{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RF2410-1AC45","brand":"Siemens","brandSlug":"siemens","productSlug":"3RF2410-1AC45","canonicalUrl":"https://aoctrl.com/siemens/3RF2410-1AC45","factsUrl":"https://aoctrl.com/api/mcp/products/3RF2410-1AC45","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RF2410-1AC45, three-phase controlled solid-state contactor, 10.5 A AC-51, 48-600 VAC, zero-point switching, screw terminals, 45 mm width.","salesMarkdown":"The Siemens 3RF2410-1AC45 is a SIRIUS solid-state contactor — a three-phase controlled, zero-point switching device rated for 10.5 A in AC-51 duty (resistive loads like heaters). The zero-point switching means it turns on at the voltage zero crossing, which limits inrush and reduces electrical noise on the line; useful when you're feeding a heater bank or a transformer and don't want the thyristor switching transient coupling into adjacent control wiring. It handles a supply range of 48 to 600 VAC at 50/60 Hz, with an insulation voltage rated at 600 V. The control side draws 30 mA at 30 VDC, with a minimum operational current of 500 mA — so don't plan on switching a dry-contact signal through it; this part wants a real load. Width is 45 mm, depth 96.5 mm, height 95 mm — fits a standard 45 mm slot in a control panel. Side-by-side mounting is allowed, but check the derating curve above 40 °C; the part is rated for full current up to that ambient. Terminals are screw-type for both main and control circuits. Main contacts accept 1x (0.5 to 2.5 mm²) solid or 2x (0.5 to 1.0 mm²) stranded; power wiring up to 6 mm² is possible. AWG equivalents for main contacts are 2x (14 to 10). Strip carefully — the terminal design doesn't forgive stray strands. The AC-51 rating of 10.5 A is the resistive load rating — that's the current it can switch for heater elements, incandescent lamps, or resistive furnaces. For motor loads (AC-53 or AC-55a), you'd need to derate significantly; this part is not intended for direct motor switching without additional coordination. The UL 508 rating is 7 A, which is the conservative figure for North American panel builds — use that for UL-listed equipment. The I²t value of 450 A²·s tells you the let-through energy under fault conditions — useful for sizing upstream fuses. Siemens recommends 3NA3801 fuses (or equivalent) at voltages up to 460 V, with a note that these fuses have a smaller rated current than the semiconductor relay itself. That's intentional: the fuse protects the thyristor, not the load. No IP rating is listed, so it's intended for enclosure mounting only, not washdown areas.","metaTitle":"Siemens 3RF2410-1AC45 SIRIUS Solid-State Contactor, 10.5 A A","metaDescription":"Siemens 3RF2410-1AC45 SIRIUS solid-state contactor, 10.5 A AC-51, 48-600 VAC, zero-point switching. Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"96.5 mm","Width":"45 mm","Height":"95 mm","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$492.39","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f1fe5af5edb9b733714091b5a9032787.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=479365&mlfb=3RF2410-1AC45","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RF2410-1AC45/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RF2410-1AC45","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RF2410-1AC45 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}