{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2415-8XF31-1AP0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2415-8XF31-1AP0","canonicalUrl":"https://aoctrl.com/siemens/3RA2415-8XF31-1AP0","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2415-8XF31-1AP0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2415-8XF31-1AP0 contactor assembly for star-delta (wye-delta) motor starting, size S00, 5.5 kW at 400 V AC-3, 3x 3RT2015-1AP01 contactors, screw terminals, DIN rail mount.","salesMarkdown":"## Star-delta starter assembly — what's inside The 3RA2415-8XF31-1AP0: This is a pre-assembled SIRIUS contactor set for star-delta (wye-delta) motor starting, size S00. It ships with three 3RT2015-1AP01 contactors and the RS assembly kit 3RA2913-2BB1 — you mount it as a unit, not piece by piece. That covers the common European 400 V motor frame and steps up to 690 V for mining or heavy industrial feeds. ## Mounting and panel fit Dimensions are 68 mm high, 135 mm wide, 145 mm deep — the depth is the key constraint when the gland plate is tight. Clearance around the unit: 6 mm upwards, forwards, downwards, and to the side; 0 mm backwards (flush to the rail). That 0 mm rear clearance means it sits tight against the backplane — no extra breathing space needed behind the DIN rail. ## Termination and wiring Main current circuit, auxiliary/control circuit, and magnet coil all use screw-type terminals. ## Environmental and compliance Operates from -25 to +60 °C; stores from -55 to +80 °C. RoHS compliance date (substance prohibition) is 10/01/2009 — it meets the EU RoHS cutoff. No auxiliary switch fitted as standard (product extension auxiliary switch: No), so if you need a feedback contact, add it separately.","metaTitle":"Siemens 3RA2415-8XF31-1AP0 SIRIUS Star-Delta Starter","metaDescription":"Siemens 3RA2415-8XF31-1AP0 SIRIUS contactor assembly for star-delta motor starting. Rated 5.5 kW at 400 V AC-3, size S00, 3x 3RT2015-1AP01 contactors included.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Starters"],"specifications":{"Depth":"145 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²","Width":"135 mm","at AC":"10,5g / 5 ms, 6,6g / 10 ms","at DC":"10,5g / 5 ms, 6,6g / 10 ms","title":"3RA2415-8XF31-1AP0","Height":"68 mm","Upwards":"6 mm","Forwards":"6 mm","at 50 Hz":"0.25","at 60 Hz":"0.25","Backwards":"0 mm","Downwards":"6 mm","At The Side":"6 mm","description":"Contactor assembly for star-delta (wye-delta) start AC-3, 5.5 kW/400 V, 230 V AC 50/60 Hz, 3-pole, Size S00 screw terminals electrical and mechanical interlock 3 NO integrated","During Storage":"-55 ... +80 °C","Of Magnet Coil":"Screw-type terminals","at AC-3 maximum":"1 000 1/h","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"Contactor assembly for star-delta (wye-delta) start","Of Contactor Typical":"10 000 000","at 400 V rated value":"5.5 kW","at 50 Hz rated value":"230 V","at 500 V rated value":"7.2 kW","at 60 Hz rated value":"230 V","at 690 V rated value":"9.2 kW","Instantaneous Contact":"3","For Main Current Circuit":"screw-type terminals","1 Of The Supplied Contactor":"3RT2015-1AP01","2 Of The Supplied Contactor":"3RT2015-1AP01","3 Of The Supplied Contactor":"3RT2015-1AP01","at AC-3 rated value maximum":"690 V","Substance Prohibitance (Date)":"10/01/2009","of the supplied RS assembly kit":"3RA2913-2BB1","For Auxiliary And Control Circuit":"screw-type terminals","Product Extension Auxiliary Switch":"No","Product Function Bus Communication":"No","With Type Of Assignment 2 Required":"gG NH 3NA, DIAZED 5SB, NEOZED 5SE: 20 A","At Contactor For Auxiliary Contacts":"Screw-type terminals","With Type Of Coordination 1 Required":"gG NH 3NA, DIAZED 5SB, NEOZED 5SE: 35 A","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"< 1 error per 100 million operating cycles","with low demand rate according to SN 31920":"40 %","protocol is supported AS-Interface protocol":"No","with high demand rate according to SN 31920":"75 %","Type Of Voltage Of The Control Supply Voltage":"AC","contact rating of auxiliary contacts according to UL":"A600 / Q600","Of The Supplied Function Module For Wye-Delta Circuits":"3RA2816-0EW20","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","product function control circuit interface with IO link":"No","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gG: 10 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/47af7acaa9edecaa155fe090bfc77b8a.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=352003&mlfb=3RA2415-8XF31-1AP0"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2415-8XF31-1AP0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2415-8XF31-1AP0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}