{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RA6250-2BB32","brand":"Siemens","brandSlug":"siemens","productSlug":"3RA6250-2BB32","canonicalUrl":"https://aoctrl.com/siemens/3RA6250-2BB32","factsUrl":"https://aoctrl.com/api/mcp/products/3RA6250-2BB32","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RA6250-2BB32 compact reversing starter, 370 W at 400 V, 53 kA breaking capacity, 24 V AC/DC control supply, adjustable trip class 10 and 20, spring-loaded terminals, DIN rail mount.","salesMarkdown":"The 3RA6250-2BB32: The reversing function is built into a single 90 mm wide housing, so a forward-reverse motor pair fits in one DIN-rail footprint rather than two separate contactors with a mechanical interlock. The unit is rated for continuous operation per IEC 60947-6-2, meaning it handles sustained motor loads without derating. ## Adjustable overload protection and spring-clamp wiring Trip class is field-selectable between CLASS 10 and CLASS 20 via a dial on the front. CLASS 10 protects motors with short acceleration times (pumps, fans), while CLASS 20 allows longer start-up for high-inertia loads like conveyors or crushers — both settings are in one device, no module swap needed. Spring-clamp termination eliminates the need for torque-checking screw terminals and resists loosening under vibration — relevant for the shock resistance rating of 60 m/s² (6g) over 10 ms per axis. Control voltage is 24 V AC/DC, with a maximum power draw of 2.8 W at AC and 2.9 W at DC. The 24 V coil is common across modern PLC-based panels, and the low power consumption keeps the control transformer sizing tight. ## DIN-rail envelope and environmental limits Dimensions are 191 mm high, 90 mm wide, 165 mm deep — a standard SIRIUS form factor that fits alongside other SIRIUS devices on a horizontal standard DIN rail. Mounting position is any orientation, with screw and snap-on fastening for the rail. Operating temperature range is -20 to +60 °C, storage and transport range -55 to +80 °C. Pollution degree 3 means it tolerates conductive dust and humidity typical of industrial enclosures without conformal coating. Vibration resistance is specified at 4 to 5.8 Hz with 15 mm amplitude and 5.8 to 500 Hz at 20 m/s² for 10 cycles — this covers most rotating machinery environments up to medium-impact applications. No official successor or cross-reference has been published by Siemens for this order code. The SIRIUS series is mature and widely stocked, but each variant's control voltage and trip class are specific — confirm the BOM line before committing.","metaTitle":"Siemens 3RA6250-2BB32 SIRIUS Reversing Starter, 370 W, 53 kA","metaDescription":"Siemens 3RA6250-2BB32 SIRIUS compact reversing starter, 370 W at 400 V, 53 kA breaking capacity, 24 V AC/DC coil, adjustable trip class 10/20.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Starters"],"specifications":{"Depth":"165 mm","Solid":"2x (0.25 ... 1.5 mm²)","Width":"90 mm","at DC":"24 ... 24 V","title":"3RA6250-2BB32","Height":"191 mm","at 400 V":"53 kA","at 50 Hz":"24 ... 24 V","at 60 Hz":"24 V","Trip Class":"CLASS 10 and 20 adjustable","Recommended":"vertical, on horizontal standard DIN rail","description":"SIRIUS Compact load feeder Reversing starter 690 V 24 V AC/DC 50...60 Hz 0.32...1.25 A IP20 Connection main circuit: Spring-type terminal Connection control circuit: Spring-type terminal","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","at AC maximum":"2.8 W","at DC maximum":"2.9 W","During Storage":"-55 ... +80 °C","number of LEDs":"3","Type Of Voltage":"AC/DC","lifecycle_stage":"current","During Operation":"-20 ... +60 °C","During Transport":"-55 ... +80 °C","Fastening Method":"screw and snap-on mounting","IO-Link protocol":"No","Shock Resistance":"a=60 m/s2 (6g) with 10 ms per 3 shocks in all axes","Mounting Position":"any","at DC rated value":"24 V","Product Brand Name":"SIRIUS","Type Of Assignment":"continous operation according to IEC 60947-6-2","Degree Of Pollution":"3","Product Designation":"compact starter","Vibration Resistance":"f= 4 ... 5.8 Hz, d= 15 mm; f= 5.8 ... 