{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RB3016-1NE0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RB3016-1NE0","canonicalUrl":"https://aoctrl.com/siemens/3RB3016-1NE0","factsUrl":"https://aoctrl.com/api/mcp/products/3RB3016-1NE0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RB3016-1NE0 solid-state overload relay, Size S00, CLASS 10E, 1.25 A thermal current, 690 V rated value, spring-loaded terminals, 45 x 72 x 90 mm.","salesMarkdown":"## Active production — CLASS 10E solid-state trip for motor protection The 3RB3016-1NE0: Rated thermal current is 1.25 A at 690 V (AC-3e), suitable for small motor loads up to about 0.37 kW at 400 V. The electronic overload release provides temperature-compensated tripping across the full -25 to +60 °C operating range, so the protection curve stays accurate regardless of ambient heat near the starter. ## Panel integration — spring-loaded terminals, contactor-mount, any position Mounts directly onto a contactor via the fastening method, eliminating separate DIN-rail space. Accepts 2× (0.25 to 1.5 mm²) solid or stranded wire through spring-loaded terminals — no screw torque required, just push the stripped conductor in. The Pozidriv PZ 2 screwdriver tip with 5–6 mm shaft diameter is specified for the release button and auxiliary terminal access. Dimensions are 45 mm wide, 72 mm high, 90 mm deep — the S00 footprint matches the Siemens 3RT2 contactor series. Mounting position is any orientation, so panel layout is flexible. Vibration resistance is 1–6 Hz at 15 mm amplitude and 6–500 Hz at 20 m/s² for 10 cycles; shock resistance is 15 g for 11 ms per IEC 60068-2-27. ## Auxiliary contact ratings and signalling An integrated auxiliary switch provides the tripped signal on terminals 97/98. Contact ratings vary by voltage: 2 A at 24 V DC, 4 A at 120 V AC, 3 A at 230 V AC, and 0.55 A at 60 V DC. The note \"for message 'tripped'\" means this contact closes when the relay has operated — use it to trigger a PLC input, alarm lamp, or safety chain. Power dissipation per pole is 0.03 W, negligible for panel thermal budgeting. The auxiliary circuit draws minimal current from the control supply, allowing direct connection to a 24 V DC PLC input module without an intermediate relay. ## Environmental tolerance and compliance Operating temperature range is -25 to +60 °C with full temperature compensation; storage and transport range is -40 to +80 °C. Substance prohibitance date is 10/01/2009, indicating RoHS compliance from that date forward. The operating frequency is 50/60 Hz, covering standard industrial mains.","metaTitle":"Siemens 3RB3016-1NE0 SIRIUS solid-state overload relay","metaDescription":"Siemens SIRIUS 3RB3016-1NE0 solid-state overload relay, Size S00, CLASS 10E trip, 1.25 A rated current, 690 V max, spring-loaded terminals.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Overload Relays"],"specifications":{"Note":"for message \"tripped\"","Depth":"90 mm","Solid":"2x (0.25 ... 1.5 mm²)","Width":"45 mm","title":"3RB3016-1NE0","Height":"72 mm","at 24 V":"2 A","at 60 V":"0.55 A","Per Pole":"0.03 W","at 110 V":"0.3 A","at 120 V":"4 A","at 125 V":"0.3 A","at 220 V":"0.11 A","at 230 V":"3 A","Trip Class":"CLASS 10E","Rated Value":"690 V","description":"Overload relay 0.32...1.25 A Electronic For motor protection Size S00, Class 10E Contactor mounting Main circuit: Spring-type terminal Auxiliary circuit: Spring-type terminal Manual-Automatic-Reset","During Storage":"-40 ... +80 °C","Thermal Current":"1.25 A","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","During Transport":"-40 ... +80 °C","Fastening Method":"Contactor mounting","Shock Resistance":"15g / 11 ms","Mounting Position":"any","Solid Or Stranded":"2x (0,25 ... 1,5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"solid-state overload relay","Vibration Resistance":"1-6 Hz, 15 mm; 6-500 Hz, 20 m/s²; 10 cycles","at 480 V rated value":"1.25 A","at 600 V rated value":"1.25 A","Size Of Overload Relay":"S00","For Main Current Circuit":"spring-loaded terminals","Temperature Compensation":"-25 ... +60 °C","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Screwdriver Tip":"Pozidriv PZ 2","according to IEC 60068-2-27":"15g / 11 ms; Signaling contact 97 / 98 in position \"Tripped\": 9g / 11 ms","at AC-3e rated value maximum":"690 V","Substance Prohibitance (Date)":"10/01/2009","Design Of The Auxiliary Switch":"integrated","Design Of The Overload Release":"electronic","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"1.25 A","for AC motors at 500 V at 50 Hz":"0.12 ... 0.55 kW","for AC motors at 690 V at 50 Hz":"0.18 ... 0.75 kW","For Auxiliary And Control Circuit":"spring-loaded terminals","Between Main And Auxiliary Circuit":"690 V","Relative Humidity During Operation":"10 ... 95 %","With Type Of Assignment 2 Required":"gG: 6 A","Display Version For Switching Status":"Slide switch","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"gG: 35 A, RK5: 6 A","for 3-phase motors at 400 V at 50 Hz":"0.12 ... 0.37 kW","for AWG cables for auxiliary contacts":"1x (24 ... 16), 2x (24 ... 16)","Between Auxiliary And Auxiliary Circuit":"300 V","due to burst according to IEC 61000-4-4":"2 kV (power ports), 1 kV (signal ports) corresponds to degree of severity 3","reference code according to IEC 81346-2":"F","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Finely Stranded Without Core End Processing":"2x (0.25 ... 1.5 mm²)","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","operational current at AC-3e at 400 V rated value":"1.25 A","Size Of Contactor Can Be Combined Company-Specific":"S00","electrostatic discharge according to IEC 61000-4-2":"6 kV contact discharge / 8 kV air discharge","Type Of Voltage Supply Via Input/Output Link Master":"No","contact rating of auxiliary contacts according to UL":"B600 / R300","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gG: 6 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Product Component Removable Terminal For Auxiliary And Control Circuit":"Yes","power loss [W] for rated value of the current at AC in hot operating state":"0.1 W","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.32 ... 1.25 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$48.26","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c86ab05d851189fd853fa12eaafc7dca.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=226882&mlfb=3RB3016-1NE0"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RB3016-1NE0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RB3016-1NE0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}