{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2220-4AB26-0AP0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2220-4AB26-0AP0","canonicalUrl":"https://aoctrl.com/siemens/3RA2220-4AB26-0AP0","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2220-4AB26-0AP0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2220-4AB26-0AP0 reversing starter, S0 size, 16 A AC-3 at 400 V, Class 10 trip, screw terminals, DIN rail mount.","salesMarkdown":"## 16 A AC-3 reversing starter — what the rating means for your motor circuit The 3RA2220-4AB26-0AP0: This is a SIRIUS reversing starter, meaning it combines two contactors and an overload relay in one package to reverse a three-phase motor without external interlocking wiring. The AC-3 rating of 16 A at 400 V covers typical squirrel-cage motors up to about 7.5 kW — that's the current during starting and plugging, not just running load. ## Panel fit — S0 size and DIN rail mounting The S0 feeder size and dimensions — 120 mm deep, 90 mm wide, 265 mm tall — tell you it fits the standard S0 footprint. Mounting is on a 35 mm DIN rail via an adapter, with screw-mount option if the panel lacks a rail. Clearance needs: 50 mm above, 32 mm in front, 10 mm below, 10 mm at the sides. That front clearance is tight — make sure the enclosure door or gland plate doesn't crowd the terminals. The supplied contactor is 3RT2026-1AP00 and the link module is 3RA2921-1AA00 — both are standard SIRIUS S0 parts, so spares and replacements are straightforward to source. The operating temperature range of -20 to +60 °C covers most indoor panel environments; storage from -50 to +80 °C is typical for warehouse conditions.","metaTitle":"Siemens 3RA2220-4AB26-0AP0 SIRIUS Reversing Starter","metaDescription":"Siemens 3RA2220-4AB26-0AP0 SIRIUS reversing starter, 16 A at 400 V AC-3, Class 10 trip, S0 size. Active production, quoted to order. Request a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Starters"],"specifications":{"Depth":"120 mm","Width":"90 mm","Height":"265 mm","Upwards":"50 mm","Forwards":"32 mm","at 50 Hz":"0.25","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"10 mm","Rated Value":"690 V","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"On adapter for screw and snap-on mounting on 35 mm DIN rail","Mounting Position":"vertical","PROFIsafe protocol":"No","Product Brand Name":"SIRIUS","Type Of Assignment":"2","Product Designation":"Reversing starter","Size Of Load Feeder":"S0","PROFINET IO protocol":"No","at 230 V rated value":"2 hp","at 400 V rated value":"7 500 kW","at 480 V rated value":"16 A","at 50 Hz rated value":"230 ... 230 V","at 600 V rated value":"16 A","Design Of The Product":"for standard rail or screw mounting","For Main Current Circuit":"screw-type terminals","Temperature Compensation":"-20 ... +60 °C","at 110/120 V rated value":"1 hp","at 200/208 V rated value":"5 hp","at 220/230 V rated value":"5 hp","at 460/480 V rated value":"10 hp","Of The Supplied Contactor":"3RT2026-1AP00","Of The Supplied Link Module":"3RA2921-1AA00","Size Of The Circuit-Breaker":"S0","at AC-3 rated value maximum":"690 V","at AC-3 at 400 V rated value":"16 A","at AC-3e rated value maximum":"690 V","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"16 A","Design Of The Overload Release":"thermal (bimetallic)","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","of the supplied RH assembly kit":"3RA2923-1BB1","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2021-4AA10","degree of protection NEMA rating":"other","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Without Load Current Share Typical":"9.8 W","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"5 W","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","apparent holding power of magnet coil at AC":"9.8 VA","protocol is supported AS-Interface protocol":"No","with high demand rate according to SN 31920":"73 %","reference code according to IEC 81346-2:2019":"Q","shock resistance according to IEC 60068-2-27":"6g / 11 ms","Type Of Voltage Of The Control Supply Voltage":"AC","Of The Supplied Standard Mounting Rail Adapter":"3RA2922-1AA00","at 400 V according to IEC 60947-4-1 rated value":"150 000 A","Inductive Power Factor With The Holding Power Of The Coil":"0.25","Mechanical Service Life (Operating Cycles) Of Contactor Typical":"10 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"208 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"10 ... 16 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/cf02a8484ddb434bda165e91e4bb60a8.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=228966&mlfb=3RA2220-4AB26-0AP0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RA2220-4AB26-0AP0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2220-4AB26-0AP0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2220-4AB26-0AP0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}