{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RB3016-1SB0-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RB3016-1SB0-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RB3016-1SB0-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RB3016-1SB0-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS solid-state overload relay, size S00, Class 10E, 12 A thermal current, 690 V rated, screw terminals, contactor mounting, 45 x 79 x 73 mm.","salesMarkdown":"The Siemens SIRIUS 3RB3016-1SB0-ZX95 is a solid-state overload relay in size S00, designed for motor protection in control panels where electronic overload release and a Class 10E trip curve are specified. Rated thermal current is 12 A at up to 690 V, so it covers the full motor FLA range for small drives up to that current. The integrated auxiliary switch provides a dedicated \"tripped\" signal for the PLC or annunciator — no separate aux block needed. ## Trip curve and signal Class 10E trip curve. Electronic overload release compensates from -25 to +60 °C. Integrated auxiliary contact delivers a positive \"tripped\" message. Fastens directly to the contactor — no DIN-rail bracket needed, so it adds no extra width to the motor starter assembly. Size S00 footprint (45 mm wide, 79 mm tall, 73 mm deep) keeps the starter stack compact. Screw terminals on the main circuit accept 1x (0.5…4 mm²) or 2x (0.5…2.5 mm²) solid/stranded, Pozidriv PZ2 driver.","metaTitle":"Siemens SIRIUS 3RB3016-1SB0-ZX95 Solid-State Overload Relay,","metaDescription":"Siemens SIRIUS 3RB3016-1SB0-ZX95 solid-state overload relay, Class 10E, 12 A thermal current, 690 V rated. S00 size, contactor mount. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Overload Relays"],"specifications":{"Note":"for message \"tripped\"","Depth":"73 mm","Solid":"1x (0.5 ... 4 mm²), 2x (0.5 ... 2.5 mm²)","Width":"45 mm","Height":"79 mm","at 24 V":"2 A","at 60 V":"0.55 A","Per Pole":"0.2 W","at 110 V":"0.3 A","at 120 V":"4 A","at 125 V":"0.3 A","at 220 V":"0.11 A","at 230 V":"3 A","Trip Class":"CLASS 10E","Rated Value":"690 V","During Storage":"-40 ... +80 °C","Thermal Current":"12 A","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","During Transport":"-40 ... +80 °C","Fastening Method":"Contactor mounting","Shock Resistance":"15g / 11 ms","For Main Contacts":"M3","Mounting Position":"any","Solid Or Stranded":"1x (0,5 ... 4 mm²), 2x (0,5 ... 2,5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"solid-state overload relay","Vibration Resistance":"1-6 Hz, 15 mm; 6-500 Hz, 20 m/s²; 10 cycles","at 480 V rated value":"12 A","at 600 V rated value":"12 A","Size Of Overload Relay":"S00","For Main Current Circuit":"screw-type terminals","Temperature Compensation":"-25 ... +60 °C","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Screwdriver Tip":"Pozidriv PZ 2","according to IEC 60068-2-27":"15g / 11 ms; Signaling contact 97 / 98 in position \"Tripped\": 9g / 11 ms","at AC-3e rated value maximum":"690 V","Substance Prohibitance (Date)":"10/01/2009","Design Of The Auxiliary Switch":"integrated","Design Of The Overload Release":"electronic","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"12 A","for AC motors at 500 V at 50 Hz":"1.5 ... 5.5 kW","for AC motors at 690 V at 50 Hz":"2.2 ... 7.5 kW","For Auxiliary And Control Circuit":"screw-type terminals","Between Main And Auxiliary Circuit":"690 V","Relative Humidity During Operation":"10 ... 95 %","With Type Of Assignment 2 Required":"gG: 50 A, J: 45 A","Display Version For Switching Status":"Slide switch","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"gG: 50 A, RK5: 45 A","for 3-phase motors at 400 V at 50 Hz":"1.5 ... 5.5 kW","Of The Auxiliary And Control Contacts":"M3","for AWG cables for auxiliary contacts":"1x (20 ... 14), 2x (20 ... 14)","Between Auxiliary And Auxiliary Circuit":"300 V","due to burst according to IEC 61000-4-4":"2 kV (power ports), 1 kV (signal ports) corresponds to degree of severity 3","reference code according to IEC 81346-2":"F","Finely Stranded With Core End Processing":"1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","For Main Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","For Auxiliary Contacts With Screw-Type Terminals":"0.8 ... 1.2 N·m","operational current at AC-3e at 400 V rated value":"12 A","Size Of Contactor Can Be Combined Company-Specific":"S00","electrostatic discharge according to IEC 61000-4-2":"6 kV contact discharge / 8 kV air discharge","Type Of Voltage Supply Via Input/Output Link Master":"No","contact rating of auxiliary contacts according to UL":"B600 / R300","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gG: 6 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Product Component Removable Terminal For Auxiliary And Control Circuit":"Yes","power loss [W] for rated value of the current at AC in hot operating state":"0.6 W","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"3 ... 12 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=406936&mlfb=3RB3016-1SB0-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RB3016-1SB0-ZX95/alternatives.json"},"ai":{"faq":[{"question":"What is the 3RB3016-1SB0-ZX95's listed note for message \"tripped\"?","answer":"The part is specified \"for message 'tripped'\", meaning its integrated auxiliary contact is dedicated to signaling the tripped state — useful for a hardwired fault indication."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RB3016-1SB0-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RB3016-1SB0-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}