{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2215-0HA15-2AP6","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2215-0HA15-2AP6","canonicalUrl":"https://aoctrl.com/siemens/3RA2215-0HA15-2AP6","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2215-0HA15-2AP6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2215-0HA15-2AP6 non-fused reversing motor starter, size S00, Class 10 thermal overload relay, 180 W at 400 V, 50/60 Hz, snap-on DIN rail mount.","salesMarkdown":"## Reversing starter for tight panels The 3RA2215-0HA15-2AP6: This is a Siemens SIRIUS 3RA2 non-fused reversing motor starter — a pre-assembled unit that combines a contactor, thermal overload relay, and short-circuit protection in one size S00 package. It's built for controlling reversing motor loads like conveyors, hoists, or valve actuators where you need forward/reverse switching without separate component wiring. Rated 180 W at 400 V and 370 W at 690 V, with a 50/60 Hz operating range. Snaps onto DIN rail or screws down with the included push-in lug. Mounting is vertical only — horizontal mounting changes the thermal behavior and voids the overload calibration. Dimensions: 170 mm tall, 90 mm wide, 97.1 mm deep, with 20 mm clearance needed above and 10 mm below for airflow and wiring. ## What's inside the box — supplied components The starter ships as a complete assembly: a 3RT2015-1AP62 contactor, a 3RA1921-1DA00 link module, and a 3RV2011-0HA15 circuit-breaker. That means the overload relay and magnetic short-circuit trip are already wired and coordinated — no guessing on the trip curve match. The contactor is electromechanical, the overload is thermal bimetallic, and the short-circuit trip is magnetic. Pollution degree 3 rated — fine for industrial control panels where dust and conductive deposits are present. AWG equivalents: 2x 20–16, or 2x 18–14, or 2x 12. The auxiliary switch extension is available (product extension auxiliary switch: Yes) if you need feedback to the PLC. ## Active production — sourcing this exact code No stock-holding claim — sourced per RFQ.","metaTitle":"Siemens 3RA2215-0HA15-2AP6 Reversing Motor Starter, S00","metaDescription":"Siemens SIRIUS 3RA2215-0HA15-2AP6 non-fused reversing motor starter, size S00, Class 10 thermal overload, 180W at 400V. Active production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Starters"],"specifications":{"Depth":"97.1 mm","Width":"90 mm","title":"3RA2215-0HA15-2AP6","Height":"170 mm","Upwards":"20 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"690 V","description":"Fuseless motor starter Reversing operation 600VAC Size S00 0.55-0.8A 220/240VAC 50/60HZ screw connection For screw mounting Or 35 mm rail-mounting Type of coordination 2 IQ = 150 KA Also full fills type Of coordination 1 1NO+1NC (MSP) 1NC (per contactor)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-55 ... +80 °C","Fastening Method":"Snap-mounted to DIN rail or screw-mounted with additional push-in lug","Mounting Position":"vertical","Product Brand Name":"SIRIUS","Type Of Assignment":"2","Degree Of Pollution":"3","Product Designation":"non-fused motor starter 3RA2","Size Of Load Feeder":"S00","at 400 V rated value":"180 W","at 50 Hz rated value":"187 ... 242 V","at 500 V rated value":"250 W","at 60 Hz rated value":"192 ... 264 V","at 690 V rated value":"370 W","Design Of The Product":"reversing starter","Of The Supplied Contactor":"3RT2015-1AP62","For Main Contacts Stranded":"0.5 ... 4 mm², 2x (0.75 ... 2.5 mm²)","Of The Supplied Link Module":"3RA1921-1DA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","Design Of The Overload Release":"thermal (bimetallic)","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","at AWG cables for main contacts":"2x (20 ... 16), only for contactor 2x (18 ... 14), 2x 12","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-0HA15","Product Extension Auxiliary Switch":"Yes","Surge Voltage Resistance Rated Value":"6 kV","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","apparent holding power of magnet coil at AC":"4.8 VA","number of NC contacts for auxiliary contacts":"2","number of NO contacts for auxiliary contacts":"1","shock resistance according to IEC 60068-2-27":"6g / 11 ms","at 400 V according to IEC 60947-4-1 rated value":"153 000 A","at 500 V according to IEC 60947-4-1 rated value":"100 000 A","at 690 V according to IEC 60947-4-1 rated value":"100 000 A","operational current at AC-3 at 400 V rated value":"0.6 A","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","Inductive Power Factor With The Holding Power Of The Coil":"0.25","Mechanical Service Life (Switching Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"10.4 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.55 ... 0.8 A","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":47,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9017a2fef30c7ca41c39746a4c777867.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=441353&mlfb=3RA2215-0HA15-2AP6"},"ai":{"faq":[{"question":"What are the power ratings at different voltages for this motor starter?","answer":"At 400 V it's rated 180 W, at 500 V it's 250 W, and at 690 V it's 370 W."},{"question":"What mounting clearances are needed around this starter?","answer":"Requires 20 mm clearance above, 10 mm below, 9 mm at the sides, and 0 mm forward/backward. Mounting is vertical only, snap-on DIN rail or screw mount with the included push-in lug."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2215-0HA15-2AP6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2215-0HA15-2AP6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}