{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA2813-2AW10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA2813-2AW10","canonicalUrl":"https://aoctrl.com/siemens/3RA2813-2AW10","factsUrl":"https://aoctrl.com/api/mcp/products/3RA2813-2AW10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA2813-2AW10 timer relay, ON-delay function, adjustable time 0.05-100 s, 3 A switching current, 24-240 V AC/DC control supply, clip-on DIN rail mounting.","salesMarkdown":"## 74x45x38 mm DIN-rail clip-on — panel fill factor The 3RA2813-2AW10: The 74 mm depth, 45 mm width, and 38 mm height footprint clips onto standard DIN rail — no screws, no bracket. Mounting position is any orientation, same as a contactor, which simplifies layout in a crowded panel. Wire range accepts 20-14 AWG solid or stranded, so it ties into existing control wiring without a terminal adapter. ## ON-delay only — adjustable 0.05-100 s, universal control supply This is a single-function ON-delay timer relay — no OFF-delay, no pulse-shaping, no star-delta timing. The delay is adjustable from 0.05 to 100 seconds via a front-panel potentiometer (or screwdriver slot), so you dial in the interval on-site without swapping modules. Control supply voltage is AC/DC 24-240 V at 50/60 Hz — one part covers both line and low-voltage DC control schemes, reducing panel stock complexity. Recovery time is 150 ms — the minimum off-time before the timer can retrigger. If the application cycles faster than that, the output may not reset. ## Industrial temperature range and pollution tolerance Rated for operation from -25 to +60 °C, with storage and transport limits of -40 to +85 °C — fits unconditioned cabinets and outdoor-adjacent enclosures. Basic insulation with pollution degree 3 means it's designed for industrial environments where conductive dust or condensation may be present — no need for a sealed enclosure in a typical panel.","metaTitle":"Siemens 3RA2813-2AW10 SIRIUS Timer Relay, ON-Delay","metaDescription":"Siemens 3RA2813-2AW10 SIRIUS timer relay, ON-delay only, adjustable 0.05-100 s, 3 A max switching, 24-240 V AC/DC coil. Active production, clip-on DIN rail.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Starters"],"specifications":{"Depth":"74 mm","Solid":"20 ... 14","Width":"45 mm","at DC":"24 ... 240 V","title":"3RA2813-2AW10","Height":"38 mm","Maximum":"3 A","Upwards":"0 mm","at 24 V":"1 A","Forwards":"0 mm","ON-delay":"Yes","Stranded":"20 ... 14","at 125 V":"0.2 A","at 250 V":"0.1 A","at 50 Hz":"24 ... 240 V","at 60 Hz":"24 ... 240 V","Backwards":"0 mm","Downwards":"0 mm","OFF delay":"No","At The Side":"0 mm","description":"solid-state time-delayed auxiliary switch, ON-delay, relay: 1 CO, time range 0.05-100 s, 24-240 V AC/DC, 50/60 Hz, varistor for attenuation of the contactor coils integrated, spring-loaded terminal, can be snapped on at the front on contactors 3RT2 and auxiliary contactors 3RH2","Non-Volatile":"No","Initial Value":"0.85","Pulse Delayed":"No","Pulse-Shaping":"No","Recovery Time":"150 ms","During Storage":"-40 ... +85 °C","Adjustable Time":"0.05 ... 100 s","Type Of Voltage":"AC/DC","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","During Transport":"-40 ... +85 °C","Fastening Method":"clip-on","Full-Scale Value":"1.1","Delayed Switching":"1","Mounting Position":"any (like contactor)","additive ON-delay":"No","ON-delay/OFF-delay":"No","Product Brand Name":"SIRIUS","Star-Delta Circuit":"No","Type Of Insulation":"Basic insulation","Degree Of Pollution":"3","Product Designation":"Solid-state time-delay auxiliary switch","Passing Make Contact":"No","for AWG cables solid":"2x (20 ... 14)","Passing Break Contact":"No","Power Supply Influence":"±1 %","OFF delay/instantaneous":"No","for AWG cables stranded":"2x (20 ... 