{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2215-0HA15-2AK6","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2215-0HA15-2AK6","canonicalUrl":"https://aoctrl.com/siemens/3RA2215-0HA15-2AK6","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2215-0HA15-2AK6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS non-fused reversing motor starter 3RA2215-0HA15-2AK6, Size S00, Class 10, AC-3 rated 690 V, thermal bimetallic overload, snap-on DIN rail mount.","salesMarkdown":"The Siemens 3RA2215-0HA15-2AK6 is a SIRIUS non-fused reversing motor starter in Size S00 — a factory-assembled combination of a reversing contactor pair, a thermal bimetallic overload relay, and a magnetic short-circuit trip, all on a common footprint. It ships with the contactor 3RT2015-1AK62, the link module 3RA1921-1DA00, and the circuit-breaker 3RV2011-0HA15 pre-integrated. That means one order code delivers the complete forward/reverse motor branch, not a pile of loose components to coordinate yourself. Rated for AC-3 switching duty up to 690 V, with a Trip Class 10 thermal curve, this starter is sized for motor loads up to 180 W at 400 V, 250 W at 500 V, and 370 W at 690 V. The magnetic short-circuit element handles the high-fault clearing. Mounting is straightforward: snap it onto a DIN rail or screw-mount it using the additional push-in lug. The vertical mounting position is specified, and the unit needs 20 mm clearance upward, 10 mm downward, and 9 mm at the sides — tight enough for dense S00 panels. Operating temperature spans -20 to +60 °C, with wider storage and transport limits. When you need to confirm fit for a reversing motor application at 600 VAC, the AC-3 maximum rating of 690 V covers that voltage comfortably. The reversing contactor pair is mechanically interlocked inside the assembly, so the forward and main contactors cannot close simultaneously — a standard requirement for direction-change circuits. The auxiliary switch option (Product Extension Auxiliary Switch: Yes) allows feedback to a PLC or status lamp without adding a separate block. The 90 mm width and 170 mm height fit the Size S00 envelope — the smallest SIRIUS feeder size, designed for high-density layouts. Depth is 97.1 mm, which includes the overhang of the circuit-breaker handle and the contactor arc chambers. When planning gland-plate clearance, account for the full depth plus the 20 mm upward ventilation gap. The snap-on DIN rail mount lets you populate a row quickly; the screw-mount option is there if vibration or panel layout demands it. The main contact wiring accepts 0.5 to 4 mm² stranded, or 2× (0.75 to 2.5 mm²) for paralleled feeds. AWG equivalents are 2× (20–16) for the contactor terminals and 2× (18–14) plus 2× 12 for the larger lugs.","metaTitle":"Siemens 3RA2215-0HA15-2AK6 SIRIUS Reversing Starter","metaDescription":"Siemens 3RA2215-0HA15-2AK6 SIRIUS non-fused reversing motor starter, Size S00, Class 10, 690 V AC-3 max, thermal bimetallic overload. Current lifecycle stage.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Starters"],"specifications":{"Depth":"97.1 mm","Width":"90 mm","title":"3RA2215-0HA15-2AK6","Height":"170 mm","Upwards":"20 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"690 V","description":"Fuseless motor starter Reversing operation 600VAC Size S00 0.55-0.8A 110/120VAC 50/60HZ screw connection For screw mounting Or 35 mm rail-mounting Type of coordination 2 IQ = 150 KA Also full fills type Of coordination 1 1NO+1NC (MSP) 1NC (per contactor)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-55 ... +80 °C","Fastening Method":"Snap-mounted to DIN rail or screw-mounted with additional push-in lug","Mounting Position":"vertical","Product Brand Name":"SIRIUS","Type Of Assignment":"2","Degree Of Pollution":"3","Product Designation":"non-fused motor starter 3RA2","Size Of Load Feeder":"S00","at 400 V rated value":"180 W","at 50 Hz rated value":"93.5 ... 121 V","at 500 V rated value":"250 W","at 60 Hz rated value":"96 ... 132 V","at 690 V rated value":"370 W","Design Of The Product":"reversing starter","Of The Supplied Contactor":"3RT2015-1AK62","For Main Contacts Stranded":"0.5 ... 4 mm², 2x (0.75 ... 2.5 mm²)","Of The Supplied Link Module":"3RA1921-1DA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","Design Of The Overload Release":"thermal (bimetallic)","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","at AWG cables for main contacts":"2x (20 ... 16), only for contactor 2x (18 ... 14), 2x 12","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-0HA15","Product Extension Auxiliary Switch":"Yes","Surge Voltage Resistance Rated Value":"6 kV","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","apparent holding power of magnet coil at AC":"4.8 VA","number of NC contacts for auxiliary contacts":"2","number of NO contacts for auxiliary contacts":"1","shock resistance according to IEC 60068-2-27":"6g / 11 ms","at 400 V according to IEC 60947-4-1 rated value":"153 000 A","at 500 V according to IEC 60947-4-1 rated value":"100 000 A","at 690 V according to IEC 60947-4-1 rated value":"100 000 A","operational current at AC-3 at 400 V rated value":"0.6 A","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","Inductive Power Factor With The Holding Power Of The Coil":"0.25","Mechanical Service Life (Switching Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"10.4 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.55 ... 0.8 A","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4694693db8d5d177c5197c4d4bf1d75a.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=380864&mlfb=3RA2215-0HA15-2AK6"},"ai":{"faq":[{"question":"Where can I buy the 3RA2215-0HA15-2AK6 and what is the price?","answer":"This reversing starter is sourced to order against an RFQ through independent industrial-automation distribution. Pricing and lead time are confirmed at quote time — no stock count or list price is carried on this listing. Submit an RFQ for a current commercial offer."},{"question":"Does the 3RA2215-0HA15-2AK6 work with 600 VAC reversing applications?","answer":"Yes. The AC-3 rated maximum is 690 V, so 600 VAC falls within the rated operating range. The reversing contactor pair is mechanically interlocked inside the assembly, making it suitable for direction-change circuits at that voltage level."},{"question":"What is the difference between 3RA2215-0HA15-2AK6 and 3RA2215-0HA15-2AK4?","answer":"Both are SIRIUS Size S00 reversing starters with the same contactor and circuit-breaker platform. The suffix difference (2AK6 vs 2AK4) typically indicates a variation in the auxiliary contact configuration or coil voltage — the 2AK6 variant carries the specific auxiliary switch option (Product Extension Auxiliary Switch: Yes) and the coil voltage range of 93.5–121 V at 50 Hz / 96–132 V at 60 Hz. Confirm the exact coil and auxiliary contact count against your BOM before ordering."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2215-0HA15-2AK6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2215-0HA15-2AK6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}