{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2210-0EE15-2BB4","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2210-0EE15-2BB4","canonicalUrl":"https://aoctrl.com/siemens/3RA2210-0EE15-2BB4","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2210-0EE15-2BB4","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2210-0EE15-2BB4 reversing starter, size S00, 0.4 A AC-3 at 400 V, CLASS 10 trip, 24 V DC coil, screw and snap-on DIN rail mounting, spring-loaded terminals.","salesMarkdown":"## Form factor and panel fit — 90 × 97 × 204 mm The 3RA2210-0EE15-2BB4: Width 90 mm, depth 97 mm, height 204 mm — this reversing starter takes one standard S00-width slot on 35 mm DIN rail. The mounting method is screw and snap-on, so it clips onto the rail and can be screw-fixed for vibration resistance. Clearance envelope: 50 mm upward, 32 mm forward, 10 mm downward, 10 mm at the side, 0 mm backward. That backward-zero means the unit sits flush against the backplane — no extra gutter depth needed behind the rail. ## Motor duty and protection — CLASS 10, 0.4 A AC-3 The short-circuit trip is magnetic, so it clears hard faults fast without waiting on the thermal element. Coil is 24 V DC, common for PLC-driven reversing contactor groups. ## Termination and wiring — spring-loaded main circuit Main current circuit terminates with spring-loaded terminals — no screw torque to verify, no re-torquing on thermal cycles. The supplied contactor is 3RT2015-2BB42, and the link module is 3RA2911-2AA00, so the reversing interlock is pre-assembled. Operating temperature range -20 to +60 °C, storage -50 to +80 °C. ## Sourcing — current production, quoted to order Lifecycle stage is current production — this reversing starter is an active Siemens catalog item. Sourced through authorized distribution channels. Availability and current pricing confirmed against your BOM quantity at RFQ time.","metaTitle":"Siemens 3RA2210-0EE15-2BB4 reversing starter, S00","metaDescription":"Siemens SIRIUS 3RA2210-0EE15-2BB4 reversing starter, size S00, 0.4 A at 400 V AC-3, CLASS 10, 24 V DC coil. Current production — sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Starters"],"specifications":{"Depth":"97 mm","Width":"90 mm","title":"3RA2210-0EE15-2BB4","Height":"204 mm","Upwards":"50 mm","Forwards":"32 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"10 mm","Rated Value":"24 ... 24 V","description":"Load feeder fuseless, Reversing duty 400 V AC, Size S00 0.28...0.40 A 24 V DC Spring-type terminal for installation on standard mounting rail (also fulfills type of coordination 1) Type of coordination 2, Iq = 150 kA 1 NC (contactor)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail","Mounting Position":"vertical","PROFIsafe protocol":"No","Product Brand Name":"SIRIUS","Type Of Assignment":"2","Product Designation":"Reversing starter","Size Of Load Feeder":"S00","PROFINET IO protocol":"No","at 400 V rated value":"90 kW","at 480 V rated value":"0.4 A","at 600 V rated value":"0.4 A","Design Of The Product":"for standard rail or screw mounting","For Main Current Circuit":"spring-loaded terminals","Temperature Compensation":"-20 ... +60 °C","Of The Supplied Contactor":"3RT2015-2BB42","Of The Supplied Link Module":"3RA2911-2AA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","at AC-3 at 400 V rated value":"0.4 A","at AC-3e rated value maximum":"690 V","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"0.4 A","Design Of The Overload Release":"thermal (bimetallic)","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-0EA20","degree of protection NEMA rating":"other","For Auxiliary And Control Circuit":"spring-loaded terminals","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Without Load Current Share Typical":"4 W","holding power of magnet coil at DC":"4 W","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"2 W","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","protocol is supported AS-Interface protocol":"No","with high demand rate according to SN 31920":"73 %","reference code according to IEC 81346-2:2019":"Q","shock resistance according to IEC 60068-2-27":"6g / 11 ms","Type Of Voltage Of The Control Supply Voltage":"DC","at 400 V according to IEC 60947-4-1 rated value":"150 000 A","Mechanical Service Life (Operating Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"5.2 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.28 ... 0.4 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f22d221219025974fc23fae454c5e3c5.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=125619&mlfb=3RA2210-0EE15-2BB4"},"ai":{"faq":[{"question":"How can I get pricing and availability for 3RA2210-0EE15-2BB4?","answer":"Submit an RFQ with your BOM quantity."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2210-0EE15-2BB4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2210-0EE15-2BB4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}