{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2210-0FD15-2AK6","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2210-0FD15-2AK6","canonicalUrl":"https://aoctrl.com/siemens/3RA2210-0FD15-2AK6","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2210-0FD15-2AK6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2210-0FD15-2AK6 non-fused load feeder, reversing starter, size S00, CLASS 10 thermal bimetallic overload, 690 V rated, 50/60 Hz, snap-on 60 mm busbar.","salesMarkdown":"## Reversing starter in a single package The 3RA2210-0FD15-2AK6 is a SIRIUS non-fused load feeder configured as a reversing starter, size S00 — meaning forward and reverse contactors plus a thermal bimetallic overload relay are integrated into one unit that snaps onto a 60 mm busbar system. It ships with a 3RT2015-1AK62 contactor, a 3RA1921-1DA00 link module, and an 8US1251-5DS10 busbar adapter — the panel builder gets a pre-coordinated set, not a pile of loose components. ## Rated voltage ceiling and trip class The magnetic short-circuit trip handles fault clearing independently of the thermal element, so a locked-rotor or phase-to-phase fault is interrupted before the bimetallic element sees the full let-through energy. Rated frequency is 50/60 Hz — the same unit covers both line frequencies without derating, which simplifies stocking for multi-standard panels. ## Panel fit and mounting constraints Envelope is 200 mm high × 90 mm wide × 155.1 mm deep, with 20 mm clearance required above and 10 mm below — the forward and backward clearance is zero, so the unit sits flush against the mounting surface. Mounting position is vertical only; the fastening method is snap-on for 60 mm busbar systems, not DIN rail — confirm the busbar pitch matches before committing the panel layout. Degree of pollution 3 means the unit is rated for conductive pollution environments typical of industrial control panels — no additional conformal coating required for normal factory floor conditions. ## Operating environment and wiring Operates from -20 to +60 °C ambient, with storage and transport range of -50 to +80 °C — suitable for unheated warehouses and container shipping without special conditioning.","metaTitle":"Siemens 3RA2210-0FD15-2AK6 SIRIUS reversing starter, S00","metaDescription":"Siemens 3RA2210-0FD15-2AK6 SIRIUS non-fused load feeder, reversing starter, size S00, CLASS 10 thermal overload, 690 V rated value.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Starters"],"specifications":{"Depth":"155.1 mm","Width":"90 mm","title":"3RA2210-0FD15-2AK6","Height":"200 mm","Upwards":"20 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"690 V","description":"FUSELESS LOAD FEEDER REVERSING OPERATION, 400 V AC, SZ 00 0.35 TO 0.50 A 3 KW, 110/120 V AC 50/60 HZ SCREW TERMINAL FOR 60 MM BUSBAR SYSTEMS TYPE OF COORDINATION 2, IQ = 150 KA (ALSO FULFILLS TYPE OF COORDINATION 1) 1NC (CONTACTOR)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"for snapping onto 60 mm busbar systems","Mounting Position":"vertical","Product Brand Name":"SIRIUS","Type Of Assignment":"2","Degree Of Pollution":"3","Product Designation":"non-fused load feeders 3RA2","Size Of Load Feeder":"S00","at 400 V rated value":"120 W","at 50 Hz rated value":"110 V","at 500 V rated value":"180 W","at 60 Hz rated value":"120 V","at 690 V rated value":"250 W","Design Of The Product":"reversing starter","Of The Supplied Contactor":"3RT2015-1AK62","For Main Contacts Stranded":"0.5 ... 4 mm², 2x (0.75 ... 2.5 mm²)","Of The Supplied Link Module":"3RA1921-1DA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","Substance Prohibitance (Date)":"10/01/2009","Design Of The Overload Release":"thermal (bimetallic)","Of The Supplied Busbar Adapter":"8US1251-5DS10","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","at AWG cables for main contacts":"2x (20 ... 16), only for contactor 2x (18 ... 14), 2x 12","of the supplied RS assembly kit":"8US1250-5AS10","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-0FA10","Product Extension Auxiliary Switch":"Yes","Surge Voltage Resistance Rated Value":"6 kV","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","apparent holding power of magnet coil at AC":"4.2 VA","shock resistance according to IEC 60068-2-27":"6g / 11 ms","at 400 V according to IEC 60947-4-1 rated value":"153 000 A","at 500 V according to IEC 60947-4-1 rated value":"100 000 A","at 690 V according to IEC 60947-4-1 rated value":"100 000 A","operational current at AC-3 at 400 V rated value":"0.4 A","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","Mechanical Service Life (Switching Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"6.5 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.35 ... 0.5 A","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e71bbf8abe9f73bbbbf8484e6f405e65.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=132288&mlfb=3RA2210-0FD15-2AK6"},"ai":{"faq":[{"question":"What is the lead time for 3RA2210-0FD15-2AK6?","answer":"Lead time is confirmed at the time of RFQ against your specific BOM quantity. As a current-production Siemens SIRIUS part, it is available through authorized distribution with typical industrial-automation lead times."},{"question":"What compliance documentation does Siemens provide for 3RA2210-0FD15-2AK6?","answer":"Standard Siemens documentation includes CE declaration of conformity and the product drawing with dimensions and mounting details."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2210-0FD15-2AK6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2210-0FD15-2AK6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}