{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2210-0ED15-2AP6","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2210-0ED15-2AP6","canonicalUrl":"https://aoctrl.com/siemens/3RA2210-0ED15-2AP6","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2210-0ED15-2AP6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2210-0ED15-2AP6 non-fused reversing motor starter, size S00, Trip Class 10, 690 V rated insulation voltage, 50/60 Hz, 90 mm width, 155.1 mm depth, 200 mm height.","salesMarkdown":"## Reversing starter, size S00 — what you get in the box The 3RA2210-0ED15-2AP6: This is a fully assembled non-fused reversing motor starter from the SIRIUS 3RA2 family, size S00. It ships with the supplied contactor (3RT2015-1AP62), link module (3RA1921-1DA00), busbar adapter (8US1251-5DS10), and RS assembly kit (3RA2913-1DB1) — everything needed to drop into a panel without sourcing sub-components separately. The reversing configuration means two contactors interlocked for forward/reverse motor direction control, with a single thermal overload relay (bimetallic) covering both directions. ## 690 V rated insulation, AC-3 duty to 690 V Rated insulation voltage is 690 V, with AC-3 switching rated to the same 690 V maximum. This covers 400 V and 690 V industrial networks without derating — common in European panel builds where the line-to-line voltage at the motor terminals can hit 690 V on a 400/690 V supply. Operating frequency is 50/60 Hz, with the coil rated 187–242 V at 50 Hz and 192–264 V at 60 Hz. The voltage tolerance covers standard European (230 V) and North American (240 V) control circuits within the same device. Thermal overload release is bimetallic — adjustable, resettable, and matched to the motor full-load current. The short-circuit trip is magnetic, so instantaneous protection on hard faults while the thermal element handles sustained overloads. ## Snap-on busbar mounting, vertical only Fastening method is designed for snapping onto 60 mm busbar systems — the standard Siemens SIRIUS mounting rail for distributing three-phase power across multiple feeders. No DIN rail required; the busbar adapter (supplied) clips directly onto the 60 mm flat busbar. Mounting position is vertical only — the bimetallic overload relay relies on natural convection for accurate tripping, so horizontal or inverted mounting will shift the trip curve. Envelope dimensions are 155.1 mm deep, 90 mm wide, 200 mm tall, with 20 mm clearance needed above and 10 mm below for wiring and heat dissipation. AWG equivalents are 2×(20–16) or 2×(18–14) plus 2×12. The terminal layout is standard for size S00 — screw-clamp with wire entry from the front. Sourced through authorized distribution channels. No minimum order threshold beyond the standard distributor MOQ.","metaTitle":"Siemens 3RA2210-0ED15-2AP6 SIRIUS Reversing Starter","metaDescription":"Siemens 3RA2210-0ED15-2AP6 non-fused reversing motor starter, SIRIUS 3RA2, size S00, Trip Class 10, 690 V, 50/60 Hz. Active production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Starters"],"specifications":{"Depth":"155.1 mm","Width":"90 mm","title":"3RA2210-0ED15-2AP6","Height":"200 mm","Upwards":"20 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"690 V","description":"FUSELESS MOTOR STARTER REVERSING OPERATION 600V AC SZ S00 0.28-0.4A 220/240V AC 50/60HZ SCREW CONNECTION FOR SNAPPING ONTO 60 MM BUSBAR SYSTEMS TYPE OF COORDINATION 2 IQ = 150 KA ALSO FULFILLS TYPE OF COORDINATION 1 1NC (PER CONTACTOR)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-55 ... +80 °C","Fastening Method":"for snapping onto 60 mm busbar systems","Mounting Position":"vertical","Product Brand Name":"SIRIUS","Type Of Assignment":"2","Degree Of Pollution":"3","Product Designation":"non-fused motor starter 3RA2","Size Of Load Feeder":"S00","at 400 V rated value":"90 W","at 50 Hz rated value":"187 ... 242 V","at 500 V rated value":"120 W","at 60 Hz rated value":"192 ... 264 V","at 690 V rated value":"180 W","Design Of The Product":"reversing starter","Of The Supplied Contactor":"3RT2015-1AP62","For Main Contacts Stranded":"0.5 ... 4 mm², 2x (0.75 ... 2.5 mm²)","Of The Supplied Link Module":"3RA1921-1DA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","Substance Prohibitance (Date)":"03/01/2017","Design Of The Overload Release":"thermal (bimetallic)","Of The Supplied Busbar Adapter":"8US1251-5DS10","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","at AWG cables for main contacts":"2x (20 ... 16), only for contactor 2x (18 ... 14), 2x 12","of the supplied RS assembly kit":"3RA2913-1DB1","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-0EA10","Product Extension Auxiliary Switch":"Yes","Surge Voltage Resistance Rated Value":"6 kV","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","apparent holding power of magnet coil at AC":"4.8 VA","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"0","shock resistance according to IEC 60068-2-27":"6g / 11 ms","at 400 V according to IEC 60947-4-1 rated value":"153 000 A","at 500 V according to IEC 60947-4-1 rated value":"100 000 A","at 690 V according to IEC 60947-4-1 rated value":"100 000 A","operational current at AC-3 at 400 V rated value":"0.3 A","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","Inductive Power Factor With The Holding Power Of The Coil":"0.25","Mechanical Service Life (Switching Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"5.2 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.28 ... 0.4 A","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/62f44b31964883bb97a4e2248ef93b36.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=440222&mlfb=3RA2210-0ED15-2AP6"},"ai":{"faq":[{"question":"What is the depth of 3RA2210-0ED15-2AP6?","answer":"Listed depth is 155.1 mm, width 90 mm, height 200 mm. Clearance required: 20 mm above, 10 mm below, 9 mm at the side."},{"question":"What compliance documentation does Siemens provide for this starter?","answer":"Degree of pollution is 3 (conductive pollution or dry non-conductive pollution that becomes conductive due to condensation). Full CE/UKCA declarations are available from Siemens."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2210-0ED15-2AP6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2210-0ED15-2AP6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}