{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RE4122-3AA35-4QB0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RE4122-3AA35-4QB0","canonicalUrl":"https://aoctrl.com/siemens/3RE4122-3AA35-4QB0","factsUrl":"https://aoctrl.com/api/mcp/products/3RE4122-3AA35-4QB0","rawCanonicalId":null},"summary":{"shortDescription":"Non-reversing motor starter, Frame size 0, Three phase full voltage, UL horsepower rating Hp@VAC, 2@208, 3@230, 5@460, 7.5@575, Solid-state overload relay, Selectable Trip Cl 5-10-20-30, OLR amp range 6 - 25, 110/120 V AC 50/60Hz coil, Non-combination type, Enclosure NEMA type 1, Indoor general purpose use, Standard width enclosure, Standards: UL 60947-4-1, Certifications: cULus With modifications: 22 mm Start-Stop…","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Solid State Relays"],"specifications":{"at 240 V":"5 kA","at 480 V":"5 kA","at 600 V":"5 kA","Trip Class":"CLASS 5 / 10 / 20 / 30","Weight [Lb]":"8 lb","ON-delay time":"9 ... 38 ms","Test Function":"Yes","External Reset":"Yes","OFF-delay time":"4 ... 16 ms","Reset Function":"Manual, automatic and remote","at AC at 600 V":"5 A","at DC at 250 V":"1 A","lifecycle_stage":"current","Fastening Method":"Surface mounting and installation","Mounting Position":"Vertical","Product Brand Name":"Siemens","Asymmetry Detection":"Yes","Overload Protection":"Yes","Product Designation":"Non-reversing motor starter","Design Of The Housing":"indoors, usable on a general basis","Ground Fault Detection":"Yes","Phase Failure Detection":"Yes","Special Product Feature":"Start-Stop Push Buttons","at 200/208 V rated value":"2 hp","at 220/230 V rated value":"3 hp","at 460/480 V rated value":"5 hp","at 575/600 V rated value":"7.5 hp","Disconnector Functionality":"No","at AC at 50 Hz rated value":"110 V","at AC at 60 Hz rated value":"120 V","Height x Width x Depth [in]":"11 × 7 × 5 in","Design Of The Short-Circuit Trip":"Thermal magnetic circuit breaker","Ambient Temperature During Storage":"-30 ... +65 °C","Ambient Temperature During Operation":"-20 ... +40 °C","Material Of The Conductor For Supply":"CU","Tightening Torque [Lbf·In] For Supply":"18 ... 21 lbf·in","number of NO contacts for main contacts":"3","Material Of The Conductor At Magnet Coil":"CU","Number Of Poles For Main Current Circuit":"3","ambient temperature [°F] during storage":"-22 ... +149 °F","Touch Protection Against Electrical Shock":"NA for enclosed products","Number Of Total Auxiliary Contacts Maximum":"8","Tightening Torque [Lbf·In] At Magnet Coil":"7 ... 10 lbf·in","ambient temperature [°F] during operation":"-4 ... +104 °F","apparent holding power of magnet coil at AC":"6.5 VA","apparent pick-up power of magnet coil at AC":"67 VA","Type Of Electrical Connection Of Magnet Coil":"Screw-type terminals","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"1","with multi-phase operation at AC rated value":"300 V","Type Of Voltage Of The Control Supply Voltage":"AC","operating voltage at AC-3 rated value maximum":"600 V","with single-phase operation at AC rated value":"600 V","Adjustment Range Of Thermal Overload Trip Unit":"6 ... 25","degree of protection NEMA rating of the enclosure":"NEMA 1 standard size enclosure","Type Of Electrical Connection For Auxiliary Contacts":"Screw-type terminals","Material Of The Conductor For Load-Side Outgoing Feeder":"CU","Tightening Torque [Lbf·In] For Load-Side Outgoing Feeder":"18 ... 21 lbf·in","Type Of Electrical Connection For Supply Voltage Line-Side":"Screw-type terminals","Temperature Of The Conductor For Supply Maximum Permissible":"60 °C","Type Of Electrical Connection For Load-Side Outgoing Feeder":"Screw-type terminals","Installation Altitude [Ft] At Height Above Sea Level Maximum":"6 560 ft","Material Of The Conductor At Contactor For Auxiliary Contacts":"CU","number of NC contacts of auxiliary contacts of overload relay":"1","number of NO contacts of auxiliary contacts of overload relay":"1","Temperature Of The Conductor At Magnet Coil Maximum Permissible":"75 °C","Tightening Torque [Lbf·In] At Contactor For Auxiliary Contacts":"7 ... 10 lbf·in","contact rating of auxiliary contacts of contactor according to UL":"10A@600V(A600), 2.5A@600V(Q600)","Material Of The Conductor At Overload Relay For Auxiliary Contacts":"CU","Tightening Torque [Lbf·In] At Overload Relay For Auxiliary Contacts":"7 ... 10 lbf·in","contact rating of auxiliary contacts of overload relay according to UL":"5A@600VAC (B600), 1A@250VDC (R300)","Mechanical Service Life (Operating Cycles) Of The Main Contacts Typical":"10 000 000","Operating Range Factor Control Supply Voltage Rated Value Of Magnet Coil":"0.8 ... 1.1","Temperature Of The Conductor For Load-Side Outgoing Feeder Maximum Permissible":"60 °C","Design Of The Fuse Link For Short-Circuit Protection Of The Main Circuit Required":"Class J","Temperature Of The Conductor At Contactor For Auxiliary Contacts Maximum Permissible":"75 °C","Temperature Of The Conductor At Overload Relay For Auxiliary Contacts Maximum Permissible":"75 °C","type of connectable conductor cross-sections at line-side at AWG cables single or multi-stranded":"2x (16 ... 12), 2x (14 ... 8)","type of connectable conductor cross-sections of magnet coil at AWG cables single or multi-stranded":"2x (20 ... 16), 2x (18 ... 14)","type of connectable conductor cross-sections at AWG cables for load-side outgoing feeder single or multi-stranded":"2x (16 ... 12), 2x (14 ... 8)","type of connectable conductor cross-sections at contactor at AWG cables for auxiliary contacts single or multi-stranded":"2x (20 ... 16), 2x (18 ... 14)","type of connectable conductor cross-sections at overload relay at AWG cables for auxiliary contacts single or multi-stranded":"1x (20 ... 14), 2x (20 ... 14)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4cf6405377b6424e587fa72a562e3f30.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1344519&mlfb=3RE4122-3AA35-4QB0"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RE4122-3AA35-4QB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RE4122-3AA35-4QB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}