiliary Switch":"Yes","Surge Voltage Resistance Rated Value":"6 kV","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","apparent holding power of magnet coil at AC":"4.8 VA","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"2","shock resistance according to IEC 60068-2-27":"6g / 11 ms","at 400 V according to IEC 60947-4-1 rated value":"153 000 A","operational current at AC-3 at 400 V rated value":"8.5 A","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","Inductive Power Factor With The Holding Power Of The Coil":"0.25","Mechanical Service Life (Operating Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"130 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Type Of Connectable Conductor Cross-Sections For Main Contacts Stranded":"0.5 ... 4 mm², 2x (0.75 ... 2.5 mm²)","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"7 ... 10 A","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c91485664ae86b52738c2f0b8129dc17.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=398654&mlfb=3RA2115-1JD16-1AP6"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3RA2115-1JD16-1AP6?","answer":"Submit an RFQ against your BOM quantity."},{"question":"What is the listed depth and width of 3RA2115-1JD16-1AP6?","answer":"Depth is 155.1 mm, width is 45 mm, height is 200 mm. Clearance required: 20 mm upwards, 10 mm downwards, 9 mm at the side."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2115-1JD16-1AP6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2115-1JD16-1AP6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}