{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RB2056-1FF2","brand":"Siemens","brandSlug":"siemens","productSlug":"3RB2056-1FF2","canonicalUrl":"https://aoctrl.com/siemens/3RB2056-1FF2","factsUrl":"https://aoctrl.com/api/mcp/products/3RB2056-1FF2","rawCanonicalId":null},"summary":{"shortDescription":"Overload relay 50...200 A for motor protection Size S6, Class 10E Contactor mounting/stand-alone installation Main circuit: busbar connection Auxiliary circuit: Spring-type terminal Manual-Automatic-Reset","salesMarkdown":null,"metaTitle":"3RB2056-1FF2 - Siemens","metaDescription":"Overload relay 50...200 A for motor protection Size S6, Class 10E Contactor mounting/stand-alone installation Main circuit: busbar connection Auxiliary circuit: Spring-type terminal Manual-Automatic-Reset","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Overload Relays"],"specifications":{"Note":"for message \"tripped\"","Depth":"155 mm","Solid":"2x (0.25 ... 1.5 mm²)","Width":"120 mm","Height":"119 mm","at 24 V":"2 A","at 60 V":"0.55 A","at 110 V":"0.3 A","at 120 V":"4 A","at 125 V":"0.3 A","at 220 V":"0.11 A","at 230 V":"3 A","Trip Class":"CLASS 10E","Rated Value":"1 000 V","During Storage":"-40 ... +80 °C","Thermal Current":"200 A","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","During Transport":"-40 ... +80 °C","Fastening Method":"Contactor mounting/stand-alone installation","Shock Resistance":"15g / 11 ms","For Main Contacts":"M8","Mounting Position":"any","Solid Or Stranded":"2x (0,25 ... 1,5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"solid-state overload relay","Vibration Resistance":"1-6 Hz, 15 mm; 6-500 Hz, 20 m/s²; 10 cycles","at 480 V rated value":"200 A","at 600 V rated value":"200 A","Size Of Overload Relay":"S6","For Main Current Circuit":"busbar connection","Temperature Compensation":"-25 ... +60 °C","according to IEC 60068-2-27":"15g / 11 ms","at AC-3e rated value maximum":"1 000 V","Substance Prohibitance (Date)":"07/01/2006","Design Of The Auxiliary Switch":"integrated","Design Of The Overload Release":"electronic","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"200 A","for AC motors at 500 V at 50 Hz":"30 ... 132 kW","for AC motors at 690 V at 50 Hz":"55 ... 160 kW","For Auxiliary And Control Circuit":"spring-loaded terminals","Between Main And Auxiliary Circuit":"690 V","Relative Humidity During Operation":"10 ... 95 %","With Type Of Assignment 2 Required":"gG: 315 A","Display Version For Switching Status":"Slide switch","Surge Voltage Resistance Rated Value":"8 kV","With Type Of Coordination 1 Required":"gG: 355 A, Class L: 601 A","at AWG cables for auxiliary contacts":"2x (24 ... 16)","for 3-phase motors at 400 V at 50 Hz":"30 ... 90 kW","Between Auxiliary And Auxiliary Circuit":"300 V","due to burst according to IEC 61000-4-4":"2 kV (power ports), 1 kV (signal ports) corresponds to degree of severity 3","reference code according to IEC 81346-2":"F","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Finely Stranded Without Core End Processing":"2x (0.25 ... 1.5 mm²)","For Main Contacts With Screw-Type Terminals":"10 ... 12 N·m","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","operational current at AC-3e at 400 V rated value":"200 A","Size Of Contactor Can Be Combined Company-Specific":"S6","electrostatic discharge according to IEC 61000-4-2":"6 kV contact discharge / 8 kV air discharge","Type Of Voltage Supply Via Input/Output Link Master":"No","contact rating of auxiliary contacts according to UL":"B600 / R300","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gG: 6 A","insulation voltage with degree of pollution 3 at AC rated value":"1 000 V","Product Component Removable Terminal For Auxiliary And Control Circuit":"Yes","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"50 ... 200 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=465940&mlfb=3RB2056-1FF2","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RB2056-1FF2/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RB2056-1FF2","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RB2056-1FF2 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}