{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2210-4AD18-2AP6","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2210-4AD18-2AP6","canonicalUrl":"https://aoctrl.com/siemens/3RA2210-4AD18-2AP6","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2210-4AD18-2AP6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2210-4AD18-2AP6 non-fused reversing motor starter, size S00, Class 10, 7.5 kW at 400 V AC-3, 690 V max, 90 mm width, 155.1 mm depth, 200 mm height, snaps onto 60 mm busbar.","salesMarkdown":"## Reversing starter for motor control panels The Siemens 3RA2210-4AD18-2AP6 is a non-fused reversing motor starter from the SIRIUS 3RA2 series, size S00 — it combines a reversing contactor pair and a Class 10 thermal overload relay in one compact assembly that snaps onto 60 mm busbar systems. ## What's in the box and how it mounts The unit ships with a 3RT2018-1AP62 contactor and a 3RA1921-1DA00 link module pre-assembled — no separate wiring between the contactor and overload block. Mounting is vertical only, snapping onto 60 mm busbar systems. Dimensions are 90 mm wide × 200 mm high × 155.1 mm deep, with 20 mm clearance needed above and 10 mm below for wiring access. ## Lifecycle and sourcing — current production, quoted to order RoHS compliance date is 03/01/2017 — the starter meets the substance restrictions in effect from that date.","metaTitle":"Siemens 3RA2210-4AD18-2AP6 reversing motor starter, S00","metaDescription":"Siemens SIRIUS 3RA2210-4AD18-2AP6 non-fused reversing motor starter, size S00, Class 10 trip, 7.5 kW at 400 V AC-3. Current production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Starters"],"specifications":{"Depth":"155.1 mm","Width":"90 mm","title":"3RA2210-4AD18-2AP6","Height":"200 mm","Upwards":"20 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"690 V","description":"FUSELESS MOTOR STARTER REVERSING OPERATION 600V AC SZ S00 11-16A 220/240V AC 50/60HZ SCREW CONNECTION FOR SNAPPING ONTO 60 MM BUSBAR SYSTEMS TYPE OF COORDINATION 1 1NC (PER CONTACTOR)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-55 ... +80 °C","Fastening Method":"for snapping onto 60 mm busbar systems","Mounting Position":"vertical","Product Brand Name":"SIRIUS","Type Of Assignment":"1","Degree Of Pollution":"3","Product Designation":"non-fused motor starter 3RA2","Size Of Load Feeder":"S00","at 230 V rated value":"2 hp","at 400 V rated value":"7 500 W","at 480 V rated value":"14 A","at 50 Hz rated value":"187 ... 242 V","at 500 V rated value":"7 500 W","at 60 Hz rated value":"192 ... 264 V","at 600 V rated value":"11 A","Design Of The Product":"reversing starter","at 110/120 V rated value":"1 hp","at 200/208 V rated value":"3 hp","at 220/230 V rated value":"5 hp","at 460/480 V rated value":"10 hp","at 575/600 V rated value":"10 hp","Of The Supplied Contactor":"3RT2018-1AP62","For Main Contacts Stranded":"0.5 ... 4 mm², 2x (0.75 ... 2.5 mm²)","Of The Supplied Link Module":"3RA1921-1DA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","Substance Prohibitance (Date)":"03/01/2017","Design Of The Overload Release":"thermal (bimetallic)","Of The Supplied Busbar Adapter":"8US1251-5DS10","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","at AWG cables for main contacts":"2x (20 ... 16), only for contactor 2x (18 ... 14), 2x 12","of the supplied RS assembly kit":"3RA2913-1DB1","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-4AA10","Product Extension Auxiliary Switch":"Yes","Surge Voltage Resistance Rated Value":"6 kV","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","apparent holding power of magnet coil at AC":"6.5 VA","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"0","shock resistance according to IEC 60068-2-27":"6g / 11 ms","at 400 V according to IEC 60947-4-1 rated value":"153 000 A","operational current at AC-3 at 400 V rated value":"15.5 A","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","Inductive Power Factor With The Holding Power Of The Coil":"0.25","Mechanical Service Life (Switching Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"208 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"11 ... 16 A","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/bca430db401f7b79ac9233196c1a1142.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=55844&mlfb=3RA2210-4AD18-2AP6"},"ai":{"faq":[{"question":"What is the physical size of the 3RA2210-4AD18-2AP6?","answer":"The starter measures 90 mm wide, 200 mm high, and 155.1 mm deep, and snaps onto 60 mm busbar systems with vertical mounting only."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2210-4AD18-2AP6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2210-4AD18-2AP6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}