{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2215-1JD16-2BB4","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2215-1JD16-2BB4","canonicalUrl":"https://aoctrl.com/siemens/3RA2215-1JD16-2BB4","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2215-1JD16-2BB4","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2215-1JD16-2BB4 non-fused reversing motor starter, size S00, CLASS 10 thermal bimetallic overload, 7.6 A at 480 V AC-3, 690 V max, 50-60 Hz, snaps onto 60 mm busbar.","salesMarkdown":"## Reversing starter in a size S00 package The 3RA2215-1JD16-2BB4 is a SIRIUS non-fused reversing motor starter — a combined contactor pair and thermal overload in one assembly, size S00 frame. It snaps onto 60 mm busbar systems and mounts vertically. Rated for AC-3 duty up to 690 V, it delivers 7.6 A at 480 V (5 hp) and 9 A at 600 V (7.5 hp) — the current values that govern motor switching, not the contactor's thermal continuous rating alone. ## Dimensions and panel fit At 200 mm high, 90 mm wide, and 155.1 mm deep, the S00 footprint fits standard 200 mm cabinet heights. Clearance needed: 20 mm above, 10 mm below, 9 mm at the side — no space required forward or backward of the mounting plane. AWG equivalent is 2 × 20...16 or single 12 AWG. The supplied contactor is a 3RT2016-1BB42, link module 3RA1921-1DA00, and busbar adapter 8US1251-5DS10. ## Active production — quoted per BOM Volume quantities are quoted to order against the BOM line.","metaTitle":"Siemens 3RA2215-1JD16-2BB4 SIRIUS Reversing Starter","metaDescription":"Siemens 3RA2215-1JD16-2BB4 SIRIUS non-fused reversing motor starter, size S00, CLASS 10 thermal overload, 7.6 A at 480 V AC-3.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Starters"],"specifications":{"Depth":"155.1 mm","Width":"90 mm","title":"3RA2215-1JD16-2BB4","Height":"200 mm","Upwards":"20 mm","Forwards":"0 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"24 V","description":"Fuseless motor starter Reversing operation 600VAC Size S00 7-10A 24V DC screw connection For snapping onto 60 mm busbar systems Type of coordination 1 1NO+1NC (MSP) 1NC (per contactor)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-55 ... +80 °C","Fastening Method":"for snapping onto 60 mm busbar systems","Mounting Position":"vertical","Product Brand Name":"SIRIUS","Type Of Assignment":"1","Degree Of Pollution":"3","Product Designation":"non-fused motor starter 3RA2","Size Of Load Feeder":"S00","at 400 V rated value":"4 000 W","at 480 V rated value":"7.6 A","at 500 V rated value":"5 500 W","at 600 V rated value":"9 A","Design Of The Product":"reversing starter","at 200/208 V rated value":"2 hp","at 220/230 V rated value":"3 hp","at 460/480 V rated value":"5 hp","at 575/600 V rated value":"7.5 hp","Of The Supplied Contactor":"3RT2016-1BB42","For Main Contacts Stranded":"0.5 ... 4 mm², 2x (0.75 ... 2.5 mm²)","Of The Supplied Link Module":"3RA1921-1DA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","Design Of The Overload Release":"thermal (bimetallic)","Of The Supplied Busbar Adapter":"8US1251-5DS10","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","at AWG cables for main contacts":"2x (20 ... 16), only for contactor 2x (18 ... 14), 2x 12","of the supplied RS assembly kit":"3RA2913-1DB1","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-1JA15","Product Extension Auxiliary Switch":"Yes","holding power of magnet coil at DC":"4 W","Surge Voltage Resistance Rated Value":"6 kV","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","number of NC contacts for auxiliary contacts":"2","number of NO contacts for auxiliary contacts":"1","shock resistance according to IEC 60068-2-27":"6g / 11 ms","at 400 V according to IEC 60947-4-1 rated value":"153 000 A","operational current at AC-3 at 400 V rated value":"8.5 A","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","Mechanical Service Life (Switching Cycles) Of Contactor Typical":"30 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"130 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"7 ... 10 A","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/dbbf8f102c1fe1335f48df7c5d4d7608.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=274705&mlfb=3RA2215-1JD16-2BB4"},"ai":{"faq":[{"question":"What is the 3RA2215-1JD16-2BB4 rated for at 480 V?","answer":"At 480 V AC-3 it is rated 7.6 A, corresponding to 5 hp. The maximum AC-3 voltage is 690 V; rated current at 600 V is 9 A (7.5 hp)."},{"question":"What clearance is needed around this reversing starter in a panel?","answer":"The S00 frame requires 20 mm above, 10 mm below, and 9 mm at the side. No space is needed forward or backward of the mounting surface."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2215-1JD16-2BB4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2215-1JD16-2BB4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}