{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2210-1HH15-2AP0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2210-1HH15-2AP0","canonicalUrl":"https://aoctrl.com/siemens/3RA2210-1HH15-2AP0","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2210-1HH15-2AP0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS reversing starter, 3RA2210-1HH15-2AP0, size S00, CLASS 10, 0.25 kW at 230 V 50/60 Hz, spring-loaded terminals, for 60 mm busbar systems.","salesMarkdown":"## What this reversing starter is The 3RA2210-1HH15-2AP0 is a Siemens SIRIUS reversing starter, size S00 — a factory-assembled combination of a contactor pair and overload relay in one housing, wired to reverse a three-phase motor by swapping two phases. It ships with the 3RT2015-2AP02 contactor and the 3RA2911-2AA00 link module already integrated, so it saves panel wiring time versus building a reversing starter from discrete components. Rated for motor loads up to 0.25 kW at 230 V (50/60 Hz), with horsepower ratings climbing to 5 hp at 575/600 V — the actual load limit depends on the supply voltage and the motor full-load current. ## Mounting and panel fit Designed for snapping onto 60 mm busbar systems — the fastening method is a spring clip that engages the busbar rail, no tools needed for installation. Mounting position is vertical only, with 50 mm clearance required above, 32 mm in front, 10 mm at the sides, and 10 mm below — no clearance needed behind the unit since it mounts on the busbar face. Dimensions are 155 mm deep, 90 mm wide, 260 mm tall — the width is narrow enough to fit in a standard 600 mm-wide enclosure with room for additional feeders alongside. ## Termination and wiring Main current circuit uses spring-loaded terminals — push-in termination for solid or ferruled stranded conductors, no screwdriver needed for the power connections. Operating temperature range is -20 to +60 °C, with storage and transport limits from -50 to +80 °C — suitable for unheated warehouses and truck transport in temperate climates.","metaTitle":"Siemens 3RA2210-1HH15-2AP0 SIRIUS Reversing Starter","metaDescription":"Siemens 3RA2210-1HH15-2AP0 SIRIUS reversing starter, size S00, CLASS 10 trip, 0.25 kW at 50/60 Hz, spring-loaded terminals, snaps onto 60 mm busbars.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Starters"],"specifications":{"Depth":"155 mm","Width":"90 mm","title":"3RA2210-1HH15-2AP0","Height":"260 mm","Upwards":"50 mm","Forwards":"32 mm","at 50 Hz":"0.25","at 60 Hz":"0.25","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"10 mm","Rated Value":"690 V","description":"Load feeder fuseless, Reversing duty 400 V AC, Size S00 5.50...8.00 A 230 V AC Spring-type terminal for 60 mm busbar systems Type of coordination 1, Iq = 150 kA 1 NC (contactor)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"for snapping onto 60 mm busbar systems","Mounting Position":"vertical","PROFIsafe protocol":"No","Product Brand Name":"SIRIUS","Type Of Assignment":"1","Product Designation":"Reversing starter","Size Of Load Feeder":"S00","PROFINET IO protocol":"No","at 230 V rated value":"0.75 hp","at 400 V rated value":"3 000 kW","at 480 V rated value":"4.8 A","at 50 Hz rated value":"230 ... 230 V","at 60 Hz rated value":"230 ... 230 V","at 600 V rated value":"6.1 A","Design Of The Product":"for 60 mm busbars","For Main Current Circuit":"spring-loaded terminals","Temperature Compensation":"-20 ... +60 °C","at 110/120 V rated value":"0.25 hp","at 200/208 V rated value":"1.5 hp","at 220/230 V rated value":"2 hp","at 460/480 V rated value":"3 hp","at 575/600 V rated value":"5 hp","Of The Supplied Contactor":"3RT2015-2AP02","Of The Supplied Link Module":"3RA2911-2AA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","at AC-3 at 400 V rated value":"7 A","at AC-3e rated value maximum":"690 V","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"7 A","Design Of The Overload Release":"thermal (bimetallic)","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","of the supplied RS assembly kit":"3RA2913-1DB2","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-1HA20","degree of protection NEMA rating":"other","For Auxiliary And Control Circuit":"spring-loaded terminals","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Without Load Current Share Typical":"4.2 W","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"3.3 W","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","apparent holding power of magnet coil at AC":"4.2 VA","protocol is supported AS-Interface protocol":"No","with high demand rate according to SN 31920":"73 %","reference code according to IEC 81346-2:2019":"Q","shock resistance according to IEC 60068-2-27":"6g / 11 ms","Type Of Voltage Of The Control Supply Voltage":"AC","at 400 V according to IEC 60947-4-1 rated value":"150 000 A","Inductive Power Factor With The Holding Power Of The Coil":"0.25","Mechanical Service Life (Operating Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"104 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"5.5 ... 8 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b320ed7f28f1757339c381bc992d26d1.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=33318&mlfb=3RA2210-1HH15-2AP0"},"ai":{"faq":[{"question":"What is the trip class of this reversing starter?","answer":"CLASS 10 — the overload relay clears within 10 seconds at locked-rotor current, matching standard motor starting profiles."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2210-1HH15-2AP0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2210-1HH15-2AP0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}