{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2210-0CA15-2AP6","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2210-0CA15-2AP6","canonicalUrl":"https://aoctrl.com/siemens/3RA2210-0CA15-2AP6","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2210-0CA15-2AP6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2210-0CA15-2AP6 non-fused reversing motor starter, size S00, Class 10 thermal bimetallic overload, 690 V AC-3, 50-60 Hz, snap-on DIN rail.","salesMarkdown":"## SIRIUS S00 reversing starter — what's in the box The 3RA2210-0CA15-2AP6: This is a fully assembled non-fused reversing motor starter from the SIRIUS family, size S00. It ships with the 3RT2015-1AP62 contactor, the 3RV2011-0CA10 circuit-breaker, and the 3RA1921-1DA00 link module already integrated — one order code, one assembly, no separate sourcing of sub-components. That's the standard protection for standard-duty squirrel-cage motors — not for high-inertia loads that need Class 20 or longer. Rated insulation voltage is 690 V, and the maximum AC-3 switching voltage is also 690 V, so it covers 400 V, 480 V, and 575 V motor feeders without derating. The operating frequency is 50-60 Hz, which is the global norm for industrial mains. ## Panel fit — S00 frame dimensions and clearances The starter measures 170 mm high, 90 mm wide, and 97.1 mm deep. That's the standard S00 footprint — it shares the same mounting hole pattern and DIN-rail clip as other S00 SIRIUS devices, so swapping in a different S00 starter or contactor doesn't require re-drilling the backplate. Clearance requirements: 20 mm upwards, 10 mm downwards, 9 mm at the sides, and zero forwards or backwards. That 9 mm side gap is tight — adjacent devices with side-mounted aux blocks may need more. AWG equivalents are 2x (20-16) for the contactor, and 2x (18-14) or 2x 12 for the circuit-breaker side. The terminal design accepts ferruled stranded or solid conductors — no special crimp tool needed beyond standard ferrule dies. ## Lifecycle and sourcing — current production, no cross-reference needed Compliance: RoHS substance prohibition date is 03/01/2017, which covers the EU RoHS 2 (2011/65/EU) and the updated RoHS 3 (2015/863) scope. The starter carries the CE mark and is designed to IEC/EN 60947-4-1 for motor starters and IEC/EN 60947-2 for the integrated circuit-breaker.","metaTitle":"Siemens 3RA2210-0CA15-2AP6 SIRIUS Reversing Motor Starter","metaDescription":"Siemens 3RA2210-0CA15-2AP6 SIRIUS reversing motor starter, size S00, Class 10 thermal overload, 690 V, 50-60 Hz. Current production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Starters"],"specifications":{"Depth":"97.1 mm","Width":"90 mm","title":"3RA2210-0CA15-2AP6","Height":"170 mm","Upwards":"20 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"690 V","description":"FUSELESS MOTOR STARTER REVERSING OPERATION 600V AC SZ S00 0.18-0.25A 220/240V AC 50/60HZ SCREW CONNECTION FOR SCREW MOUNTING OR 35 MM RAIL-MOUNTING TYPE OF COORDINATION 2 IQ = 150 KA ALSO FULFILLS TYPE OF COORDINATION 1 1NC (PER CONTACTOR)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-55 ... +80 °C","Fastening Method":"Snap-mounted to DIN rail or screw-mounted with additional push-in lug","Mounting Position":"vertical","Product Brand Name":"SIRIUS","Type Of Assignment":"2","Degree Of Pollution":"3","Product Designation":"non-fused motor starter 3RA2","Size Of Load Feeder":"S00","at 400 V rated value":"60 W","at 50 Hz rated value":"187 ... 242 V","at 500 V rated value":"90 W","at 60 Hz rated value":"192 ... 264 V","at 690 V rated value":"120 W","Design Of The Product":"reversing starter","Of The Supplied Contactor":"3RT2015-1AP62","For Main Contacts Stranded":"0.5 ... 4 mm², 2x (0.75 ... 2.5 mm²)","Of The Supplied Link Module":"3RA1921-1DA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","Substance Prohibitance (Date)":"03/01/2017","Design Of The Overload Release":"thermal (bimetallic)","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","at AWG cables for main contacts":"2x (20 ... 16), only for contactor 2x (18 ... 14), 2x 12","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-0CA10","Product Extension Auxiliary Switch":"Yes","Surge Voltage Resistance Rated Value":"6 kV","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","apparent holding power of magnet coil at AC":"4.8 VA","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"0","shock resistance according to IEC 60068-2-27":"6g / 11 ms","at 400 V according to IEC 60947-4-1 rated value":"153 000 A","at 500 V according to IEC 60947-4-1 rated value":"100 000 A","at 690 V according to IEC 60947-4-1 rated value":"100 000 A","operational current at AC-3 at 400 V rated value":"0.2 A","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","Inductive Power Factor With The Holding Power Of The Coil":"0.25","Mechanical Service Life (Switching Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"3.25 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.18 ... 0.25 A","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/aaeb92f9b1d554b7f9e2abb0ac784db4.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=519954&mlfb=3RA2210-0CA15-2AP6"},"ai":{"faq":[{"question":"What is the Trip Class of this motor starter?","answer":"This is the standard protection for general-purpose squirrel-cage motors under normal starting duty."},{"question":"What are the mounting clearances for the 3RA2210-0CA15-2AP6?","answer":"Minimum clearances: 20 mm above, 10 mm below, 9 mm at the sides, and zero forwards or backwards. Mounting position is vertical only, on a 35 mm DIN rail or with screw-mount using the push-in lug."},{"question":"What compliance documentation does Siemens provide for this starter?","answer":"The RoHS substance prohibition date is 03/01/2017, covering EU RoHS 2 and RoHS 3. The starter is designed to IEC/EN 60947-4-1 (motor starters) and IEC/EN 60947-2 (circuit-breaker), and carries CE marking."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2210-0CA15-2AP6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2210-0CA15-2AP6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}