{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2220-4DH27-0AP0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2220-4DH27-0AP0","canonicalUrl":"https://aoctrl.com/siemens/3RA2220-4DH27-0AP0","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2220-4DH27-0AP0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS reversing starter, 3RA2220-4DH27-0AP0, size S0, 25 A AC-3 at 400 V, Class 10, spring-loaded terminals, for 60 mm busbar systems.","salesMarkdown":"## Reversing starter for 60 mm busbar panels The Siemens 3RA2220-4DH27-0AP0 is a SIRIUS reversing starter in size S0, designed to snap onto 60 mm busbar systems — common in motor control centres where space is tight and reversing duty is needed (e.g., conveyor drives, pump direction change). ## Dimensions and integration The unit measures 260 mm high, 90 mm wide, and 165 mm deep — the depth is the critical clearance behind the panel face when mounted on the busbar. Clearance requirements: 50 mm upward, 32 mm forward, 10 mm downward, 10 mm at the side, and 0 mm backward — so the back of the enclosure can be tight against the busbar. ## Supplied components and compliance The reversing starter ships with a 3RT2027-2AP00 contactor and a 3RA2921-2AA00 link module — these are the matched pair for the S0 frame; ordering the starter as a unit avoids mismatched contactor/overload combinations. Operating temperature range -20 to +60 °C; storage and transport range -50 to +80 °C — suitable for most indoor industrial environments without derating.","metaTitle":"Siemens 3RA2220-4DH27-0AP0 Reversing Starter, 25 A AC-3, S0","metaDescription":"Siemens SIRIUS reversing starter, 25 A at 400 V AC-3, Class 10 trip, snaps onto 60 mm busbars. Active production — sourced per RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Starters"],"specifications":{"Depth":"165 mm","Width":"90 mm","title":"3RA2220-4DH27-0AP0","Height":"260 mm","Upwards":"50 mm","Forwards":"32 mm","at 50 Hz":"0.25","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"10 mm","Rated Value":"690 V","description":"Load feeder fuseless, Reversing duty 400 V AC, Size S0 18...25 A 230 V AC Spring-type terminal for 60 mm busbar systems (also fulfills type of coordination 1) Type of coordination 2, Iq = 150 kA 1 NO+1 NC (contactor)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-50 ... +80 °C","Fastening Method":"for snapping onto 60 mm busbar systems","Mounting Position":"vertical","PROFIsafe protocol":"No","Product Brand Name":"SIRIUS","Type Of Assignment":"2","Product Designation":"Reversing starter","Size Of Load Feeder":"S0","PROFINET IO protocol":"No","at 230 V rated value":"3 hp","at 400 V rated value":"11 000 kW","at 480 V rated value":"25 A","at 50 Hz rated value":"230 ... 230 V","at 600 V rated value":"25 A","Design Of The Product":"for 60 mm busbars","For Main Current Circuit":"spring-loaded terminals","Temperature Compensation":"-20 ... +60 °C","at 110/120 V rated value":"2 hp","at 200/208 V rated value":"7.5 hp","at 220/230 V rated value":"7.5 hp","at 460/480 V rated value":"20 hp","Of The Supplied Contactor":"3RT2027-2AP00","Of The Supplied Link Module":"3RA2921-2AA00","Size Of The Circuit-Breaker":"S0","at AC-3 rated value maximum":"690 V","at AC-3 at 400 V rated value":"25 A","at AC-3e rated value maximum":"690 V","Substance Prohibitance (Date)":"10/01/2009","at AC-3e at 400 V rated value":"25 A","Design Of The Overload Release":"thermal (bimetallic)","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","of the supplied RS assembly kit":"3RA2923-1DB2","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2021-4DA20","degree of protection NEMA rating":"other","For Auxiliary And Control Circuit":"spring-loaded terminals","Product Extension Auxiliary Switch":"Yes","Relative Humidity During Operation":"10 ... 95 %","Without Load Current Share Typical":"9.8 W","Surge Voltage Resistance Rated Value":"6 kV","at AC in hot operating state per pole":"5.8 W","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","apparent holding power of magnet coil at AC":"9.8 VA","protocol is supported AS-Interface protocol":"No","with high demand rate according to SN 31920":"73 %","reference code according to IEC 81346-2:2019":"Q","shock resistance according to IEC 60068-2-27":"6g / 11 ms","Type Of Voltage Of The Control Supply Voltage":"AC","at 400 V according to IEC 60947-4-1 rated value":"150 000 A","Inductive Power Factor With The Holding Power Of The Coil":"0.25","Mechanical Service Life (Operating Cycles) Of Contactor Typical":"10 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"325 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"18 ... 25 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1faebf3ad59f86a7f4450a084dbd51dc.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=62573&mlfb=3RA2220-4DH27-0AP0"},"ai":{"faq":[{"question":"What is 3RA2220-4DH27-0AP0's listed depth?","answer":"The depth is 165 mm — this is the dimension behind the panel face when the starter is snapped onto the 60 mm busbar."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2220-4DH27-0AP0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2220-4DH27-0AP0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}