{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2210-0KD15-2AP0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2210-0KD15-2AP0","canonicalUrl":"https://aoctrl.com/siemens/3RA2210-0KD15-2AP0","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2210-0KD15-2AP0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS reversing starter, size S00, 1.25 A AC-3 at 400 V, Class 10, screw terminals, for 60 mm busbar snap-on mounting, supplied with 3RT2015-1AP02 contactor and 3RA1921-1DA00 link module.","salesMarkdown":"## What this reversing starter delivers for a motor branch The 3RA2210-0KD15-2AP0: It ships with the 3RT2015-1AP02 contactor and the 3RA1921-1DA00 link module already integrated — one order code covers the reversing pair and the mechanical interlock, so you are not sourcing three separate line items. ## Busbar mounting and panel fit Designed for snapping onto 60 mm busbar systems — the fastening method is a clip-on, not DIN rail, so the panel layout needs busbar support, not a top-hat rail. Dimensions are 155 mm deep, 90 mm wide, and 204 mm high — the width is tight for a reversing starter, so it fits in a shallow enclosure if the busbar is pre-routed. Mounting position is vertical only; clearance requirements are 50 mm upwards, 32 mm forwards, 10 mm downwards, and 10 mm at the side — the backwards clearance is zero, meaning the busbar must be the rear boundary. No stock-holding claim — the spread is in the supplier reliability, not the shelf count. The supplied contactor (3RT2015-1AP02) and link module (3RA1921-1DA00) are standard SIRIUS catalog items, so replacement spares are straightforward if the integrated unit is ever damaged.","metaTitle":"Siemens 3RA2210-0KD15-2AP0 SIRIUS Reversing Starter, S00","metaDescription":"Siemens 3RA2210-0KD15-2AP0 SIRIUS reversing starter, size S00, 1.25 A at 400 V AC-3, Class 10, for 60 mm busbar systems. Active production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Starters"],"specifications":{"Depth":"155 mm","Width":"90 mm","title":"3RA2210-0KD15-2AP0","Height":"204 mm","Upwards":"50 mm","Forwards":"32 mm","at 50 Hz":"0.25","at 60 Hz":"0.25","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"10 mm","Rated Value":"690 V","description":"Load feeder fuseless, Reversing duty 400 V AC, Size S00 0.90...1.25 A 230 V AC screw terminal for 60 mm busbar systems (also fulfills type of coordination 1) Type of coordination 2, Iq = 150 kA 1 NC (contactor)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"for snapping onto 60 mm busbar systems","Mounting Position":"vertical","PROFIsafe protocol":"No","Product Brand Name":"SIRIUS","Type Of Assignment":"2","Product Designation":"Reversing starter","Size Of Load Feeder":"S00","PROFINET IO protocol":"No","at 400 V rated value":"370 kW","at 480 V rated value":"1.25 A","at 50 Hz rated value":"230 ... 230 V","at 60 Hz rated value":"230 ... 230 V","at 600 V rated value":"1.25 A","Design Of The Product":"for 60 mm busbars","For Main Current Circuit":"screw-type terminals","Temperature Compensation":"-20 ... +60 °C","at 460/480 V rated value":"0.75 hp","at 575/600 V rated value":"0.75 hp","Of The Supplied Contactor":"3RT2015-1AP02","Of The Supplied Link Module":"3RA1921-1DA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","at AC-3 at 400 V rated value":"1.25 A","at AC-3e rated value maximum":"690 V","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"1.25 A","Design Of The Overload Release":"thermal (bimetallic)","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","of the supplied RS assembly kit":"3RA2913-1DB1","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-0KA10","degree of protection NEMA rating":"other","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Without Load Current Share Typical":"4.2 W","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"2.6 W","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","apparent holding power of magnet coil at AC":"4.2 VA","protocol is supported AS-Interface protocol":"No","with high demand rate according to SN 31920":"73 %","reference code according to IEC 81346-2:2019":"Q","shock resistance according to IEC 60068-2-27":"6g / 11 ms","Type Of Voltage Of The Control Supply Voltage":"AC","at 400 V according to IEC 60947-4-1 rated value":"150 000 A","Inductive Power Factor With The Holding Power Of The Coil":"0.25","Mechanical Service Life (Operating Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"16 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.9 ... 1.25 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e32acf0758762d1321a1968a1e228453.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=415129&mlfb=3RA2210-0KD15-2AP0"},"ai":{"faq":[{"question":"Will this drop into a panel designed for a different reversing starter without rewiring?","answer":"It mounts on 60 mm busbars, not DIN rail, and the clearance envelope is specific (50 mm up, 32 mm forward, 10 mm down, 10 mm side, zero backward). If the existing panel was laid out for a DIN-rail-mounted starter, the busbar interface and footprint are different — expect to rework the mounting and busbar connections."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2210-0KD15-2AP0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2210-0KD15-2AP0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}