{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2210-0JH15-2BB4","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2210-0JH15-2BB4","canonicalUrl":"https://aoctrl.com/siemens/3RA2210-0JH15-2BB4","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2210-0JH15-2BB4","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2210-0JH15-2BB4 reversing starter, size S00, 1 A at 400 V AC-3, Class 10 thermal overload, spring-loaded terminals, for 60 mm busbar systems.","salesMarkdown":"## Active production — what that means for your BOM line The 3RA2210-0JH15-2BB4: For a motor drawing 1 A FLA at 400 V, this starter covers it cleanly. ## Mounting and integration — busbar snap-on, no DIN rail This reversing starter is designed specifically for snapping onto 60 mm busbar systems — not a standard DIN rail. The mounting position is vertical, and the clearance requirements are: 50 mm upwards, 32 mm forwards, 0 mm backwards, 10 mm downwards, and 10 mm at the side. If your panel layout uses 60 mm busbars, this snaps on without extra brackets. The main circuit termination uses spring-loaded terminals — no screw torque to verify, just push the stripped wire in. That saves time on a panel build and eliminates a common QC check point. ## Thermal overload and trip class — Class 10, bimetallic The overload release is thermal bimetallic, Class 10. If your load has a long ramp (high-inertia fan or conveyor), Class 10 might nuisance-trip; for most pump and compressor starts it's the right fit. The rated control supply voltage is 24 V DC — confirm your control transformer or power supply matches that before wiring. The operating temperature range is -20 to +60 °C, with storage and transport range from -50 to +80 °C.","metaTitle":"Siemens 3RA2210-0JH15-2BB4 Reversing Starter, S00","metaDescription":"Siemens SIRIUS reversing starter, size S00, 1 A AC-3 at 400 V, Class 10 thermal overload. Active production — sourced to order. Snap-on for 60 mm busbars.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Starters"],"specifications":{"Depth":"155 mm","Width":"90 mm","title":"3RA2210-0JH15-2BB4","Height":"260 mm","Upwards":"50 mm","Forwards":"32 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"10 mm","Rated Value":"24 ... 24 V","description":"Load feeder fuseless, Reversing duty 400 V AC, Size S00 0.70...1.00 A 24 V DC Spring-type terminal for 60 mm busbar systems (also fulfills type of coordination 1) Type of coordination 2, Iq = 150 kA 1 NC (contactor)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"for snapping onto 60 mm busbar systems","Mounting Position":"vertical","PROFIsafe protocol":"No","Product Brand Name":"SIRIUS","Type Of Assignment":"2","Product Designation":"Reversing starter","Size Of Load Feeder":"S00","PROFINET IO protocol":"No","at 400 V rated value":"250 kW","at 480 V rated value":"1 A","at 600 V rated value":"1 A","Design Of The Product":"for 60 mm busbars","For Main Current Circuit":"spring-loaded terminals","Temperature Compensation":"-20 ... +60 °C","at 460/480 V rated value":"0.5 hp","at 575/600 V rated value":"0.5 hp","Of The Supplied Contactor":"3RT2015-2BB42","Of The Supplied Link Module":"3RA2911-2AA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","at AC-3 at 400 V rated value":"1 A","at AC-3e rated value maximum":"690 V","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"1 A","Design Of The Overload Release":"thermal (bimetallic)","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","of the supplied RS assembly kit":"3RA2913-1DB2","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-0JA20","degree of protection NEMA rating":"other","For Auxiliary And Control Circuit":"spring-loaded terminals","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Without Load Current Share Typical":"4 W","holding power of magnet coil at DC":"4 W","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"2.6 W","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","protocol is supported AS-Interface protocol":"No","with high demand rate according to SN 31920":"73 %","reference code according to IEC 81346-2:2019":"Q","shock resistance according to IEC 60068-2-27":"6g / 11 ms","Type Of Voltage Of The Control Supply Voltage":"DC","at 400 V according to IEC 60947-4-1 rated value":"150 000 A","Mechanical Service Life (Operating Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"13 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.7 ... 1 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/82dc80337b870b2566ea9fd8586cabc5.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=457004&mlfb=3RA2210-0JH15-2BB4"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3RA2210-0JH15-2BB4?","answer":"Submit an RFQ through this listing — availability is verified from authorized Siemens distribution at the time of request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2210-0JH15-2BB4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2210-0JH15-2BB4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}