{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2210-1AD15-2AP6","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2210-1AD15-2AP6","canonicalUrl":"https://aoctrl.com/siemens/3RA2210-1AD15-2AP6","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2210-1AD15-2AP6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2210-1AD15-2AP6 non-fused reversing motor starter, Size S00, 550 W at 400 V AC-3, Class 10 thermal bimetallic overload, 690 V rated insulation, snap-on 60 mm busbar mounting.","salesMarkdown":"## Reversing starter, Size S00 — 550 W at 400 V The 3RA2210-1AD15-2AP6: That power rating covers fractional-horsepower motors typical on small conveyors, pumps, and valve actuators where forward/reverse control is needed. The reversing configuration means the starter integrates two contactors mechanically interlocked — one for forward, one for reverse — plus the thermal overload relay, all in a single 90 mm wide package. This saves panel space versus wiring two separate contactors with an external interlock. The control voltage range is 187–242 V at 50 Hz and 192–264 V at 60 Hz, covering standard 230 V control circuits. ## Class 10 thermal overload — what it means for motor protection The overload release is thermal bimetallic, Trip Class 10. The thermal bimetallic design responds to the motor's actual heating curve, not just instantaneous current. This gives better protection for intermittent-duty cycles than a magnetic-only device, because the bimetal integrates the I²t heating over time. Operating temperature range is -20 to +60 °C, with storage from -50 to +80 °C. The thermal trip characteristic shifts with ambient temperature — in a hot panel near the upper limit, the effective trip current derates slightly. Plan for this if the starter sits next to heat-generating drives or transformers. ## Snap-on busbar mounting and panel integration This starter fastens by snapping onto 60 mm busbar systems — the standard Siemens SIRIUS busbar adapter 8US1251-5DS10 is supplied with the unit. No DIN rail required if you're using the busbar distribution system; the adapter clips the starter directly to the busbar and makes the power connection. Mounting position is vertical only. Dimensions are 200 mm height, 90 mm width, 155.1 mm depth. The clearance requirements are: 20 mm upwards, 10 mm downwards, 9 mm at the side, and 0 mm forwards or backwards — so it can be stacked tight against the back panel or enclosure wall. The supplied contactor is 3RT2015-1AP62 and the link module is 3RA1921-1DA00 — these are pre-assembled and wired internally. ## Active production — sourcing for project milestones RoHS compliance date is 03/01/2017 — the starter meets the EU RoHS directive for substances of concern.","metaTitle":"Siemens 3RA2210-1AD15-2AP6 SIRIUS Reversing Motor Starter","metaDescription":"Siemens 3RA2210-1AD15-2AP6 SIRIUS non-fused reversing motor starter, Size S00, 550 W at 400 V, Class 10 thermal overload.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Starters"],"specifications":{"Depth":"155.1 mm","Width":"90 mm","title":"3RA2210-1AD15-2AP6","Height":"200 mm","Upwards":"20 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"690 V","description":"FUSELESS MOTOR STARTER REVERSING OPERATION 600V AC SZ S00 1.1-1.6A 220/240V AC 50/60HZ SCREW CONNECTION FOR SNAPPING ONTO 60 MM BUSBAR SYSTEMS TYPE OF COORDINATION 2 IQ = 150 KA ALSO FULFILLS TYPE OF COORDINATION 1 1NC (PER CONTACTOR)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-55 ... +80 °C","Fastening Method":"for snapping onto 60 mm busbar systems","Mounting Position":"vertical","Product Brand Name":"SIRIUS","Type Of Assignment":"2","Degree Of Pollution":"3","Product Designation":"non-fused motor starter 3RA2","Size Of Load Feeder":"S00","at 230 V rated value":"0.1 hp","at 400 V rated value":"550 W","at 480 V rated value":"1.6 A","at 50 Hz rated value":"187 ... 242 V","at 500 V rated value":"550 W","at 60 Hz rated value":"192 ... 264 V","at 600 V rated value":"1.3 A","at 690 V rated value":"1 100 W","Design Of The Product":"reversing starter","at 460/480 V rated value":"0.75 hp","at 575/600 V rated value":"0.75 hp","Of The Supplied Contactor":"3RT2015-1AP62","For Main Contacts Stranded":"0.5 ... 4 mm², 2x (0.75 ... 2.5 mm²)","Of The Supplied Link Module":"3RA1921-1DA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","Substance Prohibitance (Date)":"03/01/2017","Design Of The Overload Release":"thermal (bimetallic)","Of The Supplied Busbar Adapter":"8US1251-5DS10","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","at AWG cables for main contacts":"2x (20 ... 16), only for contactor 2x (18 ... 14), 2x 12","of the supplied RS assembly kit":"3RA2913-1DB1","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-1AA10","Product Extension Auxiliary Switch":"Yes","Surge Voltage Resistance Rated Value":"6 kV","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","apparent holding power of magnet coil at AC":"4.8 VA","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"0","shock resistance according to IEC 60068-2-27":"6g / 11 ms","at 400 V according to IEC 60947-4-1 rated value":"153 000 A","at 500 V according to IEC 60947-4-1 rated value":"100 000 A","at 690 V according to IEC 60947-4-1 rated value":"100 000 A","operational current at AC-3 at 400 V rated value":"1.5 A","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","Inductive Power Factor With The Holding Power Of The Coil":"0.25","Mechanical Service Life (Switching Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"20.8 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"1.1 ... 1.6 A","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e394e0ed6cc4b7fd61cac5d195a7b529.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=175935&mlfb=3RA2210-1AD15-2AP6"},"ai":{"faq":[{"question":"What is the closest functional second-source for 3RA2210-1AD15-2AP6?","answer":"The 6ES7517-3FP00-0AB0 and 6ES7214-1BG40-0XB0 are Siemens PLC modules, not motor starters — they are not functional replacements. The 3RA2210-1AD15-2AP6 is a dedicated reversing motor starter; a substitute would need to match the Size S00 footprint, Class 10 thermal overload, and 550 W at 400 V rating."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2210-1AD15-2AP6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2210-1AD15-2AP6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}