{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2210-1AE15-2BB4","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2210-1AE15-2BB4","canonicalUrl":"https://aoctrl.com/siemens/3RA2210-1AE15-2BB4","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2210-1AE15-2BB4","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2210-1AE15-2BB4 reversing starter, size S00, 1.6 A at 400 V AC-3, Class 10, spring-loaded terminals, screw and snap-on mounting on 35 mm DIN rail.","salesMarkdown":"## 1.6 A AC-3 at 400 V — what that means on the line The 3RA2210-1AE15-2BB4: The 1.6 A at 400 V works out to roughly 0.75 kW (1 hp) motor, consistent with the 1 hp rating at 460/480 V and 575/600 V. For a 1.6 A motor, the thermal memory tracks both running and cool-down periods, so a hot restart won't catch you off guard. ## Panel fit and mounting — DIN rail or screw, your call Mounts either by snapping onto 35 mm DIN rail or with screws — the same part covers both, so you don't need a separate adapter for a screw-down panel. The 90 mm width, 204 mm height, and 97 mm depth fit a standard S00 footprint; plan for 50 mm clearance above, 32 mm in front, and 10 mm on the sides and below for airflow and wiring access. The supplied contactor is a 3RT2015-2BB42 and the link module is a 3RA2911-2AA00, so the reversing interlock is built into the assembly, not something you wire up from scratch. ## Active production — no lifecycle surprises That means you can spec it into a new BOM without worrying about a last-time-buy window closing mid-project. The 24 V DC coil voltage is common across the SIRIUS family, so panel spares can be shared with other S00 contactors in the same cabinet. RoHS compliance date of October 1, 2009 is on file — the part meets the EU substance restrictions.","metaTitle":"Siemens 3RA2210-1AE15-2BB4 Reversing Starter, S00","metaDescription":"Siemens SIRIUS 3RA2210-1AE15-2BB4 reversing starter, size S00, 1.6 A at 400 V AC-3, Class 10 trip. Active production. Spring-loaded terminals. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Starters"],"specifications":{"Depth":"97 mm","Width":"90 mm","title":"3RA2210-1AE15-2BB4","Height":"204 mm","Upwards":"50 mm","Forwards":"32 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"10 mm","Rated Value":"24 ... 24 V","description":"Load feeder fuseless, Reversing duty 400 V AC, Size S00 1.10...1.60 A 24 V DC Spring-type terminal for installation on standard mounting rail (also fulfills type of coordination 1) Type of coordination 2, Iq = 150 kA 1 NC (contactor)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail","Mounting Position":"vertical","PROFIsafe protocol":"No","Product Brand Name":"SIRIUS","Type Of Assignment":"2","Product Designation":"Reversing starter","Size Of Load Feeder":"S00","PROFINET IO protocol":"No","at 230 V rated value":"0.1 hp","at 400 V rated value":"550 kW","at 480 V rated value":"1.6 A","at 600 V rated value":"1.6 A","Design Of The Product":"for standard rail or screw mounting","For Main Current Circuit":"spring-loaded terminals","Temperature Compensation":"-20 ... +60 °C","at 220/230 V rated value":"0.5 hp","at 460/480 V rated value":"1 hp","at 575/600 V rated value":"1 hp","Of The Supplied Contactor":"3RT2015-2BB42","Of The Supplied Link Module":"3RA2911-2AA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","at AC-3 at 400 V rated value":"1.6 A","at AC-3e rated value maximum":"690 V","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"1.6 A","Design Of The Overload Release":"thermal (bimetallic)","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-1AA20","degree of protection NEMA rating":"other","For Auxiliary And Control Circuit":"spring-loaded terminals","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Without Load Current Share Typical":"4 W","holding power of magnet coil at DC":"4 W","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"2.6 W","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","protocol is supported AS-Interface protocol":"No","with high demand rate according to SN 31920":"73 %","reference code according to IEC 81346-2:2019":"Q","shock resistance according to IEC 60068-2-27":"6g / 11 ms","Type Of Voltage Of The Control Supply Voltage":"DC","at 400 V according to IEC 60947-4-1 rated value":"150 000 A","Mechanical Service Life (Operating Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"21 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"1.1 ... 1.6 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b58987d88fc444e44c13c9f3dd55e470.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=151101&mlfb=3RA2210-1AE15-2BB4"},"ai":{"faq":[{"question":"What is the 1.6 A rating at 400 V — is that the full-load motor current or the contact rating?","answer":"The maximum operating voltage is 690 V AC-3 and AC-3e. For a 1.6 A motor at 400 V, you're looking at roughly 0.75 kW (1 hp)."},{"question":"What clearance do I need around this reversing starter in the panel?","answer":"The mounting position is vertical. Allow 50 mm upwards, 32 mm forwards, 10 mm downwards, and 10 mm at the sides for airflow and wiring access. Backwards clearance is 0 mm — it can sit flush against the back panel or mounting plate."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2210-1AE15-2BB4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2210-1AE15-2BB4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}