500 Hz, a= 20 m/s²; 10 cycles","at 400 V rated value":"370 W","at 480 V rated value":"1.25 A","at 50 Hz rated value":"24 V","at 500 V rated value":"3 kA","at 60 Hz rated value":"24 V","at 600 V rated value":"1.25 A","at 690 V rated value":"3 kA","AS-Interface protocol":"No","Design Of The Product":"reversing starter","For Main Current Circuit":"spring-loaded terminals","at 460/480 V rated value":"0.5 hp","at 575/600 V rated value":"0.5 hp","at AC at 400 V rated value":"1.25 A","NO-Load Switching Frequency":"3 600 1/h","Of The Main Contacts Typical":"10 000 000","at AC in hot operating state":"0.1 W","at AC-3 at 400 V rated value":"0.37 kW","Of Auxiliary Contacts Typical":"10 000 000","Substance Prohibitance (Date)":"05/01/2012","Insulation Voltage Rated Value":"690 V","at DC-13 at 6 A at 24 V typical":"30 000","at AC-15 at 6 A at 230 V typical":"200 000","degree of protection NEMA rating":"other","For Auxiliary And Control Circuit":"spring-loaded terminals","Of The Signaling Contacts Typical":"10 000 000","Between Main And Auxiliary Circuit":"400 V","Design Of Short-Circuit Protection":"electromagnetic","Product Extension Auxiliary Switch":"Yes","Product Function Bus Communication":"No","Relative Humidity During Operation":"10 ... 90 %","Without Load Current Share Typical":"2.9 W","Surge Voltage Resistance Rated Value":"6 000 V","at AWG cables for auxiliary contacts":"2x (24 ... 16)","Between Control And Auxiliary Circuit":"300 V","at AC in hot operating state per pole":"0.03 W","Between Auxiliary And Auxiliary Circuit":"250 V","due to burst according to IEC 61000-4-4":"4 kV main contacts, 2 kV auxiliary contacts","reference code according to IEC 81346-2":"Q","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Formula For Making Capacity Limit Current":"38.4 x Ie","Product Function Short Circuit Protection":"Yes","Supply voltage required Auxiliary voltage":"No","with low demand rate according to SN 31920":"40 %","Finely Stranded Without Core End Processing":"2x (0.25 ... 1.5 mm²)","Formula For Limit Current Breaking Capacity":"32 x Ie","at AC-41 according to IEC 60947-6-2 maximum":"750 1/h","at AC-43 according to IEC 60947-6-2 maximum":"250 1/h","with high demand rate according to SN 31920":"50 %","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"2","operating voltage at AC-3 rated value maximum":"690 V","electrostatic discharge according to IEC 61000-4-2":"8 kV","contact rating of auxiliary contacts according to UL":"contacts 21-22, 13-14, 43-44 Q600 / A600, contacts 77-78 R300 / B300, contacts 95-96-98 R300 / D300","Product Component Removable Terminal For Main Circuit":"Yes","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","product function control circuit interface with IO link":"No","conducted HF interference emissions according to CISPR11":"150 kHz ... 30 MHz Class A","field-bound HF interference emission according to CISPR11":"30 ... 1000 MHz Class A","operational current of auxiliary contacts at AC-12 maximum":"10 A","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Product Function Control Circuit Interface To Parallel Wiring":"Yes","Product Component Removable Terminal For Auxiliary And Control Circuit":"Yes","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.32 ... 1.25 A","number of NO contacts of instantaneous short-circuit trip unit for signaling contact":"1","For Short-Circuit Protection Of The Signaling Switch Of The Overload Release Required":"4A gL/gG/400V","number of CO contacts of the current-dependent overload release for signaling contact":"1","For Short-Circuit Protection Of The Signaling Switch Of The Short-Circuit Release Required":"6A gL/gG/400V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/097ffed30f5a0c6e9d0bc0581c21d935.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=533316&mlfb=3RA6250-2BB32"},"ai":{"faq":[{"question":"What is the breaking capacity of 3RA6250-2BB32 at 400 V?","answer":"53 kA at 400 V."},{"question":"What compliance documentation does Siemens provide for 3RA6250-2BB32?","answer":"The product carries IEC 60947-6-2 certification for continuous operation as a reversing starter. Pollution degree 3 per IEC 60664 is specified. RoHS and REACH declarations are standard for Siemens SIRIUS products, though the specific document numbers are not listed in this record."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RA6250-2BB32","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RA6250-2BB32 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}