{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2210-0DA15-2AK6","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2210-0DA15-2AK6","canonicalUrl":"https://aoctrl.com/siemens/3RA2210-0DA15-2AK6","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2210-0DA15-2AK6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2210-0DA15-2AK6 non-fused reversing load feeder, size S00, CLASS 10 thermal bimetallic overload, 3-pole, 690 V max, screw and snap-on 35 mm DIN rail.","salesMarkdown":"## Reversing starter in a single assembly The 3RA2210-0DA15-2AK6 is a SIRIUS non-fused reversing load feeder — a reversing starter that packages the contactor pair, overload relay, and circuit-breaker into one DIN-rail-mounted unit. Size S00 frame keeps the footprint tight: 90 mm wide, 170 mm tall, 97.1 mm deep. Mounts vertically on 35 mm DIN rail with screw and snap-on fastening — no adapter plate needed for a standard panel layout. ## Trip class and overload protection The magnetic short-circuit trip handles the instantaneous fault side. The control supply is 110 V at 50 Hz or 120 V at 60 Hz — confirm the coil voltage matches your control transformer tap. ## What ships in the carton — no holes in the box This is a fully assembled reversing starter, not a pile of loose components. The supplied contactor (3RT2015-1AK62), link module (3RA1921-1DA00), and circuit-breaker (3RV2011-0DA10) are factory-integrated. The auxiliary switch extension is already provisioned (product extension auxiliary switch: Yes), so adding a spare contact block later doesn't require rewiring the main power path. Clearance dimensions are specified: 20 mm upwards, 10 mm downwards, 9 mm at the side, 0 mm forwards and backwards. That means the unit can sit flush against the backplane or enclosure door — no extra breathing space required on the Z-axis. ## Lifecycle and sourcing Sourced through independent distribution channels. Compliance documentation includes RoHS (substance prohibitance date 10/01/2009) and the standard IEC/UL certifications expected for a SIRIUS load feeder.","metaTitle":"Siemens 3RA2210-0DA15-2AK6 SIRIUS Reversing Starter, S00","metaDescription":"Siemens 3RA2210-0DA15-2AK6 SIRIUS non-fused reversing motor starter, size S00, CLASS 10 thermal overload, 690 V max. Active production, sourced per RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Starters"],"specifications":{"Depth":"97.1 mm","Width":"90 mm","title":"3RA2210-0DA15-2AK6","Height":"170 mm","Upwards":"20 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"690 V","description":"FUSELESS LOAD FEEDER REVERSING OPERATION, 400 V AC, S00 0.22 TO 0.32 A 3 KW, 110/120 V AC 50/60 HZ SCREW TERMINAL FOR STANDARD RAIL MOUNTING, TYPE OF COORDINATION 2, IQ = 150 KA (ALSO FULFILLS TYPE OF COORDINATION 1) 1NC (CONTACTOR)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail","Mounting Position":"vertical","Product Brand Name":"SIRIUS","Type Of Assignment":"2","Degree Of Pollution":"3","Product Designation":"non-fused load feeders 3RA2","Size Of Load Feeder":"S00","at 400 V rated value":"90 W","at 50 Hz rated value":"110 V","at 500 V rated value":"90 W","at 60 Hz rated value":"120 V","at 690 V rated value":"120 W","Design Of The Product":"reversing starter","Of The Supplied Contactor":"3RT2015-1AK62","Of The Supplied Link Module":"3RA1921-1DA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","Substance Prohibitance (Date)":"10/01/2009","Design Of The Overload Release":"thermal (bimetallic)","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-0DA10","Product Extension Auxiliary Switch":"Yes","Surge Voltage Resistance Rated Value":"6 kV","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","apparent holding power of magnet coil at AC":"4.2 VA","shock resistance according to IEC 60068-2-27":"6g / 11 ms","at 400 V according to IEC 60947-4-1 rated value":"153 000 A","at 500 V according to IEC 60947-4-1 rated value":"100 000 A","at 690 V according to IEC 60947-4-1 rated value":"100 000 A","operational current at AC-3 at 400 V rated value":"0.3 A","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","Mechanical Service Life (Operating Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"4.16 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Type Of Connectable Conductor Cross-Sections For Main Contacts Stranded":"0.5 ... 4 mm², 2x (0.75 ... 2.5 mm²)","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.22 ... 0.32 A","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c4db1190d167c4492b242e99ad029a48.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=229710&mlfb=3RA2210-0DA15-2AK6"},"ai":{"faq":[{"question":"What is the depth of 3RA2210-0DA15-2AK6?","answer":"The depth is 97.1 mm. Combined with 90 mm width and 170 mm height, it fits a standard S00 footprint on 35 mm DIN rail with zero forwards/backwards clearance needed."},{"question":"Will 3RA2210-0DA15-2AK6 replace a 6ES7214-1BG40-0XB0 in a panel?","answer":"No. The 6ES7214-1BG40-0XB0 is a Siemens S7-1200 PLC CPU, not a motor starter. They are different product classes with different wiring, power, and communication requirements — no direct drop-in replacement is possible."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2210-0DA15-2AK6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2210-0DA15-2AK6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}