{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2215-1EA15-2AP6","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2215-1EA15-2AP6","canonicalUrl":"https://aoctrl.com/siemens/3RA2215-1EA15-2AP6","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2215-1EA15-2AP6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2215-1EA15-2AP6 reversing motor starter, Size S00, non-fused design, Class 10 thermal bimetallic overload, AC-3 rated 690 V, 1.5 kW at 400 V, snap-on DIN rail.","salesMarkdown":"## Reversing starter in SIRIUS S00 frame The Siemens 3RA2215-1EA15-2AP6 is a reversing motor starter in the SIRIUS family, Size S00 frame — the compact footprint for load feeders up to 690 V AC-3. This is a non-fused design, meaning it relies on an upstream circuit breaker for short-circuit protection rather than integral fuses. It ships as a factory-assembled unit including the 3RT2015-1AP62 contactor and the 3RA1921-1DA00 link module, saving panel-build time over sourcing components separately. ## Class 10 thermal overload and AC-3 duty At 400 V AC-3 duty the starter is rated for 1.5 kW motor load; at 480 V it handles 3.95 A, and at 600 V 4 A — the current ceiling is consistent across the upper voltage range, limited by the S00 contactor thermal capacity rather than arc extinction. ## DIN rail snap-on with clearance for reversing The 90 mm width and 170 mm height fit a standard S00 cavity; depth is 97.1 mm including the contactor coil projection. Side clearance of 9 mm allows adjacent starters without thermal derating. Main contact wiring accepts stranded conductors 0.5–4 mm², or two conductors 0.75–2.5 mm² in parallel — flexible enough for mixed control and power circuits in a panel. ## Active production — current lifecycle stage Operating temperature range is -20 to +60 °C with storage from -50 to +80 °C — suitable for unheated industrial enclosures across most climate zones. Pollution degree 3 per IEC 60947-1 means it tolerates conductive dust and condensation typical of factory-floor control panels without conformal coating.","metaTitle":"Siemens 3RA2215-1EA15-2AP6 Motor Starter, Reversing, S00","metaDescription":"Siemens SIRIUS 3RA2215-1EA15-2AP6 reversing motor starter, Size S00, AC-3 rated 690 V max, Class 10 thermal overload, 1.5 kW at 400 V. Active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Starters"],"specifications":{"Depth":"97.1 mm","Width":"90 mm","title":"3RA2215-1EA15-2AP6","Height":"170 mm","Upwards":"20 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"690 V","description":"Fuseless motor starter Reversing operation 600VAC Size S00 2.8-4A 220/240VAC 50/60HZ screw connection For screw mounting Or 35 mm rail-mounting Type of coordination 2 IQ = 150 KA Also full fills type Of coordination 1 1NO+1NC (MSP) 1NC (per contactor)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-55 ... +80 °C","Fastening Method":"Snap-mounted to DIN rail or screw-mounted with additional push-in lug","Mounting Position":"vertical","Product Brand Name":"SIRIUS","Type Of Assignment":"2","Degree Of Pollution":"3","Product Designation":"non-fused motor starter 3RA2","Size Of Load Feeder":"S00","at 230 V rated value":"0.33 hp","at 400 V rated value":"1 500 W","at 480 V rated value":"3.95 A","at 50 Hz rated value":"187 ... 242 V","at 500 V rated value":"2 200 W","at 60 Hz rated value":"192 ... 264 V","at 600 V rated value":"4 A","Design Of The Product":"reversing starter","at 110/120 V rated value":"0.13 hp","at 200/208 V rated value":"0.75 hp","at 220/230 V rated value":"0.75 hp","at 460/480 V rated value":"2 hp","at 575/600 V rated value":"3 hp","Of The Supplied Contactor":"3RT2015-1AP62","For Main Contacts Stranded":"0.5 ... 4 mm², 2x (0.75 ... 2.5 mm²)","Of The Supplied Link Module":"3RA1921-1DA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","Design Of The Overload Release":"thermal (bimetallic)","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","at AWG cables for main contacts":"2x (20 ... 16), only for contactor 2x (18 ... 14), 2x 12","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-1EA15","Product Extension Auxiliary Switch":"Yes","Surge Voltage Resistance Rated Value":"6 kV","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","apparent holding power of magnet coil at AC":"4.8 VA","number of NC contacts for auxiliary contacts":"2","number of NO contacts for auxiliary contacts":"1","shock resistance according to IEC 60068-2-27":"6g / 11 ms","at 400 V according to IEC 60947-4-1 rated value":"153 000 A","operational current at AC-3 at 400 V rated value":"3.6 A","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","Inductive Power Factor With The Holding Power Of The Coil":"0.25","Mechanical Service Life (Switching Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"52 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"2.8 ... 4 A","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/40341ccfa719f6872d4dad4a21cec3f7.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=134981&mlfb=3RA2215-1EA15-2AP6"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2215-1EA15-2AP6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2215-1EA15-2AP6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}