{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2210-1FH15-2AP0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2210-1FH15-2AP0","canonicalUrl":"https://aoctrl.com/siemens/3RA2210-1FH15-2AP0","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2210-1FH15-2AP0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2210-1FH15-2AP0 reversing starter, Size S00, 5 A at 600 V, spring-loaded terminals, 60 mm busbar snap-on, Trip Class 10, 690 V rated insulation.","salesMarkdown":"## What this reversing starter fits — and what it doesn't The 3RA2210-1FH15-2AP0 is a SIRIUS reversing starter in Size S00, designed to snap onto 60 mm busbar systems — not a DIN rail mount, not a panel screw-down. If your panel is built around standard 35 mm DIN rail, this part needs an adapter or a different frame. It ships as a complete assembly: the supplied contactor is a 3RT2015-2AP02, and the link module is 3RA2911-2AA00. That means the reversing interlock and mechanical linkage are pre-configured — no separate wiring of a mechanical interlock between two contactors. The main circuit terminals are spring-loaded, not screw-clamp. That's fine for solid and ferruled stranded wire up to the rated cross-section, but if your shop standard is ring-tongue crimp lugs, you'll need to adapt or swap the terminal type. ## Motor ratings — the numbers that decide the BOM line For 230 V systems, it's 1.5 hp at 220/230 V or 0.5 hp at 230 V rated value — the lower horsepower at 230 V reflects the current-limited design of the S00 frame. That's standard for general-purpose motor starting — not for high-inertia loads that need a Class 20 or 30 curve. The operating temperature range is -20 to +60 °C, and the storage range is -50 to +80 °C — typical for a panel-mounted device in a conditioned enclosure. ## Mounting clearances — where it sits in the enclosure Physical dimensions are 155 mm deep, 90 mm wide, and 260 mm tall. Mounting is vertical only, and the clearance requirements are: 50 mm upwards, 32 mm forwards, 10 mm downwards, 10 mm at the side, and 0 mm backwards (it sits flush against the busbar). That 50 mm upward gap is the one that catches people — if you stack a busbar-fed starter below another device, you need that clearance for heat dissipation and wiring access.","metaTitle":"Siemens 3RA2210-1FH15-2AP0 SIRIUS Reversing Starter","metaDescription":"Siemens 3RA2210-1FH15-2AP0 SIRIUS reversing starter, Size S00, 5 A at 600 V, spring-loaded terminals, snaps onto 60 mm busbars.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Starters"],"specifications":{"Depth":"155 mm","Width":"90 mm","title":"3RA2210-1FH15-2AP0","Height":"260 mm","Upwards":"50 mm","Forwards":"32 mm","at 50 Hz":"0.25","at 60 Hz":"0.25","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"10 mm","Rated Value":"690 V","description":"Load feeder fuseless, Reversing duty 400 V AC, Size S00 3.50...5.00 A 230 V AC Spring-type terminal for 60 mm busbar systems Type of coordination 1, Iq = 150 kA 1 NC (contactor)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"for snapping onto 60 mm busbar systems","Mounting Position":"vertical","PROFIsafe protocol":"No","Product Brand Name":"SIRIUS","Type Of Assignment":"1","Product Designation":"Reversing starter","Size Of Load Feeder":"S00","PROFINET IO protocol":"No","at 230 V rated value":"0.5 hp","at 400 V rated value":"1 500 kW","at 480 V rated value":"4.8 A","at 50 Hz rated value":"230 ... 230 V","at 60 Hz rated value":"230 ... 230 V","at 600 V rated value":"5 A","Design Of The Product":"for 60 mm busbars","For Main Current Circuit":"spring-loaded terminals","Temperature Compensation":"-20 ... +60 °C","at 110/120 V rated value":"0.25 hp","at 200/208 V rated value":"1.5 hp","at 220/230 V rated value":"1.5 hp","at 460/480 V rated value":"3 hp","at 575/600 V rated value":"5 hp","Of The Supplied Contactor":"3RT2015-2AP02","Of The Supplied Link Module":"3RA2911-2AA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","at AC-3 at 400 V rated value":"5 A","at AC-3e rated value maximum":"690 V","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"5 A","Design Of The Overload Release":"thermal (bimetallic)","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","of the supplied RS assembly kit":"3RA2913-1DB2","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-1FA20","degree of protection NEMA rating":"other","For Auxiliary And Control Circuit":"spring-loaded terminals","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Without Load Current Share Typical":"4.2 W","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"2.6 W","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","apparent holding power of magnet coil at AC":"4.2 VA","protocol is supported AS-Interface protocol":"No","with high demand rate according to SN 31920":"73 %","reference code according to IEC 81346-2:2019":"Q","shock resistance according to IEC 60068-2-27":"6g / 11 ms","Type Of Voltage Of The Control Supply Voltage":"AC","at 400 V according to IEC 60947-4-1 rated value":"150 000 A","Inductive Power Factor With The Holding Power Of The Coil":"0.25","Mechanical Service Life (Operating Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"65 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"3.5 ... 5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/251a3c07b7aeab94a43519a2f9e6512b.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=448943&mlfb=3RA2210-1FH15-2AP0"},"ai":{"faq":[{"question":"Will 3RA2210-1FH15-2AP0 drop into a panel specified around 6ES7517-3FP00-0AB0?","answer":"No. The 6ES7517-3FP00-0AB0 is a Siemens S7-1500 CPU module, not a motor starter. The 3RA2210-1FH15-2AP0 is a reversing starter that snaps onto 60 mm busbars — entirely different form factor, wiring, and function. Rewiring and a panel layout change are required."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2210-1FH15-2AP0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2210-1FH15-2AP0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}