{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2316-8XB34-1CK2","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2316-8XB34-1CK2","canonicalUrl":"https://aoctrl.com/siemens/3RA2316-8XB34-1CK2","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2316-8XB34-1CK2","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2316-8XB34-1CK2 reversing contactor assembly, S00 frame, 4 kW at 400 V AC-3, screw terminals, 90 mm width, 130 mm depth, 68 mm height, snap-on 35 mm DIN rail.","salesMarkdown":"## AC-4 switching and mechanical life The 3RA2316-8XB34-1CK2: The contactor withstands shock loads of 10.5 g at 5 ms and 6.6 g at 10 ms in both AC and DC directions, which is relevant for installations on mobile equipment or near heavy impact machinery. ## Mounting flexibility and terminal details Dimensions: 90 mm wide, 130 mm deep, 68 mm high — the S00 footprint is the smallest SIRIUS contactor frame, saving DIN rail space in dense panels. ## Sourcing and lifecycle — current production RoHS compliance date is listed as 07/01/2006 (the EU RoHS effective date), confirming the assembly meets the substance restrictions for sale in the European market.","metaTitle":"Siemens 3RA2316-8XB34-1CK2 SIRIUS reversing contactor, S00","metaDescription":"Siemens 3RA2316-8XB34-1CK2 reversing contactor assembly, SIRIUS S00 frame, rated 4 kW at 400 V AC-3.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Starters"],"specifications":{"Depth":"130 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²","Width":"90 mm","at AC":"10,5g / 5 ms, 6,6g / 10 ms","at DC":"10,5g / 5 ms, 6,6g / 10 ms","title":"3RA2316-8XB34-1CK2","Height":"68 mm","Upwards":"6 mm","Forwards":"6 mm","at 50 Hz":"0.25","at 60 Hz":"0.85 ... 1.1","Backwards":"0 mm","Downwards":"6 mm","At The Side":"6 mm","description":"reversing contactor assembly, AC-3e/AC-3, 9 A, 4 kW / 400 V, 3-pole, 120 V AC, 50/60 Hz, with varistor plugged on, screw terminal, electrical and mechanical interlock, 2 x auxiliary switch plugged on, auxiliary contacts: 2 x 2 NO + 2 NC","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Reversing contactor assembly","Of Contactor Typical":"10 000 000","at 400 V rated value":"4 kW","at 480 V rated value":"7.6 A","at 50 Hz rated value":"120 V","at 500 V rated value":"4 kW","at 60 Hz rated value":"120 V","at 600 V rated value":"9 A","at 690 V rated value":"5.5 kW","Instantaneous Contact":"4","For Main Current Circuit":"screw-type terminals","at 200/208 V rated value":"2 hp","at 220/230 V rated value":"3 hp","at 460/480 V rated value":"5 hp","at 575/600 V rated value":"7.5 hp","Per Direction Of Rotation":"2","at AC-4 at 400 V rated value":"4 kW","Substance Prohibitance (Date)":"07/01/2006","Design Of The Surge Suppressor":"with varistor","at AWG cables for main contacts":"2x (20 ... 16), 2x (18 ... 14)","of the supplied RH assembly kit":"3RA2913-2AA1","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","Product Function Bus Communication":"Yes","With Type Of Assignment 2 Required":"gG NH 3NA, DIAZED 5SB, NEOZED 5SE: 20 A","At Contactor For Auxiliary Contacts":"Screw-type terminals","operating frequency at AC-3 maximum":"750 1/h","With Type Of Coordination 1 Required":"gG NH 3NA, DIAZED 5SB, NEOZED 5SE: 35 A","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"< 1 error per 100 million operating cycles","with low demand rate according to SN 31920":"40 %","protocol is supported AS-Interface protocol":"No","with high demand rate according to SN 31920":"75 %","Type Of Voltage Of The Control Supply Voltage":"AC","operating voltage at AC-3 rated value maximum":"690 V","contact rating of auxiliary contacts according to UL":"A600 / Q600","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","product function control circuit interface with IO link":"No","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gG: 10 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$90.17","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7a0b623ffd8ec2e5a4f4d0ed11d27c76.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=155116&mlfb=3RA2316-8XB34-1CK2"},"ai":{"faq":[{"question":"What is the 3RA2316-8XB34-1CK2 used for?","answer":"It is a reversing contactor assembly used to control the direction of three-phase motors — forward/reverse for conveyors, hoists, pumps, fans, and any application that needs to swap rotation without a separate reversing starter."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2316-8XB34-1CK2","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2316-8XB34-1CK2 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}