{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RB3016-2PE0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RB3016-2PE0","canonicalUrl":"https://aoctrl.com/siemens/3RB3016-2PE0","factsUrl":"https://aoctrl.com/api/mcp/products/3RB3016-2PE0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RB3016-2PE0 solid-state overload relay, Size S00, CLASS 20E, 4 A thermal current, 690 V rated, contactor mounting, spring-loaded terminals.","salesMarkdown":"## Current production, CLASS 20E, 4 A thermal current The 3RB3016-2PE0: Rated thermal current Ith is 4 A, with the same 4 A rating at both 480 V and 600 V rated value — the current limit is consistent across common industrial voltages. Trip class CLASS 20E means the relay allows up to 20 seconds of locked-rotor current before tripping, matching the typical starting profile of standard AC-3e motor loads without nuisance trips. ## SIRIUS S00 solid-state overload relay Fastening method is contactor mounting — it snaps directly onto the matching SIRIUS contactor (e.g., 3RT201 or 3RT202 series), saving panel width and wiring compared to a separate block. Dimensions: 45 mm wide, 72 mm high, 90 mm deep — fits standard S00 contactor footprint; mounting position is any orientation. ## Auxiliary contact ratings and environmental limits Shock resistance: 15g / 11 ms for the relay body; the signaling contact in 'tripped' position withstands 9g / 11 ms. Vibration resistance per IEC 60068-2-27: 1-6 Hz at 15 mm amplitude, 6-500 Hz at 20 m/s², 10 cycles. Storage and transport temperature: -40 to +80 °C — wide enough for unheated warehouses and trucking. ## Sourcing and compliance Substance prohibitance date listed as 10/01/2009 — this aligns with RoHS compliance; the relay is designed for global markets with standard environmental restrictions.","metaTitle":"Siemens 3RB3016-2PE0 SIRIUS Solid-State Overload Relay","metaDescription":"Siemens 3RB3016-2PE0 SIRIUS solid-state overload relay, CLASS 20E, 4 A thermal current, 690 V rated. Current production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Overload Relays"],"specifications":{"Note":"for message \"tripped\"","Depth":"90 mm","Solid":"2x (0.25 ... 1.5 mm²)","Width":"45 mm","title":"3RB3016-2PE0","Height":"72 mm","at 24 V":"2 A","at 60 V":"0.55 A","Per Pole":"0.03 W","at 110 V":"0.3 A","at 120 V":"4 A","at 125 V":"0.3 A","at 220 V":"0.11 A","at 230 V":"3 A","Trip Class":"CLASS 20E","Rated Value":"690 V","description":"Overload relay 1...4 A Electronic For motor protection Size S00, Class 20E Contactor mounting Main circuit: Spring-type terminal Auxiliary circuit: Spring-type terminal Manual-Automatic-Reset","During Storage":"-40 ... +80 °C","Thermal Current":"4 A","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","During Transport":"-40 ... +80 °C","Fastening Method":"Contactor mounting","Shock Resistance":"15g / 11 ms","Mounting Position":"any","Solid Or Stranded":"2x (0,25 ... 1,5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"solid-state overload relay","Vibration Resistance":"1-6 Hz, 15 mm; 6-500 Hz, 20 m/s²; 10 cycles","at 480 V rated value":"4 A","at 600 V rated value":"4 A","Size Of Overload Relay":"S00","For Main Current Circuit":"spring-loaded terminals","Temperature Compensation":"-25 ... +60 °C","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Screwdriver Tip":"Pozidriv PZ 2","according to IEC 60068-2-27":"15g / 11 ms; Signaling contact 97 / 98 in position \"Tripped\": 9g / 11 ms","at AC-3e rated value maximum":"690 V","Substance Prohibitance (Date)":"10/01/2009","Design Of The Auxiliary Switch":"integrated","Design Of The Overload Release":"electronic","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"4 A","for AC motors at 500 V at 50 Hz":"0.37 ... 2.2 kW","for AC motors at 690 V at 50 Hz":"0.55 ... 3 kW","For Auxiliary And Control Circuit":"spring-loaded terminals","Between Main And Auxiliary Circuit":"690 V","Relative Humidity During Operation":"10 ... 95 %","With Type Of Assignment 2 Required":"gG: 20 A","Display Version For Switching Status":"Slide switch","Surge Voltage Resistance Rated Value":"6 kV","With Type Of Coordination 1 Required":"gG: 35 A, RK5: 15 A","for 3-phase motors at 400 V at 50 Hz":"0.37 ... 1.5 kW","for AWG cables for auxiliary contacts":"1x (24 ... 16), 2x (24 ... 16)","Between Auxiliary And Auxiliary Circuit":"300 V","due to burst according to IEC 61000-4-4":"2 kV (power ports), 1 kV (signal ports) corresponds to degree of severity 3","reference code according to IEC 81346-2":"F","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Finely Stranded Without Core End Processing":"2x (0.25 ... 1.5 mm²)","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","operational current at AC-3e at 400 V rated value":"4 A","Size Of Contactor Can Be Combined Company-Specific":"S00","electrostatic discharge according to IEC 61000-4-2":"6 kV contact discharge / 8 kV air discharge","Type Of Voltage Supply Via Input/Output Link Master":"No","contact rating of auxiliary contacts according to UL":"B600 / R300","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gG: 6 A","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Product Component Removable Terminal For Auxiliary And Control Circuit":"Yes","power loss [W] for rated value of the current at AC in hot operating state":"0.1 W","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"1 ... 4 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a5180ded8d313f8100a98ca055318791.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=415860&mlfb=3RB3016-2PE0"},"ai":{"faq":[{"question":"What does the 'tripped' note on 3RB3016-2PE0 mean?","answer":"The note indicates that the auxiliary signaling contact (97/98) changes state when the overload relay trips — it provides a remote 'tripped' indication to a PLC or annunciator."},{"question":"What is the depth of 3RB3016-2PE0?","answer":"The depth is 90 mm, with a width of 45 mm and height of 72 mm — it fits the standard S00 contactor footprint."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RB3016-2PE0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RB3016-2PE0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}