{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2215-0JD15-2BB4","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2215-0JD15-2BB4","canonicalUrl":"https://aoctrl.com/siemens/3RA2215-0JD15-2BB4","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2215-0JD15-2BB4","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2215-0JD15-2BB4 non-fused reversing motor starter, S00 size, CLASS 10 thermal bimetallic overload, 690 V AC-3 max, 50/60 Hz, 200 x 90 x 155.1 mm.","salesMarkdown":"## SIRIUS S00 reversing starter — what's in the box The 3RA2215-0JD15-2BB4 is a Siemens SIRIUS non-fused reversing motor starter in the S00 frame size — it combines a reversing contactor assembly, a CLASS 10 thermal bimetallic overload relay, and a magnetic short-circuit trip in one package that snaps onto 60 mm busbar systems. It ships with the contactor 3RT2015-1BB42, the link module 3RA1921-1DA00, the circuit-breaker 3RV2011-0JA15, the busbar adapter 8US1251-5DS10, and the RS assembly kit 3RA2913-1DB1 — all pre-configured as a coordinated motor feeder. ## Panel space and mounting — S00 footprint The enclosure cutout needs 200 mm height, 90 mm width, and 155.1 mm depth — the S00 frame keeps the panel fill factor tight for a reversing starter with integral overload and short-circuit protection. Mounting is vertical only, with clearance requirements of 20 mm upward, 10 mm downward, 9 mm at the side, and zero forward/backward — meaning it can sit flush against a backplate or enclosure wall. The fastening method is designed for snapping onto 60 mm busbar systems, common in Siemens panel layouts and standard distribution boards. ## Motor duty ratings — AC-3 and power across voltages Rated for AC-3 switching duty up to 690 V maximum — at 400 V it handles 250 W, at 500 V it handles 370 W, at 690 V it handles 550 W, and at 575/600 V it is rated 0.5 hp. Line frequency compatibility is 50/60 Hz, covering both IEC and NEMA regions without derating. ## Environmental and wiring specs Operating temperature range is -20 to +60 °C, storage range is -50 to +80 °C, and transport range is -55 to +80 °C — suitable for unheated warehouses and container shipping. Degree of pollution is 3 (conductive pollution or dry non-conductive pollution that becomes conductive due to condensation), typical for industrial control panels not in sealed clean rooms.","metaTitle":"Siemens 3RA2215-0JD15-2BB4 SIRIUS reversing starter, S00","metaDescription":"Siemens 3RA2215-0JD15-2BB4 SIRIUS non-fused reversing motor starter, S00 frame, CLASS 10 thermal overload, 690 V AC-3 max. Active production; quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Starters"],"specifications":{"Depth":"155.1 mm","Width":"90 mm","title":"3RA2215-0JD15-2BB4","Height":"200 mm","Upwards":"20 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"24 V","description":"Fuseless motor starter Reversing operation 600VAC Size S00 0.7-1A 24V DC screw connection For snapping onto 60 mm busbar systems Type of coordination 2 IQ = 150 KA Also full fills type Of coordination 1 1NO+1NC (MSP) 1NC (per contactor)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-55 ... +80 °C","Fastening Method":"for snapping onto 60 mm busbar systems","Mounting Position":"vertical","Product Brand Name":"SIRIUS","Type Of Assignment":"2","Degree Of Pollution":"3","Product Designation":"non-fused motor starter 3RA2","Size Of Load Feeder":"S00","at 400 V rated value":"250 W","at 500 V rated value":"370 W","at 690 V rated value":"550 W","Design Of The Product":"reversing starter","at 575/600 V rated value":"0.5 hp","Of The Supplied Contactor":"3RT2015-1BB42","For Main Contacts Stranded":"0.5 ... 4 mm², 2x (0.75 ... 2.5 mm²)","Of The Supplied Link Module":"3RA1921-1DA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","Design Of The Overload Release":"thermal (bimetallic)","Of The Supplied Busbar Adapter":"8US1251-5DS10","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","at AWG cables for main contacts":"2x (20 ... 16), only for contactor 2x (18 ... 14), 2x 12","of the supplied RS assembly kit":"3RA2913-1DB1","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-0JA15","Product Extension Auxiliary Switch":"Yes","holding power of magnet coil at DC":"4 W","Surge Voltage Resistance Rated Value":"6 kV","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","number of NC contacts for auxiliary contacts":"2","number of NO contacts for auxiliary contacts":"1","shock resistance according to IEC 60068-2-27":"6g / 11 ms","at 400 V according to IEC 60947-4-1 rated value":"153 000 A","at 500 V according to IEC 60947-4-1 rated value":"100 000 A","at 690 V according to IEC 60947-4-1 rated value":"100 000 A","operational current at AC-3 at 400 V rated value":"0.85 A","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","Mechanical Service Life (Switching Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"13 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.7 ... 1 A","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$102.87","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3e08d9c772e593ea9baa2a1ec4509d84.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=298059&mlfb=3RA2215-0JD15-2BB4"},"ai":{"faq":[{"question":"What is the form factor of this reversing starter?","answer":"The 3RA2215-0JD15-2BB4 measures 200 mm high by 90 mm wide by 155.1 mm deep, S00 frame size. It mounts vertically and snaps onto 60 mm busbar systems with 20 mm upward and 10 mm downward clearance needed."},{"question":"What motor power can this starter handle at 400 V?","answer":"At 400 V AC-3 duty, the rated motor power is 250 W. At 500 V it is 370 W, at 690 V it is 550 W, and at 575/600 V it is 0.5 hp. The maximum switching voltage is 690 V."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2215-0JD15-2BB4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2215-0JD15-2BB4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}