{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RB3143-4UD0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RB3143-4UD0","canonicalUrl":"https://aoctrl.com/siemens/3RB3143-4UD0","factsUrl":"https://aoctrl.com/api/mcp/products/3RB3143-4UD0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS solid-state overload relay, Size S3, 3RB3143-4UD0, 50 A thermal current, adjustable trip classes 5E/10E/20E/30E, screw terminals, contactor mounting.","salesMarkdown":"The Siemens 3RB3143-4UD0 is a SIRIUS solid-state overload relay in Size S3, designed to protect motors against overload and phase imbalance by monitoring motor current and tripping when it exceeds the set threshold. Its adjustable trip classes — CLASS 5E, 10E, 20E, and 30E — let you match the relay's thermal response to the motor's starting characteristics: Class 10E for standard start times, Class 20E for higher-inertia loads, and Class 30E for long-start applications like crushers or centrifuges. Mounts directly onto a contactor via the Fastening Method: Contactor mounting — no separate DIN-rail bracket needed, which saves panel space and simplifies wiring. The relay accepts screw-type terminals for the main current circuit (M6 bolts) and solid/stranded control wiring from 0.25 to 1.5 mm² (2x conductors). Dimensions are 70 mm wide, 106 mm high, and 124 mm deep — fits standard S3 contactor footprints. Withstands shock up to 8g / 11 ms during operation and 15g / 11 ms per IEC 60068-2-27 for the signaling contact in tripped position; vibration resistance is 1–6 Hz at 15 mm amplitude and 6–500 Hz at 20 m/s² for 10 cycles. Storage and transport range is -40 to +80 °C.","metaTitle":"Siemens 3RB3143-4UD0 SIRIUS Solid-State Overload Relay, S3,","metaDescription":"Siemens 3RB3143-4UD0 SIRIUS solid-state overload relay, Size S3, 50 A thermal current, adjustable trip classes 5E–30E. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Overload Relays"],"specifications":{"Note":"for message \"tripped\"","Depth":"124 mm","Solid":"2x (0.25 ... 1.5 mm²)","Width":"70 mm","title":"3RB3143-4UD0","Height":"106 mm","Maximum":"IMotor < upper current setting value x 3.5","Minimum":"IMotor > lower current setting value","at 24 V":"2 A","at 60 V":"0.55 A","Per Pole":"0.3 W","Stranded":"2x 16 mm²","at 110 V":"0.3 A","at 120 V":"4 A","at 125 V":"0.3 A","at 220 V":"0.11 A","at 230 V":"3 A","Trip Class":"CLASS 5E, 10E, 20E and 30E adjustable","Rated Value":"1 000 V","description":"Overload relay 12.5...50 A Electronic For motor protection Size S3, Class 5E...30E Contactor mounting Main circuit: Screw Auxiliary circuit: Spring-type terminal Manual-Automatic-Reset","During Storage":"-40 ... +80 °C","Thermal Current":"50 A","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","During Transport":"-40 ... +80 °C","Fastening Method":"Contactor mounting","Shock Resistance":"8g / 11 ms","For Main Contacts":"M6","Mounting Position":"any","Solid Or Stranded":"2x (0,25 ... 1,5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"solid-state overload relay","Vibration Resistance":"1-6 Hz, 15 mm; 6-500 Hz, 20 m/s²; 10 cycles","at 480 V rated value":"50 A","at 600 V rated value":"50 A","Size Of Overload Relay":"S3","For Main Current Circuit":"screw-type terminals","Temperature Compensation":"-25 ... +60 °C","Design Of Screwdriver Shaft":"Diameter 5 to 6 mm","Size Of The Screwdriver Tip":"Pozidriv PZ 2","according to IEC 60068-2-27":"15g / 11 ms; Signaling contact 97 / 98 in position \"Tripped\": 8g / 11 ms","at AC-3e rated value maximum":"1 000 V","Substance Prohibitance (Date)":"03/01/2017","Design Of The Auxiliary Switch":"integrated","Design Of The Overload Release":"electronic","Operating Frequency Rated Value":"50 ... 60 Hz","Operational Current Rated Value":"50 A","for AC motors at 500 V at 50 Hz":"11 ... 30 kW","for AC motors at 690 V at 50 Hz":"11 ... 45 kW","for remote-reset function at DC":"24 V","For Auxiliary And Control Circuit":"spring-loaded terminals","Between Main And Auxiliary Circuit":"690 V","Relative Humidity During Operation":"10 ... 95 %","With Type Of Assignment 2 Required":"gG: 200 A","Display Version For Switching Status":"Slide switch","Surge Voltage Resistance Rated Value":"8 kV","With Type Of Coordination 1 Required":"gG: 200 A","at AWG cables for auxiliary contacts":"2x (24 ... 16)","for 3-phase motors at 400 V at 50 Hz":"7.5 ... 22 kW","Between Auxiliary And Auxiliary Circuit":"300 V","due to burst according to IEC 61000-4-4":"2 kV (power ports), 1 kV (signal ports) corresponds to degree of severity 3","reference code according to IEC 81346-2":"F","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Finely Stranded Without Core End Processing":"2x (0.25 ... 1.5 mm²)","For Main Contacts With Screw-Type Terminals":"4.5 ... 6 N·m","number of CO contacts for auxiliary contacts":"0","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","operational current at AC-3e at 400 V rated value":"50 A","Size Of Contactor Can Be Combined Company-Specific":"S3","electrostatic discharge according to IEC 61000-4-2":"6 kV contact discharge / 8 kV air discharge","Type Of Voltage Supply Via Input/Output Link Master":"No","contact rating of auxiliary contacts according to UL":"B600 / R300","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Response Time Of The Grounding Protection In Settled State":"1 000 ms","Response Value Current Of The Grounding Protection Minimum":"0.75 x IMotor","Arrangement Of Electrical Connectors For Main Current Circuit":"Top and bottom","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gG: 6 A","insulation voltage with degree of pollution 3 at AC rated value":"1 000 V","Product Component Removable Terminal For Auxiliary And Control Circuit":"Yes","power loss [W] for rated value of the current at AC in hot operating state":"0.9 W","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"12.5 ... 50 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e573d985c47da8f40ebc92f80d3039b6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=629747&mlfb=3RB3143-4UD0"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RB3143-4UD0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RB3143-4UD0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}