{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RB3016-1PE0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RB3016-1PE0","canonicalUrl":"https://aoctrl.com/siemens/3RB3016-1PE0","factsUrl":"https://aoctrl.com/api/mcp/products/3RB3016-1PE0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS solid-state overload relay, 3RB3016-1PE0, 4 A thermal current, Trip Class 10E, spring-loaded terminals, Size S00.","salesMarkdown":"The Siemens 3RB3016-1PE0 is a SIRIUS solid-state overload relay in the S00 frame size, rated for a thermal current of 4 A with Trip Class 10E. It protects motors against overloads and phase loss using an electronic sensing element that eliminates the drift common to bimetal relays. The auxiliary contact is integrated and switches at 4 A AC-15 or 2 A at 24 V DC, making it suitable for signaling a tripped state directly to a PLC. ## Mounting and Termination Mounts directly to a contactor via the fastening method; any orientation allowed. Spring-loaded terminals on the main current circuit accept solid or stranded conductors 2x (0.25…1.5 mm²). The auxiliary screw terminals require a Pozidriv PZ2 driver with a 5–6 mm shaft diameter. Depth is 90 mm, width 45 mm, height 72 mm — fits within the S00 footprint without extra DIN-rail space. Shock resistance tested at 15 g / 11 ms (signaling contact 9 g / 11 ms when tripped) per IEC 60068-2-27, and vibration resistance per 1–6 Hz, 15 mm; 6–500 Hz, 20 m/s², 10 cycles. Substance prohibition date of 10/01/2009 indicates RoHS compliance. The part carries a lifecycle status of current production — available for quoting against new orders.","metaTitle":"Siemens 3RB3016-1PE0 SIRIUS Solid-State Overload Relay, 4 A,","metaDescription":"Siemens 3RB3016-1PE0 SIRIUS solid-state overload relay, 4 A thermal current, Trip Class 10E, spring-loaded terminals, Size S00. Active production. Source to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Overload Relays"],"specifications":{"Note":"for message \"tripped\"","Depth":"90 mm","Solid":"2x (0.25 ... 1.5 mm²)","Width":"45 mm","title":"3RB3016-1PE0","Height":"72 mm","at 24 V":"2 A","at 60 V":"0.55 A","Per Pole":"0.03 W","at 110 V":"0.3 A","at 120 V":"4 A","at 125 V":"0.3 A","at 220 V":"0.11 A","at 230 V":"3 A","Trip Class":"CLASS 10E","Rated Value":"690 V","description":"Overload relay 1...4 A Electronic For motor protection Size S00, Class 10E Contactor mounting Main circuit: Spring-type terminal Auxiliary circuit: Spring-type terminal Manual-Automatic-Reset","During Storage":"-40 ... +80 °C","Thermal Current":"4 A","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","During Transport":"-40 ... +80 °C","Fastening Method":"Contactor mounting","Shock Resistance":"15g / 11 ms","Mounting Position":"any","Solid Or Stranded":"2x (0,25 ... 1,5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"solid-state overload relay","Vibration Resistance":"1-6 Hz, 15 mm; 6-500 Hz, 20 m/s²; 10 cycles","at 480 V rated value":"4 A","at 600 V rated value":"4 A","Size Of Overload Relay":"S00","For Main Current Circuit":"spring-loaded terminals","Temperature Compensation":"-25 ... +60 °C","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Screwdriver Tip":"Pozidriv PZ 2","according to IEC 60068-2-27":"15g / 11 ms; Signaling contact 97 / 98 in position \"Tripped\": 9g / 11 ms","at AC-3e rated value maximum":"690 V","Substance Prohibitance (Date)":"10/01/2009","Design Of The Auxiliary Switch":"integrated","Design Of The Overload Release":"electronic","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"4 A","for AC motors at 500 V at 50 Hz":"0.37 ... 2.2 kW","for AC motors at 690 V at 50 Hz":"0.55 ... 3 kW","For Auxiliary And Control Circuit":"spring-loaded terminals","Between Main And Auxiliary Circuit":"690 V","Relative Humidity During Operation":"10 ... 95 %","With Type Of Assignment 2 Required":"gG: 20 A","Display Version For Switching Status":"Slide switch","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"gG: 35 A, RK5: 15 A","at AWG cables for auxiliary contacts":"1x (24 ... 16), 2x (24 ... 16)","for 3-phase motors at 400 V at 50 Hz":"0.37 ... 1.5 kW","Between Auxiliary And Auxiliary Circuit":"300 V","due to burst according to IEC 61000-4-4":"2 kV (power ports), 1 kV (signal ports) corresponds to degree of severity 3","reference code according to IEC 81346-2":"F","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Finely Stranded Without Core End Processing":"2x (0.25 ... 1.5 mm²)","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","operational current at AC-3e at 400 V rated value":"4 A","Size Of Contactor Can Be Combined Company-Specific":"S00","electrostatic discharge according to IEC 61000-4-2":"6 kV contact discharge / 8 kV air discharge","Type Of Voltage Supply Via Input/Output Link Master":"No","contact rating of auxiliary contacts according to UL":"B600 / R300","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gG: 6 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Product Component Removable Terminal For Auxiliary And Control Circuit":"Yes","power loss [W] for rated value of the current at AC in hot operating state":"0.1 W","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"1 ... 4 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$118.14","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8751ced4cda2bad7e3a667d52f381a8c.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=314018&mlfb=3RB3016-1PE0"},"ai":{"faq":[{"question":"What does the 'Note for message tripped' mean?","answer":"The auxiliary contact (97/98) is dedicated to signaling a tripped condition. The note indicates that this contact position corresponds to the relay having tripped due to overload or phase loss, providing a dry contact signal to a controller or indicator."},{"question":"What is the physical depth of the 3RB3016-1PE0?","answer":"The depth is 90 mm, which includes the body and terminal projections. Width is 45 mm, height is 72 mm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RB3016-1PE0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RB3016-1PE0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}