{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2316-8XB30-1BW4","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2316-8XB30-1BW4","canonicalUrl":"https://aoctrl.com/siemens/3RA2316-8XB30-1BW4","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2316-8XB30-1BW4","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2316-8XB30-1BW4 reversing contactor assembly, size S00, 4 kW at 400 V AC-3, screw-type terminals, 90 x 68 x 73 mm, snap-on DIN rail.","salesMarkdown":"The 3RA2316-8XB30-1BW4: It ships with two 3RT2016-1BW42 contactors mechanically interlocked, so it handles forward-reverse motor control without extra external wiring. ## Motor ratings that fit the panel At 460/480 V it's rated 5 hp, and at 575/600 V it's rated 7.5 hp. The contactor assembly handles up to 690 V AC-3 maximum, so it covers 400 V through 690 V motor circuits common in North American and European panels. The S00 frame measures 90 mm wide by 68 mm high by 73 mm deep, fitting standard 35 mm DIN rail with screw or snap-on mounting. Clearance around the unit: 6 mm upwards, forwards, downwards, and to the side; 0 mm backwards — meaning it can sit flush against the back panel. The magnet coil and main current circuit both use screw-type terminals, so no special tooling needed for installation.","metaTitle":"Siemens 3RA2316-8XB30-1BW4 SIRIUS Reversing Contactor, S00","metaDescription":"Siemens 3RA2316-8XB30-1BW4 SIRIUS reversing contactor assembly, S00 size, 4 kW at 400 V AC-3. Active production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Starters"],"specifications":{"Depth":"73 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²","Width":"90 mm","at AC":"10,5g / 5 ms, 6,6g / 10 ms","at DC":"10,5g / 5 ms, 6,6g / 10 ms","Height":"68 mm","Upwards":"6 mm","Forwards":"6 mm","Backwards":"0 mm","Downwards":"6 mm","At The Side":"6 mm","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","at AC-3 maximum":"750 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail","at AC-3e maximum":"750 1/h","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","at DC rated value":"48 V","Product Brand Name":"SIRIUS","Product Designation":"Reversing contactor assembly","Of Contactor Typical":"10 000 000","at 400 V rated value":"4 kW","at 480 V rated value":"7.6 A","at 500 V rated value":"4 kW","at 600 V rated value":"9 A","at 690 V rated value":"5.5 kW","For Main Current Circuit":"screw-type terminals","at 200/208 V rated value":"2 hp","at 220/230 V rated value":"3 hp","at 460/480 V rated value":"5 hp","at 575/600 V rated value":"7.5 hp","1 Of The Supplied Contactor":"3RT2016-1BW42","2 Of The Supplied Contactor":"3RT2016-1BW42","at AC-3 rated value maximum":"690 V","at AC-3e rated value maximum":"690 V","at AC-4 at 400 V rated value":"4 kW","Substance Prohibitance (Date)":"10/01/2009","at AWG cables for main contacts":"2x (20 ... 16), 2x (18 ... 14)","of the supplied RH assembly kit":"3RA2913-2AA1","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","Product Function Bus Communication":"Yes","With Type Of Assignment 2 Required":"gG NH 3NA, DIAZED 5SB, NEOZED 5SE: 20 A","closing power of magnet coil at DC":"4 W","holding power of magnet coil at DC":"4 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG NH 3NA, DIAZED 5SB, NEOZED 5SE: 35 A","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"< 1 error per 100 million operating cycles","with low demand rate according to SN 31920":"40 %","protocol is supported AS-Interface protocol":"No","with high demand rate according to SN 31920":"75 %","Type Of Voltage Of The Control Supply Voltage":"DC","contact rating of auxiliary contacts according to UL":"A600 / Q600","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","product function control circuit interface with IO link":"No","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gG: 10 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/0ea97292c2534bde35ae0de424021962.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=521108&mlfb=3RA2316-8XB30-1BW4","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RA2316-8XB30-1BW4/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2316-8XB30-1BW4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2316-8XB30-1BW4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}