{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2215-1BA16-2BB4","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2215-1BA16-2BB4","canonicalUrl":"https://aoctrl.com/siemens/3RA2215-1BA16-2BB4","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2215-1BA16-2BB4","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS reversing starter, 3RA2215-1BA16-2BB4, S00 frame, 2 A at 400 V AC-3, Class 10 thermal overload, screw and snap-on 35 mm DIN rail mounting.","salesMarkdown":"## S00 reversing starter — what ships inside The 3RA2215-1BA16-2BB4: This is a pre-assembled SIRIUS reversing starter combining a contactor, a thermal overload relay, and a mechanical interlock in one S00-frame package. The supplied contactor is a 3RT2016-1BB42 and the link module is a 3RA1921-1DA00 — both factory-integrated, so the reversing interlock timing is set and the wiring between the contactor and overload is internal. The thermal overload release is bimetallic, Class 10 trip — it protects standard motors against sustained overload without nuisance tripping on normal starting current. ## Panel fit and mounting clearances Dimensions are 170 mm high, 90 mm wide, 97 mm deep. Mounts vertically on 35 mm DIN rail via the snap-on foot or with screws through the mounting base — both methods are supported. The required clearances around the unit are: 50 mm above, 32 mm in front, 10 mm at the sides, 10 mm below, and 0 mm behind (the back sits flush against the mounting surface). Main circuit connections use screw-type terminals — torque them to the value printed on the contactor label. The S00 frame keeps the footprint compact for high-density panel layouts where multiple starters share a DIN rail. ## Environmental limits and storage Storage and transport tolerance spans -50 °C to +80 °C — the unit can sit in an unheated warehouse or truck without damage. The control supply is 24 V DC (24... 24 V rated value).","metaTitle":"Siemens 3RA2215-1BA16-2BB4 SIRIUS Reversing Starter","metaDescription":"Siemens 3RA2215-1BA16-2BB4 SIRIUS reversing starter, 2 A at 400 V AC-3, S00 frame, Class 10 thermal overload, screw/DIN-rail mount.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Starters"],"specifications":{"Depth":"97 mm","Width":"90 mm","title":"3RA2215-1BA16-2BB4","Height":"170 mm","Upwards":"50 mm","Forwards":"32 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"10 mm","Rated Value":"24 ... 24 V","description":"Load feeder fuseless, Reversing duty 400 V AC, Size S00 1.40...2.00 A 24 V DC screw terminal for installation on standard mounting rail (also fulfills type of coordination 1) Type of coordination 2, Iq = 150 kA 1 NC (contactor) 1 NO+1 NC (circuit breaker, transverse)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail","Mounting Position":"vertical","PROFIsafe protocol":"No","Product Brand Name":"SIRIUS","Type Of Assignment":"2","Product Designation":"Reversing starter","Size Of Load Feeder":"S00","PROFINET IO protocol":"No","at 230 V rated value":"0.16 hp","at 400 V rated value":"750 kW","at 480 V rated value":"2 A","at 600 V rated value":"2 A","Design Of The Product":"for standard rail or screw mounting","For Main Current Circuit":"screw-type terminals","Temperature Compensation":"-20 ... +60 °C","at 220/230 V rated value":"0.5 hp","at 460/480 V rated value":"1 hp","at 575/600 V rated value":"1.5 hp","Of The Supplied Contactor":"3RT2016-1BB42","Of The Supplied Link Module":"3RA1921-1DA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","at AC-3 at 400 V rated value":"2 A","at AC-3e rated value maximum":"690 V","at AC-3e at 400 V rated value":"2 A","Design Of The Overload Release":"thermal (bimetallic)","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-1BA15","degree of protection NEMA rating":"other","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Without Load Current Share Typical":"4 W","holding power of magnet coil at DC":"4 W","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"2.7 W","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","protocol is supported AS-Interface protocol":"No","with high demand rate according to SN 31920":"73 %","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","reference code according to IEC 81346-2:2019":"Q","shock resistance according to IEC 60068-2-27":"6g / 11 ms","Type Of Voltage Of The Control Supply Voltage":"DC","at 400 V according to IEC 60947-4-1 rated value":"150 000 A","Mechanical Service Life (Operating Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"26 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"1.4 ... 2 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/57d6a9f9595dc4193d197301644ee6f1.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=426920&mlfb=3RA2215-1BA16-2BB4"},"ai":{"faq":[{"question":"What is the AC-3 current rating of 3RA2215-1BA16-2BB4?","answer":"This rating governs motor switching duty for standard squirrel-cage induction motors."},{"question":"What compliance documentation does Siemens provide for 3RA2215-1BA16-2BB4?","answer":"The part carries Siemens standard documentation including CE declaration of conformity and RoHS compliance. Specific certificates (UL, CSA, IEC) are part of the SIRIUS series certification package — confirm the exact certs needed against the BOM requirements at RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2215-1BA16-2BB4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2215-1BA16-2BB4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}