14)","Relative Repeat Accuracy":"1 %","Pulse Delayed/Instantaneous":"No","Pulse-Shaping/Instantaneous":"No","Substance Prohibitance (Date)":"10/01/2009","Design Of The Surge Suppressor":"with varistor","Material Of Switching Contacts":"AgNi","ON-delay/instantaneous contact":"No","Test Voltage For Isolation Test":"1.5 kV","additive ON-delay/instantaneous":"No","ON-delay/OFF-delay/instantaneous":"No","Variably Clocked With Pulse Start":"No","Control Supply Voltage Frequency 1":"50 ... 60 Hz","Relative Humidity During Operation":"0 ... 95 %","Star-Delta Circuit With Delay Time":"No","Passing Break Contact/Instantaneous":"No","Product Function Star-Delta Circuit":"No","Test Voltage For Surge Voltage Test":"4 800 V","protection class IP of the terminal":"IP20","Surge Voltage Resistance Rated Value":"4 kV","Variably Clocked With Interval Start":"No","with contactor 3R.2 of frame size S0":"100 000","with contactor 3R.2 of frame size S2":"100 000","with contactor 3R.2 of frame size S3":"100 000","Constant Clock Cycle With Pulse Start":"No","EMC immunity according to IEC 61812-1":"Environment A (industrial area)","with contactor 3R.2 of frame size S00":"100 000","Flashing Symmetrically With Pulse Start":"No","Product Component Semi-Conductor Output":"No","due to burst according to IEC 61000-4-4":"2 kV network connection / 1 kV control connection","reference code according to IEC 81346-2":"K","Constant Clock Cycle With Interval Start":"No","Finely Stranded With Core End Processing":"0.5 ... 2.5 mm²","Flashing Asymmetrically With Pulse Start":"No","Influence Of The Surrounding Temperature":"±1 %","Product Extension Optional Remote Control":"No","Product Extension Required Remote Control":"No","Flashing Symmetrically With Interval Start":"No","Passing Make Contact/Instantaneous Contact":"No","Design Of The Control Terminal Non-Floating":"Yes","Finely Stranded Without Core End Processing":"0.25 ... 1.5 mm²","Flashing Asymmetrically With Interval Start":"No","shock resistance according to IEC 60068-2-27":"15g / 11 ms","Retriggerable With Deactivated Control Signal":"No","Type Of Voltage Of The Control Supply Voltage":"AC/DC","operating frequency with 3RT2 contactor maximum":"2 500 1/h","vibration resistance according to IEC 60068-2-6":"10 ... 59 Hz: 0.35 mm, 60 ... 150 Hz: 2g","Retrotriggerable With Switched-On Control Signal":"No","Mechanical Service Life (Operating Cycles) Typical":"10 000 000","Size Of Contactor Can Be Combined Company-Specific":"S00, S0, S2, S3","electrostatic discharge according to IEC 61000-4-2":"8 kV","operational current of auxiliary contacts at DC-13":"1 ... 0.1","contact rating of auxiliary contacts according to UL":"B300 / R300","At The Relay Outputs Switchover Delayed/Without Delay":"No","Flashing Symmetrically With Pulse Start/Instantaneous":"No","Relative Setting Accuracy Relating To Full-Scale Value":"15 %","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Flashing Symmetrically With Interval Start/Instantaneous":"No","Type Of Electrical Connection For Auxiliary And Control Circuit":"spring-loaded terminals","Product Component Removable Terminal For Auxiliary And Control Circuit":"Yes","Retrotriggerable With Deactivated Control Signal/Instantaneous Contact":"No","Retrotriggerable With Switched-On Control Signal/Instantaneous Contact":"No","Design Of The Fuse Link For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 4 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a52e0b188d197efe01e98a976a2f9ee8.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=275347&mlfb=3RA2813-2AW10"},"ai":{"faq":[{"question":"What is the 3RA2813-2AW10's adjustable time range?","answer":"The ON-delay is adjustable from 0.05 to 100 seconds, set via the front-panel adjuster. This covers most sequence-start and anti-short-cycle timing needs in motor control panels."},{"question":"What control voltage does the 3RA2813-2AW10 accept?","answer":"It accepts AC or DC from 24 to 240 V, at 50 or 60 Hz. One part works across 24 V DC PLC outputs, 120 V AC control transformers, and 240 V AC line supplies."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA2813-2AW10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA2813-2AW10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}