{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2325-8XD30-1DE4","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2325-8XD30-1DE4","canonicalUrl":"https://aoctrl.com/siemens/3RA2325-8XD30-1DE4","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2325-8XD30-1DE4","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2325-8XD30-1DE4 reversing contactor assembly, S0 frame size, 7.5 kW at 400 V AC-3, 14 A at 480 V, 11 kW at 690 V, screw-type terminals, varistor surge suppression, 35 mm DIN rail snap-on.","salesMarkdown":"## S0 reversing contactor assembly — two 3RT2025 contactors, one mechanical interlock The 3RA2325-8XD30-1DE4: This is a pre-assembled SIRIUS reversing contactor — two 3RT2025-1BE40 contactors on a common base with a mechanical interlock so both directions cannot close together. ## DIN rail mounting and wiring clearance Snaps onto 35 mm standard mounting rail with the screw-and-snap method. The S0 frame footprint is 90 mm wide, 101 mm tall, 107 mm deep — that depth sits well within a 200 mm enclosure but check the gland-plate clearance if the panel is shallow. For spacing, allow 6 mm upwards, forwards, downwards, and sideways; zero clearance needed backwards. ## Terminal capacity — main and coil circuits AWG equivalents for main contacts are 2x (16...12) and 2x (14...8). All main terminals are screw-type. The magnet coil also uses screw-type terminals — consistent termination method across the assembly, no mixing spring and screw on the same device. ## Built-in surge suppression and environmental limits The surge suppressor is a varistor type — it clips voltage transients from the coil circuit, which matters when the contactor shares a control transformer with PLC outputs or other sensitive loads. Shock resistance is rated at 11.8 g / 5 ms and 7.4 g / 10 ms for AC, 15 g / 5 ms and 10 g / 10 ms for DC — the DC shock rating is higher because the contactor holds in without AC zero-cross chatter. Mechanical life of the contactor is 10 million operating cycles typical — the reversing assembly shares that life rating since it uses the same contactor mechanism.","metaTitle":"Siemens 3RA2325-8XD30-1DE4 SIRIUS Reversing Contactor","metaDescription":"Siemens 3RA2325-8XD30-1DE4 SIRIUS reversing contactor assembly, S0 frame, 7.5 kW at 400 V AC-3, 14 A at 480 V. Active production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Starters"],"specifications":{"Depth":"107 mm","Solid":"2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²)","Width":"90 mm","at AC":"11,8g / 5 ms, 7,4g / 10 ms","at DC":"15g / 5 ms, 10g / 10 ms","title":"3RA2325-8XD30-1DE4","Height":"101 mm","Upwards":"6 mm","Forwards":"6 mm","Backwards":"0 mm","Downwards":"6 mm","At The Side":"6 mm","description":"reversing contactor assembly, AC-3e/AC-3, 17 A, 7.5 kW / 400 V, 3-pole, 60 V DC, with plugged-in varistor, screw terminal, electrical and mechanical interlock, 2 x auxiliary switch plugged on, auxiliary contacts: 2 x 3 NO + 2 NC","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S0","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","at DC rated value":"60 V","Product Brand Name":"SIRIUS","Product Designation":"Reversing contactor assembly","Of Contactor Typical":"10 000 000","at 400 V rated value":"7.5 kW","at 480 V rated value":"14 A","at 500 V rated value":"7.5 kW","at 600 V rated value":"17 A","at 690 V rated value":"11 kW","Instantaneous Contact":"2","For Main Current Circuit":"screw-type terminals","at 220/230 V rated value":"5 hp","at 460/480 V rated value":"10 hp","at 575/600 V rated value":"15 hp","Per Direction Of Rotation":"1","1 Of The Supplied Contactor":"3RT2025-1BE40","2 Of The Supplied Contactor":"3RT2025-1BE40","at AC-4 at 400 V rated value":"7.5 kW","Substance Prohibitance (Date)":"07/01/2006","Design Of The Surge Suppressor":"with varistor","at AWG cables for main contacts":"2x (16 ... 12), 2x (14 ... 8)","of the supplied RH assembly kit":"3RA2923-2AA1","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"Yes","Product Function Bus Communication":"Yes","With Type Of Assignment 2 Required":"gG NH 3NA, DIAZED 5SB, NEOZED 5SE: 25 A","closing power of magnet coil at DC":"5.9 W","holding power of magnet coil at DC":"5.9 W","At Contactor For Auxiliary Contacts":"Screw-type terminals","operating frequency at AC-3 maximum":"1 000 1/h","With Type Of Coordination 1 Required":"gG NH 3NA, DIAZED 5SB, NEOZED 5SE: 63 A","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"< 1 error per 100 million operating cycles","with low demand rate according to SN 31920":"40 %","protocol is supported AS-Interface protocol":"No","with high demand rate according to SN 31920":"75 %","Type Of Voltage Of The Control Supply Voltage":"DC","operating voltage at AC-3 rated value maximum":"690 V","contact rating of auxiliary contacts according to UL":"A600 / Q600","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","product function control circuit interface with IO link":"No","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gG: 10 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b661b81ea7d81788a7661c218316281c.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=913906&mlfb=3RA2325-8XD30-1DE4"},"ai":{"faq":[{"question":"What is the 3RA2325-8XD30-1DE4 rated for at 400 V?","answer":"7.5 kW in AC-3 duty and 7.5 kW in AC-4 reversing duty at 400 V. The AC-4 rating governs applications with frequent starts or reversing cycles."},{"question":"What wire sizes does the 3RA2325-8XD30-1DE4 accept on the main terminals?","answer":"AWG equivalents are 2x (16...12) and 2x (14...8)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2325-8XD30-1DE4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2325-8XD30-1DE4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}