{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2215-0HD15-2AK6","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2215-0HD15-2AK6","canonicalUrl":"https://aoctrl.com/siemens/3RA2215-0HD15-2AK6","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2215-0HD15-2AK6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2215-0HD15-2AK6 reversing motor starter, size S00, 180 W at 400 V, Class 10, 50/60 Hz, 690 V rated, snap-on 60 mm busbar.","salesMarkdown":"## Reversing starter, pre-assembled, size S00 The 3RA2215-0HD15-2AK6: This is a Siemens SIRIUS 3RA2 non-fused reversing motor starter, size S00, combining a contactor, a thermal bimetallic overload relay, and a magnetic short-circuit trip in one assembly. It ships with the contactor 3RT2015-1AK62, the circuit-breaker 3RV2011-0HA15, the link module 3RA1921-1DA00, the busbar adapter 8US1251-5DS10, and the RS assembly kit 3RA2913-1DB1 — everything needed to drop into a panel and wire up. ## Mounting and panel fit The starter snaps onto 60 mm busbar systems (the standard DIN-rail alternative for high-density panels) and measures 90 mm wide by 200 mm high by 155.1 mm deep. Clearance requirements: 20 mm upwards, 10 mm downwards, 9 mm at the sides, and nothing forward or backward — tight enough for a crowded enclosure if you respect the airflow gaps. Mounting position is vertical; the operating temperature range is -20 to +60 °C, with wider storage and transport limits of -50 to +80 °C and -55 to +80 °C respectively. Pollution degree 3 means it's rated for industrial environments with conductive dust or occasional condensation — no extra conformal coating needed for most panel builds.","metaTitle":"Siemens 3RA2215-0HD15-2AK6 SIRIUS reversing starter","metaDescription":"Siemens 3RA2215-0HD15-2AK6 SIRIUS reversing motor starter, size S00, 180 W at 400 V, Class 10 thermal overload. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Starters"],"specifications":{"Depth":"155.1 mm","Width":"90 mm","title":"3RA2215-0HD15-2AK6","Height":"200 mm","Upwards":"20 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"690 V","description":"Fuseless motor starter Reversing operation 600VAC Size S00 0.55-0.8A 110/120VAC 50/60HZ screw connection For snapping onto 60 mm busbar systems Type of coordination 2 IQ = 150 KA Also full fills type Of coordination 1 1NO+1NC (MSP) 1NC (per contactor)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-55 ... +80 °C","Fastening Method":"for snapping onto 60 mm busbar systems","Mounting Position":"vertical","Product Brand Name":"SIRIUS","Type Of Assignment":"2","Degree Of Pollution":"3","Product Designation":"non-fused motor starter 3RA2","Size Of Load Feeder":"S00","at 400 V rated value":"180 W","at 50 Hz rated value":"93.5 ... 121 V","at 500 V rated value":"250 W","at 60 Hz rated value":"96 ... 132 V","at 690 V rated value":"370 W","Design Of The Product":"reversing starter","Of The Supplied Contactor":"3RT2015-1AK62","Of The Supplied Link Module":"3RA1921-1DA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","Design Of The Overload Release":"thermal (bimetallic)","Of The Supplied Busbar Adapter":"8US1251-5DS10","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","of the supplied RS assembly kit":"3RA2913-1DB1","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-0HA15","Product Extension Auxiliary Switch":"Yes","Surge Voltage Resistance Rated Value":"6 kV","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","apparent holding power of magnet coil at AC":"4.8 VA","number of NC contacts for auxiliary contacts":"2","number of NO contacts for auxiliary contacts":"1","shock resistance according to IEC 60068-2-27":"6g / 11 ms","at 400 V according to IEC 60947-4-1 rated value":"153 000 A","at 500 V according to IEC 60947-4-1 rated value":"100 000 A","at 690 V according to IEC 60947-4-1 rated value":"100 000 A","operational current at AC-3 at 400 V rated value":"0.6 A","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","Inductive Power Factor With The Holding Power Of The Coil":"0.25","Mechanical Service Life (Operating Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"10.4 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Type Of Connectable Conductor Cross-Sections For Main Contacts Stranded":"0.5 ... 4 mm², 2x (0.75 ... 2.5 mm²)","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.55 ... 0.8 A","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3cad7f5f7bb900ffb74980db48e26f37.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=336588&mlfb=3RA2215-0HD15-2AK6"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2215-0HD15-2AK6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2215-0HD15-2AK6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}