{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2210-1JD16-2AK6","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2210-1JD16-2AK6","canonicalUrl":"https://aoctrl.com/siemens/3RA2210-1JD16-2AK6","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2210-1JD16-2AK6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2210-1JD16-2AK6 non-fused load feeder, reversing starter, Size S00, Class 10, thermal bimetallic overload, 4 kW at 400 V, 5 hp at 460/480 V, snap-on 60 mm busbar.","salesMarkdown":"## Reversing starter in a S00 frame — what the ratings mean on the line This 3RA2210-1JD16-2AK6 is a SIRIUS non-fused load feeder configured as a reversing starter — meaning it combines a contactor pair and a thermal overload relay in one unit sized S00, ready to reverse a three-phase motor without external interlocking wiring. The 7.6 A at 480 V and 9 A at 600 V give you the current ceiling for conductor sizing. ## Snap-on busbar mounting and panel fit Mounts by snapping directly onto a 60 mm busbar system — no DIN rail adapter needed, which saves a rail slot and keeps the busbar run continuous. The vertical mounting position is specified; horizontal mounting would change the thermal calibration of the bimetallic release. Dimensions are 155.1 mm deep × 90 mm wide × 200 mm tall. Clearance requirements: 20 mm upwards, 10 mm downwards, 9 mm at the sides, and zero forwards or backwards — so it fits tight against the back panel and the enclosure door. The supplied contactor is a 3RT2016-1AK62 and the link module is 3RA1921-1DA00 — these are the matched components inside the assembly, so ordering the feeder as a single code saves you sourcing three separate line items. ## Lifecycle and sourcing — current production, quoted to order Operating temperature range is -20 to +60 °C, storage and transport range -50 to +80 °C. Pollution degree 3 means it is rated for industrial environments with conductive pollution — typical for control panels without climate control. Substance prohibitance date of 10/01/2009 indicates RoHS compliance per the EU directive effective date — the part is RoHS-compliant for current builds.","metaTitle":"Siemens 3RA2210-1JD16-2AK6 SIRIUS Reversing Starter","metaDescription":"Siemens 3RA2210-1JD16-2AK6 SIRIUS reversing starter, Size S00, Class 10 thermal overload, rated 4 kW at 400 V. Active production, quoted to order. Request RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Starters"],"specifications":{"Depth":"155.1 mm","Width":"90 mm","title":"3RA2210-1JD16-2AK6","Height":"200 mm","Upwards":"20 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"690 V","description":"FUSELESS LOAD FEEDER REVERSING OPERATION, AC 400V, S00 7...10A, AC 110/120V 50/60HZ SCREW TERMINAL FOR BUSBAR SYSTEMS 60MM TYPE OF ASSIGNMENT 1,IQ = 150KA 1NC (CONTACTOR)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"for snapping onto 60 mm busbar systems","Mounting Position":"vertical","Product Brand Name":"SIRIUS","Type Of Assignment":"1","Degree Of Pollution":"3","Product Designation":"non-fused load feeders 3RA2","Size Of Load Feeder":"S00","at 400 V rated value":"4 000 W","at 480 V rated value":"7.6 A","at 50 Hz rated value":"110 V","at 500 V rated value":"5 500 W","at 60 Hz rated value":"120 V","at 600 V rated value":"9 A","at 690 V rated value":"7 500 W","Design Of The Product":"reversing starter","at 200/208 V rated value":"2 hp","at 220/230 V rated value":"3 hp","at 460/480 V rated value":"5 hp","at 575/600 V rated value":"7.5 hp","Of The Supplied Contactor":"3RT2016-1AK62","For Main Contacts Stranded":"0.5 ... 4 mm², 2x (0.75 ... 2.5 mm²)","Of The Supplied Link Module":"3RA1921-1DA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","Substance Prohibitance (Date)":"10/01/2009","Design Of The Overload Release":"thermal (bimetallic)","Of The Supplied Busbar Adapter":"8US1251-5DS10","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","at AWG cables for main contacts":"2x (20 ... 16), only for contactor 2x (18 ... 14), 2x 12","of the supplied RS assembly kit":"8US1250-5AS10","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-1JA10","Product Extension Auxiliary Switch":"Yes","Surge Voltage Resistance Rated Value":"6 kV","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","apparent holding power of magnet coil at AC":"4.2 VA","shock resistance according to IEC 60068-2-27":"6g / 11 ms","at 400 V according to IEC 60947-4-1 rated value":"153 000 A","at 500 V according to IEC 60947-4-1 rated value":"42 000 A","at 690 V according to IEC 60947-4-1 rated value":"4 000 A","operational current at AC-3 at 400 V rated value":"8.5 A","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","Mechanical Service Life (Switching Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"130 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"7 ... 10 A","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e782a08b41c5f264e00523d403086b31.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=510988&mlfb=3RA2210-1JD16-2AK6"},"ai":{"faq":[{"question":"What motor power does 3RA2210-1JD16-2AK6 handle at 400 V?","answer":"At 460/480 V the rating is 5 hp."},{"question":"Does this reversing starter include the contactor and overload relay?","answer":"Yes, it ships as a complete non-fused load feeder with the supplied contactor 3RT2016-1AK62 and link module 3RA1921-1DA00 integrated — no separate components to assemble."},{"question":"How does the Class 10 trip class affect motor protection?","answer":"This is fast enough to protect standard motors during a stall without tripping on normal acceleration."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2210-1JD16-2AK6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2210-1JD16-2AK6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}