{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2325-8XB30-2AK6","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2325-8XB30-2AK6","canonicalUrl":"https://aoctrl.com/siemens/3RA2325-8XB30-2AK6","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2325-8XB30-2AK6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS reversing contactor assembly, 3RA2325-8XB30-2AK6, S0 frame, 7.5 kW at 400 V AC-3, spring-type terminals, 2 x 3RT2025-2AK60 contactors, 90 x 114 x 97 mm.","salesMarkdown":"## Reversing a motor in a panel — what this assembly delivers The 3RA2325-8XB30-2AK6 is a SIRIUS reversing contactor assembly — two mechanically interlocked 3RT2025-2AK60 contactors in one package, one per direction of rotation, so forward and reverse are never energised simultaneously. ## Termination and wiring — spring terminals front to back Main circuit connections use spring-loaded terminals; the magnet coil also lands on spring-type terminals — no screw torque to verify, just push the ferrule in and go. ## Duty ratings and mechanical endurance AC-4 rating at 400 V is also 7.5 kW — the same as AC-3 here, so plugging or inching duty at rated power is within the contactor's capability, not derated. Mechanical life is 10,000,000 operations typical per contactor — the interlock mechanism shares that life; expect the assembly to outlast most machine rebuild cycles. Shock resistance is specified at 11.8 g / 5 ms and 7.4 g / 10 ms on AC, 15 g / 5 ms and 10 g / 10 ms on DC — suitable for panel mounting on a machine frame subject to vibration. ## Sourcing and lifecycle — active line, quoted to order No stock-holding claim — quoted per order.","metaTitle":"Siemens 3RA2325-8XB30-2AK6 SIRIUS Reversing Contactor","metaDescription":"Siemens SIRIUS reversing contactor assembly 3RA2325-8XB30-2AK6, 7.5 kW at 400 V AC-3, S0 frame, spring terminals, current production, available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Starters"],"specifications":{"Depth":"97 mm","Solid":"2x (1 ... 10 mm²)","Width":"90 mm","at AC":"11,8g / 5 ms, 7,4g / 10 ms","at DC":"15g / 5 ms, 10g / 10 ms","title":"3RA2325-8XB30-2AK6","Height":"114 mm","Upwards":"6 mm","Forwards":"6 mm","at 50 Hz":"0.25","at 60 Hz":"0.8 ... 1.1","Backwards":"0 mm","Downwards":"6 mm","At The Side":"6 mm","description":"reversing contactor assembly, AC-3e/AC-3, 17 A, 7.5 kW / 400 V, 3-pole, 110 V AC, 50 Hz / 120 V, 60 Hz, spring-loaded terminal, electrical and mechanical interlock, auxiliary contacts: 2 x 1 NO","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Spring-type terminals","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S0","Solid Or Stranded":"2x (0.5 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Reversing contactor assembly","Of Contactor Typical":"10 000 000","at 400 V rated value":"7.5 kW","at 480 V rated value":"14 A","at 50 Hz rated value":"110 V","at 500 V rated value":"7.5 kW","at 60 Hz rated value":"120 V","at 600 V rated value":"17 A","at 690 V rated value":"11 kW","Instantaneous Contact":"2","For Main Current Circuit":"spring-loaded terminals","at 220/230 V rated value":"5 hp","at 460/480 V rated value":"10 hp","at 575/600 V rated value":"15 hp","Per Direction Of Rotation":"1","1 Of The Supplied Contactor":"3RT2025-2AK60","2 Of The Supplied Contactor":"3RT2025-2AK60","at AC-4 at 400 V rated value":"7.5 kW","Substance Prohibitance (Date)":"10/01/2009","at AWG cables for main contacts":"1x (18 ... 8)","of the supplied RH assembly kit":"3RA2923-2AA2","For Auxiliary And Control Circuit":"spring-loaded terminals","Product Extension Auxiliary Switch":"Yes","Product Function Bus Communication":"Yes","With Type Of Assignment 2 Required":"gG NH 3NA, DIAZED 5SB, NEOZED 5SE: 25 A","At Contactor For Auxiliary Contacts":"Spring-type terminals","operating frequency at AC-3 maximum":"1 000 1/h","With Type Of Coordination 1 Required":"gG NH 3NA, DIAZED 5SB, NEOZED 5SE: 63 A","at AWG cables for auxiliary contacts":"2x (20 ... 14)","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"< 1 error per 100 million operating cycles","with low demand rate according to SN 31920":"40 %","Finely Stranded Without Core End Processing":"2x (0.5 ... 1.5 mm²)","protocol is supported AS-Interface protocol":"No","with high demand rate according to SN 31920":"75 %","Type Of Voltage Of The Control Supply Voltage":"AC","operating voltage at AC-3 rated value maximum":"690 V","contact rating of auxiliary contacts according to UL":"A600 / Q600","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","product function control circuit interface with IO link":"No","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gG: 10 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b661b81ea7d81788a7661c218316281c.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=139811&mlfb=3RA2325-8XB30-2AK6"},"ai":{"faq":[{"question":"What is 3RA2325-8XB30-2AK6's depth on this Motor Starters line?","answer":"The depth is 97 mm, with a width of 90 mm and height of 114 mm — fits a standard DIN rail enclosure with room for finger-safe wiring."},{"question":"What compliance documentation does Siemens provide for 3RA2325-8XB30-2AK6?","answer":"The evidence does not list specific compliance documents (RoHS, REACH, UL, IEC) for this exact order code. Standard SIRIUS components typically carry CE and UL/CSA markings, but verify the specific declaration for your shipment."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2325-8XB30-2AK6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2325-8XB30-2AK6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}