{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2210-0EH15-2BB4","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2210-0EH15-2BB4","canonicalUrl":"https://aoctrl.com/siemens/3RA2210-0EH15-2BB4","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2210-0EH15-2BB4","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS reversing starter, Size S00, 0.4 A at 400 V AC-3, Class 10, spring-loaded terminals, for 60 mm busbar systems.","salesMarkdown":"## SIRIUS reversing starter, Size S00 — busbar-mounted motor reversing The Siemens 3RA2210-0EH15-2BB4 is a SIRIUS reversing starter in Size S00, designed to snap directly onto 60 mm busbar systems — no separate DIN-rail adapter needed for the main power feed. It ships as a factory-assembled unit containing the contactor 3RT2015-2BB42, the link module 3RA2911-2AA00, and the RS assembly kit 3RA2913-1DB2 — one order code covers the reversing pair and the mechanical interlock. The 90 kW rating at 400 V applies to the contactor's motor-switching capacity in this configuration. The thermal bimetallic overload release is set to Trip Class 10 — it protects standard squirrel-cage motors during start-up without nuisance tripping on normal acceleration. ## Mounting clearances and panel fit Dimensions are 155 mm deep, 90 mm wide, 260 mm high. The vertical mounting position is mandatory — the bimetallic trip curve assumes upright orientation for natural convection. Required clearances: 50 mm above, 32 mm in front, 10 mm below, 10 mm at each side, and 0 mm behind (the busbar mount takes the back plane). These gaps must be maintained for arc containment and cooling airflow. ## Environmental and compliance documentation Operating temperature range is -20 to +60 °C; storage and transport range is -50 to +80 °C. The -20 °C floor is common for unheated plant areas — the bimetallic element compensates across the full band. RoHS compliance date is 10 January 2009, covering the EU RoHS recast. The part carries no PROFIsafe or PROFINET IO protocol — it is a hard-wired reversing starter, not a fieldbus slice.","metaTitle":"Siemens 3RA2210-0EH15-2BB4 SIRIUS Reversing Starter","metaDescription":"Siemens SIRIUS reversing starter 3RA2210-0EH15-2BB4, Size S00, 0.4 A at 400 V AC-3, Class 10, snaps onto 60 mm busbars. Current production — quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Starters"],"specifications":{"Depth":"155 mm","Width":"90 mm","title":"3RA2210-0EH15-2BB4","Height":"260 mm","Upwards":"50 mm","Forwards":"32 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"10 mm","Rated Value":"24 ... 24 V","description":"Load feeder fuseless, Reversing duty 400 V AC, Size S00 0.28...0.40 A 24 V DC Spring-type terminal for 60 mm busbar systems (also fulfills type of coordination 1) Type of coordination 2, Iq = 150 kA 1 NC (contactor)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"for snapping onto 60 mm busbar systems","Mounting Position":"vertical","PROFIsafe protocol":"No","Product Brand Name":"SIRIUS","Type Of Assignment":"2","Product Designation":"Reversing starter","Size Of Load Feeder":"S00","PROFINET IO protocol":"No","at 400 V rated value":"90 kW","at 480 V rated value":"0.4 A","at 600 V rated value":"0.4 A","Design Of The Product":"for 60 mm busbars","For Main Current Circuit":"spring-loaded terminals","Temperature Compensation":"-20 ... +60 °C","Of The Supplied Contactor":"3RT2015-2BB42","Of The Supplied Link Module":"3RA2911-2AA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","at AC-3 at 400 V rated value":"0.4 A","at AC-3e rated value maximum":"690 V","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"0.4 A","Design Of The Overload Release":"thermal (bimetallic)","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","of the supplied RS assembly kit":"3RA2913-1DB2","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-0EA20","degree of protection NEMA rating":"other","For Auxiliary And Control Circuit":"spring-loaded terminals","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Without Load Current Share Typical":"4 W","holding power of magnet coil at DC":"4 W","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"2 W","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","protocol is supported AS-Interface protocol":"No","with high demand rate according to SN 31920":"73 %","reference code according to IEC 81346-2:2019":"Q","shock resistance according to IEC 60068-2-27":"6g / 11 ms","Type Of Voltage Of The Control Supply Voltage":"DC","at 400 V according to IEC 60947-4-1 rated value":"150 000 A","Mechanical Service Life (Operating Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"5.2 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.28 ... 0.4 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/72af2fad4dbb15c6dc6fd6dfed641bd2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=132222&mlfb=3RA2210-0EH15-2BB4"},"ai":{"faq":[{"question":"What compliance documentation does Siemens provide for this reversing starter?","answer":"RoHS compliance is documented with a substance prohibitance date of 10 January 2009, covering the EU RoHS recast. The unit is a hard-wired electromechanical starter — no fieldbus protocol certificates apply."},{"question":"What are the key ratings of the 3RA2210-0EH15-2BB4?","answer":"The thermal overload release is Trip Class 10. Operating frequency is 50…60 Hz."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2210-0EH15-2BB4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2210-0EH15-2BB4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}