{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA6250-1BB34","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA6250-1BB34","canonicalUrl":"https://aoctrl.com/siemens/3RA6250-1BB34","factsUrl":"https://aoctrl.com/api/mcp/products/3RA6250-1BB34","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA6250-1BB34 compact reversing starter, 53 kA at 400 V, adjustable Trip Class 10/20, 24 V AC/DC control, screw terminals, DIN rail mount.","salesMarkdown":"## Reversing starter with 53 kA SCCR — what that means for panel coordination The 3RA6250-1BB34 is a SIRIUS compact reversing starter rated for 53 kA short-circuit breaking capacity at 400 V. That figure governs selectivity with the upstream protective device — a 53 kA SCCR at the motor branch means the starter clears a fault without forcing the feeder breaker to trip, keeping the rest of the panel online. It carries an adjustable Trip Class of 10 and 20, so the same unit handles both fast-protection (Class 10) for submersible pumps or compressors and slower coordination (Class 20) for high-inertia loads like fans or centrifuges — set it at commissioning, no hardware swap. ## DIN rail footprint and wire terminations The reversing starter measures 90 mm wide by 170 mm high by 165 mm deep — that's a three-wide module on standard 35 mm DIN rail. Mounting is screw-and-snap-on to the DIN rail; the unit can be oriented vertically or horizontally, and the enclosure is rated for pollution degree 3 — standard for industrial control panels with conductive dust or humidity. ## Control voltage and environmental limits Three onboard LEDs give status indication without a separate display. Operating temperature range is -20 to +60 °C; storage and transport range is -55 to +80 °C. Vibration resistance is specified at 20 m/s² from 5.8 to 500 Hz, and shock resistance at 60 m/s² (6 g) for 10 ms — suitable for machine-mounted applications with moderate mechanical stress.","metaTitle":"Siemens 3RA6250-1BB34 SIRIUS Reversing Starter","metaDescription":"Siemens 3RA6250-1BB34 SIRIUS compact reversing starter, 53 kA SCCR at 400 V, adjustable Class 10/20, 24 V AC/DC control. Active production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Starters"],"specifications":{"Depth":"165 mm","Solid":"0.5 ... 4 mm², 2x (0.5 ... 2.5 mm²)","Width":"90 mm","at DC":"24 ... 24 V","title":"3RA6250-1BB34","Height":"170 mm","at 400 V":"53 kA","at 50 Hz":"24 ... 24 V","at 60 Hz":"24 V","Trip Class":"CLASS 10 and 20 adjustable","Recommended":"vertical, on horizontal standard DIN rail","description":"SIRIUS Compact load feeder Reversing starter 690 V 24 V AC/DC 50...60 Hz 0.32...1.25 A IP20 Connection main circuit: Screw terminal Connection control circuit: plug-in, without terminals","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","at AC maximum":"2.8 W","at DC maximum":"2.9 W","During Storage":"-55 ... +80 °C","number of LEDs":"3","Type Of Voltage":"AC/DC","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-55 ... +80 °C","Fastening Method":"screw and snap-on mounting","IO-Link protocol":"No","Shock Resistance":"a=60 m/s2 (6g) with 10 ms per 3 shocks in all axes","Mounting Position":"any","at DC rated value":"24 V","Product Brand Name":"SIRIUS","Type Of Assignment":"continous operation according to IEC 60947-6-2","Degree Of Pollution":"3","Product Designation":"compact starter","Vibration Resistance":"f= 4 ... 5.8 Hz, d= 15 mm; f= 5.8 ... 500 Hz, a= 20 m/s²; 10 cycles","at 400 V rated value":"370 W","at 480 V rated value":"1.25 A","at 50 Hz rated value":"24 V","at 500 V rated value":"3 kA","at 60 Hz rated value":"24 V","at 600 V rated value":"1.25 A","at 690 V rated value":"3 kA","AS-Interface protocol":"No","Design Of The Product":"reversing starter","For Main Current Circuit":"screw-type terminals","at 460/480 V rated value":"0.5 hp","at 575/600 V rated value":"0.5 hp","at AC at 400 V rated value":"1.25 A","NO-Load Switching Frequency":"3 600 1/h","Of The Main Contacts Typical":"10 000 000","at AC in hot operating state":"0.1 W","at AC-3 at 400 V rated value":"0.37 kW","Of Auxiliary Contacts Typical":"10 000 000","Substance Prohibitance (Date)":"05/01/2012","Insulation Voltage Rated Value":"690 V","at DC-13 at 6 A at 24 V typical":"30 000","at AC-15 at 6 A at 230 V typical":"200 000","degree of protection NEMA rating":"other","For Auxiliary And Control Circuit":"plug-in without terminals","Of The Signaling Contacts Typical":"10 000 000","Between Main And Auxiliary Circuit":"400 V","Design Of Short-Circuit Protection":"electromagnetic","Product Extension Auxiliary Switch":"Yes","Product Function Bus Communication":"No","Relative Humidity During Operation":"10 ... 90 %","Without Load Current Share Typical":"2.9 W","Surge Voltage Resistance Rated Value":"6 000 V","at AWG cables for auxiliary contacts":"2x (20 ... 14)","Between Control And Auxiliary Circuit":"300 V","at AC in hot operating state per pole":"0.03 W","Between Auxiliary And Auxiliary Circuit":"250 V","due to burst according to IEC 61000-4-4":"4 kV main contacts, 2 kV auxiliary contacts","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"0.5 ... 2.5 mm², 2x (0.5 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Formula For Making Capacity Limit Current":"38.4 x Ie","Product Function Short Circuit Protection":"Yes","Supply voltage required Auxiliary voltage":"No","with low demand rate according to SN 31920":"40 %","Formula For Limit Current Breaking Capacity":"32 x Ie","at AC-41 according to IEC 60947-6-2 maximum":"750 1/h","at AC-43 according to IEC 60947-6-2 maximum":"250 1/h","with high demand rate according to SN 31920":"50 %","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"2","operating voltage at AC-3 rated value maximum":"690 V","electrostatic discharge according to IEC 61000-4-2":"8 kV","contact rating of auxiliary contacts according to UL":"contacts 21-22, 13-14, 43-44 Q600 / A600, contacts 77-78 R300 / B300, contacts 95-96-98 R300 / D300","Product Component Removable Terminal For Main Circuit":"Yes","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","product function control circuit interface with IO link":"No","conducted HF interference emissions according to CISPR11":"150 kHz ... 30 MHz Class A","field-bound HF interference emission according to CISPR11":"30 ... 1000 MHz Class A","operational current of auxiliary contacts at AC-12 maximum":"10 A","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Product Function Control Circuit Interface To Parallel Wiring":"Yes","Product Component Removable Terminal For Auxiliary And Control Circuit":"Yes","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.32 ... 1.25 A","number of NO contacts of instantaneous short-circuit trip unit for signaling contact":"1","For Short-Circuit Protection Of The Signaling Switch Of The Overload Release Required":"4A gL/gG/400V","number of CO contacts of the current-dependent overload release for signaling contact":"1","For Short-Circuit Protection Of The Signaling Switch Of The Short-Circuit Release Required":"6A gL/gG/400V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3684b9aff838e7f15e402db67cb2f733.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=400237&mlfb=3RA6250-1BB34"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA6250-1BB34","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA6250-1BB34 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}