{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2210-1EE15-2BB4","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2210-1EE15-2BB4","canonicalUrl":"https://aoctrl.com/siemens/3RA2210-1EE15-2BB4","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2210-1EE15-2BB4","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2210-1EE15-2BB4 reversing starter, size S00, 4 A at 400 V AC-3, Class 10, 24 V DC coil, screw and snap-on 35 mm DIN rail mounting.","salesMarkdown":"## Reversing starter for compact motor control The Siemens 3RA2210-1EE15-2BB4 is a SIRIUS reversing starter in size S00, combining two contactors and a mechanical interlock in a single assembly for forward/reverse control of three-phase motors up to 4 A at 400 V AC-3. Rated for AC-3 switching duty up to 690 V maximum, this unit is built for the standard reversing motor control function — two contactors cross-wired with a mechanical interlock that prevents both coils from pulling in simultaneously. The 24 V DC coil (24... 24 V rated value) keeps the control circuit in the low-voltage safety range, which simplifies compliance with machinery directive isolation requirements. ## Panel fit and mounting constraints Mounts on 35 mm DIN rail via the screw-and-snap-on method, or can be screw-mounted directly to a backplate — vertical orientation only, per the mounting position spec. Side clearance is 10 mm on each side; no backward clearance is required, so the unit can sit flush against a rear panel or busbar support. ## What the AC-3 rating means for motor sizing At 400 V AC-3 (the standard motor-switching duty category), this reversing starter is rated 4 A — this is the current it can make and break motor loads under full-load running conditions, not the locked-rotor inrush that the contactor must handle momentarily. ## Included components and wiring terminals This reversing starter ships with the 3RT2015-2BB42 contactor and the 3RA2911-2AA00 link module pre-assembled — the mechanical interlock and power bus connections are factory-integrated, so field wiring is reduced to the control and motor leads. The main current circuit uses spring-loaded terminals (cage-clamp style), which hold solid or ferruled stranded wire without periodic re-torquing — relevant for a maintenance interval on a production line where vibration is present. Operating temperature range is -20 to +60 °C with the same range for temperature compensation; storage and transport limits extend to -50 to +80 °C. Submit an RFQ for volume pricing and lead time.","metaTitle":"Siemens 3RA2210-1EE15-2BB4 Reversing Starter, S00, 4 A AC-3","metaDescription":"Siemens SIRIUS 3RA2210-1EE15-2BB4 reversing starter, size S00, 4 A at 400 V AC-3, Class 10, 24 V coil. Active production, quoted to order. Request a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Starters"],"specifications":{"Depth":"97 mm","Width":"90 mm","title":"3RA2210-1EE15-2BB4","Height":"204 mm","Upwards":"50 mm","Forwards":"32 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"10 mm","Rated Value":"24 ... 24 V","description":"Load feeder fuseless, Reversing duty 400 V AC, Size S00 2.80...4.00 A 24 V DC Spring-type terminal for installation on standard mounting rail (also fulfills type of coordination 1) Type of coordination 2, Iq = 150 kA 1 NC (contactor)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail","Mounting Position":"vertical","PROFIsafe protocol":"No","Product Brand Name":"SIRIUS","Type Of Assignment":"2","Product Designation":"Reversing starter","Size Of Load Feeder":"S00","PROFINET IO protocol":"No","at 230 V rated value":"0.5 hp","at 400 V rated value":"1 500 kW","at 480 V rated value":"4 A","at 600 V rated value":"4 A","Design Of The Product":"for standard rail or screw mounting","For Main Current Circuit":"spring-loaded terminals","Temperature Compensation":"-20 ... +60 °C","at 110/120 V rated value":"0.16 hp","at 200/208 V rated value":"1 hp","at 220/230 V rated value":"1 hp","at 460/480 V rated value":"3 hp","at 575/600 V rated value":"3 hp","Of The Supplied Contactor":"3RT2015-2BB42","Of The Supplied Link Module":"3RA2911-2AA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","at AC-3 at 400 V rated value":"4 A","at AC-3e rated value maximum":"690 V","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"4 A","Design Of The Overload Release":"thermal (bimetallic)","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-1EA20","degree of protection NEMA rating":"other","For Auxiliary And Control Circuit":"spring-loaded terminals","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Without Load Current Share Typical":"4 W","holding power of magnet coil at DC":"4 W","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"2.6 W","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","protocol is supported AS-Interface protocol":"No","with high demand rate according to SN 31920":"73 %","reference code according to IEC 81346-2:2019":"Q","shock resistance according to IEC 60068-2-27":"6g / 11 ms","Type Of Voltage Of The Control Supply Voltage":"DC","at 400 V according to IEC 60947-4-1 rated value":"150 000 A","Mechanical Service Life (Operating Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"52 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"2.8 ... 4 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/0bfd372c8f547a1e9c650a24d6329168.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=80842&mlfb=3RA2210-1EE15-2BB4"},"ai":{"faq":[{"question":"What is 3RA2210-1EE15-2BB4's depth and width for panel layout?","answer":"The depth is 97 mm and the width is 90 mm. Height is 204 mm. Allow 50 mm upward clearance for wiring access and 32 mm forward clearance for the spring-loaded terminals. Side clearance is 10 mm each side; no backward clearance is required."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2210-1EE15-2BB4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2210-1EE15-2BB4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}