{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2225-1GD24-0AP6","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2225-1GD24-0AP6","canonicalUrl":"https://aoctrl.com/siemens/3RA2225-1GD24-0AP6","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2225-1GD24-0AP6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2225-1GD24-0AP6 reversing motor starter, non-fused, Size S0, 690 V rated, Class 10 trip, 3 hp at 480 V AC-3, supplied with 3RT2024-1AP60 contactor and link module.","salesMarkdown":"## Reversing starter for motor control panels The 3RA2225-1GD24-0AP6 is a non-fused reversing motor starter from the SIRIUS family, designed for AC-3 switching duty up to 690 V. It integrates a reversing contactor pair and overload relay in a single Size S0 package, with the supplied 3RT2024-1AP60 contactor and link module pre-assembled. ## Motor ratings across voltage bands At 460/480 V AC-3 the unit delivers 3 hp (4.8 A); at 575/600 V it delivers 5 hp (6.3 A). The 50 Hz coil range is 176–242 V, the 60 Hz coil range is 192–264 V — the starter can be wired for either line frequency without a coil swap. The S0 frame size accepts stranded main conductors from 1 to 10 mm² (2× 2.5–6 mm²), which covers the wire gauge range for these motor currents. Mounting is vertical only, snapping onto 60 mm busbar systems, with 155 mm depth, 90 mm width, and 260 mm height — the depth fits standard 200 mm deep enclosures. ## Clearance and compliance notes Required clearances: 30 mm upward, 10 mm forward, 10 mm downward, 9 mm at the side, and 0 mm backward. Pollution degree 3 (conductive or dry non-conductive pollution that becomes conductive due to condensation) — suitable for industrial control panels without sealed enclosures. Substance prohibitance date is 03/01/2017 — the unit complies with RoHS and REACH requirements as of that date. Operating temperature range is -20 to +60 °C; storage range is -50 to +80 °C.","metaTitle":"Siemens 3RA2225-1GD24-0AP6 SIRIUS reversing starter","metaDescription":"Siemens SIRIUS 3RA2225-1GD24-0AP6 non-fused reversing motor starter, Class 10 trip, 3 hp at 480 V AC-3. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Starters"],"specifications":{"Depth":"155 mm","Width":"90 mm","title":"3RA2225-1GD24-0AP6","Height":"260 mm","Upwards":"30 mm","Forwards":"10 mm","Backwards":"0 mm","Downwards":"10 mm","Trip Class":"CLASS 10","At The Side":"9 mm","Rated Value":"690 V","description":"Fuseless motor starter Reversing operation 600VAC Size S0 4.5-6.3A 220/240VAC 50/60HZ screw connection For snapping onto 60 mm busbar systems Type of coordination 2 IQ = 150 KA Also full fills type Of coordination 1 1NO+1NC (MSP) 1NO+1NC (per contactor)","During Storage":"-50 ... +80 °C","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-55 ... +80 °C","Fastening Method":"for snapping onto 60 mm busbar systems","Mounting Position":"vertical","Product Brand Name":"SIRIUS","Type Of Assignment":"2","Degree Of Pollution":"3","Product Designation":"non-fused motor starter 3RA2","Size Of Load Feeder":"S0","at 230 V rated value":"0.5 hp","at 400 V rated value":"2 200 W","at 480 V rated value":"4.8 A","at 50 Hz rated value":"176 ... 242 V","at 500 V rated value":"3 000 W","at 60 Hz rated value":"192 ... 264 V","at 600 V rated value":"6.3 A","Design Of The Product":"reversing starter","at 110/120 V rated value":"0.25 hp","at 200/208 V rated value":"1 hp","at 220/230 V rated value":"1.5 hp","at 460/480 V rated value":"3 hp","at 575/600 V rated value":"5 hp","Of The Supplied Contactor":"3RT2024-1AP60","For Main Contacts Stranded":"1 ... 10 mm², 2x (2.5 ... 6 mm²)","Of The Supplied Link Module":"3RA2921-1AA00","Size Of The Circuit-Breaker":"S00","at AC-3 rated value maximum":"690 V","Substance Prohibitance (Date)":"03/01/2017","Design Of The Overload Release":"thermal (bimetallic)","Of The Supplied Busbar Adapter":"8US1251-5NT10","Design Of The Switching Contact":"electromechanical","Operating Frequency Rated Value":"50 ... 60 Hz","at AWG cables for main contacts":"2x (16 ... 12), 2x (14 ... 8)","of the supplied RS assembly kit":"3RA2923-1DB1","Design Of The Short-Circuit Trip":"magnetic","Of The Supplied Circuit-Breakers":"3RV2011-1GA15","Product Extension Auxiliary Switch":"Yes","Surge Voltage Resistance Rated Value":"6 kV","Number Of Poles For Main Current Circuit":"3","Product Function Short Circuit Protection":"Yes","apparent holding power of magnet coil at AC":"7.2 VA","number of NC contacts for auxiliary contacts":"3","number of NO contacts for auxiliary contacts":"3","shock resistance according to IEC 60068-2-27":"6g / 11 ms","at 400 V according to IEC 60947-4-1 rated value":"153 000 A","at 500 V according to IEC 60947-4-1 rated value":"100 000 A","operational current at AC-3 at 400 V rated value":"5 A","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","Inductive Power Factor With The Holding Power Of The Coil":"0.28","Mechanical Service Life (Switching Cycles) Of Contactor Typical":"10 000 000","Response Value Current Of Instantaneous Short-Circuit Trip Unit":"81.9 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"4.5 ... 6.3 A","Connectable Conductor Cross-Section For Main Contacts Finely Stranded With Core End Processing":"1 ... 6 mm²"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/bbb3df6c36a0275cfcf6209a28ff4be0.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=457475&mlfb=3RA2225-1GD24-0AP6"},"ai":{"faq":[{"question":"What is the 3RA2225-1GD24-0AP6 rated for at 480 V?","answer":"At 460/480 V AC-3, the reversing starter delivers 3 hp (4.8 A). The maximum rated voltage is 690 V."},{"question":"What compliance documentation does this brand provide for 3RA2225-1GD24-0AP6?","answer":"The unit has a substance prohibitance date of 03/01/2017, indicating compliance with RoHS and REACH. It is designed for pollution degree 3 and rated for industrial control panel environments."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2225-1GD24-0AP6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2225-1GD24-0AP6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}