{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RB3016-1PB0-ZW96","brand":"Siemens","brandSlug":"siemens","productSlug":"3RB3016-1PB0-ZW96","canonicalUrl":"https://aoctrl.com/siemens/3RB3016-1PB0-ZW96","factsUrl":"https://aoctrl.com/api/mcp/products/3RB3016-1PB0-ZW96","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RB3016-1PB0-ZW96 solid-state overload relay, CLASS 10E, 4 A thermal current, 690 V rated value, S00 frame, contactor mounting, screw-type terminals.","salesMarkdown":"## S00 frame solid-state overload relay, contactor-mounted The Siemens 3RB3016-1PB0-ZW96 is a SIRIUS solid-state overload relay in the S00 frame size, designed for direct mounting onto a contactor — no separate DIN-rail footprint needed. Rated thermal current is 4 A continuous, with a maximum operating voltage of 690 V (AC-3e rated value). The trip class is CLASS 10E, meaning it will trip within 10 seconds at 7.2× the set current — fast enough to protect standard squirrel-cage motors during a locked-rotor event. ## Auxiliary contact ratings and wiring The integrated auxiliary switch (signaling contact 97/98) is rated for switching at multiple control voltages: 2 A at 24 V, 4 A at 120 V, 3 A at 230 V, and 0.55 A at 60 V — covering most PLC input and relay coil circuits in a panel. Terminals accept 1x (0.5 to 4 mm²) or 2x (0.5 to 2.5 mm²) solid or stranded wire, with screw-type connections requiring a Pozidriv PZ2 tip. The relay measures 45 mm wide × 79 mm high × 73 mm deep — fits the S00 contactor footprint without crowding adjacent devices. ## Environmental and mechanical endurance Operating temperature range is -25 to +60 °C with temperature compensation active across that band — no derating needed for ambient heat up to 60 °C. Storage and transport range extends from -40 to +80 °C. Rated shock resistance is 15g / 11 ms per IEC 60068-2-27 (signaling contact in tripped position: 9g / 11 ms). Vibration resistance covers 1–6 Hz at 15 mm amplitude and 6–500 Hz at 20 m/s² for 10 cycles — suitable for machine-mounted applications with moderate vibration. ## Lifecycle and sourcing Substance prohibitance date is 10/01/2009, indicating RoHS compliance per the manufacturer's declaration.","metaTitle":"Siemens 3RB3016-1PB0-ZW96 SIRIUS solid-state overload relay","metaDescription":"Siemens 3RB3016-1PB0-ZW96 SIRIUS solid-state overload relay, CLASS 10E trip, 4 A thermal current, 690 V max. S00 frame, contactor-mount.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Overload Relays"],"specifications":{"Note":"for message \"tripped\"","Depth":"73 mm","Solid":"1x (0.5 ... 4 mm²), 2x (0.5 ... 2.5 mm²)","Width":"45 mm","title":"3RB3016-1PB0-ZW96","Height":"79 mm","at 24 V":"2 A","at 60 V":"0.55 A","Per Pole":"0.03 W","at 110 V":"0.3 A","at 120 V":"4 A","at 125 V":"0.3 A","at 220 V":"0.11 A","at 230 V":"3 A","Trip Class":"CLASS 10E","Rated Value":"690 V","description":"Overload relay 1...4 A Electronic For motor protection Size S00, Class 10E Contactor mounting Main circuit: screw terminal Auxiliary circuit: screw terminal Manual-Automatic-Reset Multi-unit packaging Pack = 30 units","During Storage":"-40 ... +80 °C","Thermal Current":"4 A","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","During Transport":"-40 ... +80 °C","Fastening Method":"Contactor mounting","Shock Resistance":"15g / 11 ms","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"1x (0,5 ... 4 mm²), 2x (0,5 ... 2,5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"solid-state overload relay","Vibration Resistance":"1-6 Hz, 15 mm; 6-500 Hz, 20 m/s²; 10 cycles","at 480 V rated value":"4 A","at 600 V rated value":"4 A","Size Of Overload Relay":"S00","For Main Current Circuit":"screw-type terminals","Temperature Compensation":"-25 ... +60 °C","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Screwdriver Tip":"Pozidriv PZ 2","according to IEC 60068-2-27":"15g / 11 ms; Signaling contact 97 / 98 in position \"Tripped\": 9g / 11 ms","at AC-3e rated value maximum":"690 V","Substance Prohibitance (Date)":"10/01/2009","Design Of The Auxiliary Switch":"integrated","Design Of The Overload Release":"electronic","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"4 A","for AC motors at 500 V at 50 Hz":"0.37 ... 2.2 kW","for AC motors at 690 V at 50 Hz":"0.55 ... 3 kW","For Auxiliary And Control Circuit":"screw-type terminals","Between Main And Auxiliary Circuit":"690 V","Relative Humidity During Operation":"10 ... 95 %","With Type Of Assignment 2 Required":"gG: 20 A","Display Version For Switching Status":"Slide switch","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"gG: 35 A, RK5: 15 A","for 3-phase motors at 400 V at 50 Hz":"0.37 ... 1.5 kW","Of The Auxiliary And Control Contacts":"M3","for AWG cables for auxiliary contacts":"1x (20 ... 14), 2x (20 ... 14)","Between Auxiliary And Auxiliary Circuit":"300 V","due to burst according to IEC 61000-4-4":"2 kV (power ports), 1 kV (signal ports) corresponds to degree of severity 3","reference code according to IEC 81346-2":"F","Finely Stranded With Core End Processing":"1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","operational current at AC-3e at 400 V rated value":"4 A","Size Of Contactor Can Be Combined Company-Specific":"S00","electrostatic discharge according to IEC 61000-4-2":"6 kV contact discharge / 8 kV air discharge","Type Of Voltage Supply Via Input/Output Link Master":"No","contact rating of auxiliary contacts according to UL":"B600 / R300","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gG: 6 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Product Component Removable Terminal For Auxiliary And Control Circuit":"Yes","power loss [W] for rated value of the current at AC in hot operating state":"0.1 W","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"1 ... 4 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d6a09135ec84329acecc00e1edf25e0e.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=725709&mlfb=3RB3016-1PB0-ZW96"},"ai":{"faq":[{"question":"What does the note 'for message tripped' mean on the 3RB3016-1PB0-ZW96?","answer":"The note indicates the signaling contact (terminals 97/98) changes state specifically when the overload relay has tripped — it is not a general status or pre-alarm output. The contact rating under tripped condition is derated to 9g / 11 ms shock resistance vs 15g for the main contacts."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RB3016-1PB0-ZW96","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RB3016-1PB0-ZW96 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}