{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RG9001-0AB00","brand":"Siemens","brandSlug":"siemens","productSlug":"3RG9001-0AB00","canonicalUrl":"https://aoctrl.com/siemens/3RG9001-0AB00","factsUrl":"https://aoctrl.com/api/mcp/products/3RG9001-0AB00","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3RG9001-0AB00, AS-Interface digital output module, 4 relay outputs, IP67, 27mm depth, 45mm width, 90mm height.","salesMarkdown":"## EOL hot — 4 relay outputs, IP67 field module The Siemens 3RG9001-0AB00 is an AS-Interface digital output module with 4 relay outputs, housed in an IP67-rated enclosure for direct field mounting without a control cabinet. The relay outputs switch DC loads up to 1 A (DC-13 at 24 V) or 0.5 A (DC-13 at 24 V) depending on the load type, with a total aggregate current of 2 A across all outputs. ## External 24V AUX required — relay hold state on comms loss The module requires an external auxiliary power supply (AUX POWER) of 20 to 30 V DC, compliant with VDE 0106 (PELV), protection class III, to energize the output circuits. This supply connects via an M12 connector. During a communication failure on the AS-Interface bus, the relay outputs remain in their current switching state — no drop-out, no default. This behavior is critical for fail-safe applications where outputs must hold position rather than revert to a safe-off state. ## Mounting and connectivity — DIN rail or wall, M12 screw terminals The I/O connections use M12 screw-type terminals (4 sockets for outputs D0–D3), with contact pins on the FK or Pg coupling module for the AS-Interface bus. Dimensions: 27 mm depth, 45 mm width, 90 mm height. The IP67 rating means the module withstands washdown environments — suitable for food-and-bev or wet-area deployment without an enclosure.","metaTitle":"Siemens 3RG9001-0AB00 Digital Output Module, 4 Relay Outputs","metaDescription":"Siemens 3RG9001-0AB00 AS-Interface digital output module with 4 relay outputs, IP67, EOL hot. Requires external 24V AUX supply. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Digital Output Modules"],"specifications":{"Type":"4 outputs","Depth":"27mm","Width":"45mm","title":"3RG9001-0AB00","Height":"90mm","Note 1":"An external additional supply (AUX POWER) of 20 to 30 V DC is required for the supply of the output circuits. The additional supply must comply with VDE 0106 (PELV), protection class III.","Note 2":"During a communication failure the relay outputs remain in the current switching state","Socket":"output (D0)","ID code":"0","Socket 2":"output (D1)","Socket 3":"output (D2)","Socket 4":"output (D3)","Connection":"using contact pins on FK or Pg coupling module","description":"AS Interface user module IP67 Phased-out product!!! For further information, please contact our sales department digital, 4RQ 4 x 1 output, Relay, 1A 4 x M12 socket","Input circuit":"PNP","During Storage":"-40 ... +85°C","display of I/Os":"yellow LED","lifecycle_stage":"eol_hot","During Operation":"-25 ... +85°C","Fastening Method":"standard rail mounting/wall mounting using coupling module","I/O configuration":"8","Number I/O sockets":"4","protection class IP":"IP67","Induction Protection":"built-in","Design Of The Product":"digital I/O modules for operation in the field, IP67 - user modules","Short-Ciruit Protection":"built-in","Design Of The Slave Type":"standard slave","Number Of Digital Inputs":"0","Type Of Switching Output":"relay","Number Of Digital Outputs":"4","output voltage at DC at 24 V":"24 ... 24V","Outputs aggregate current max":"2A","Type Of Voltage Of Output Voltages":"DC","current carrying capacity DC-12/13":"1 A (12 V DC), 0.5 A (DC-13 24 V)","display of AS-Interface/diagnostics":"green LED","AS interface total current input max":"60mA","Outputs external power supply 24 V DC":"using M12 connector","Type Of Voltage Of The Input Voltages":"DC","reference code acc. to DIN EN 61346-2":"K","Property Of The Output Short-Circuit Proof":"Yes","protocol is supported AS-Interface protocol":"Yes","Type Of Electrical Connection Of The Inputs And Outputs":"M12 screw-type terminals","operating voltage according to AS-Interface spezification":"26.5 ... 31.6V","Output Current At Digital Output For Signal <1> Rated Value":"1A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8215123a02ae1ae0c2f2e23741eff2eb.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=444606&mlfb=3RG9001-0AB00"},"ai":{"faq":[{"question":"Does the Siemens 3RG9001-0AB00 need an external auxiliary power supply?","answer":"Yes, an external 20–30 V DC AUX supply is required for the output circuits. The supply must meet VDE 0106 (PELV), protection class III, and connects via an M12 connector."},{"question":"What happens to the outputs during a communication failure?","answer":"The relay outputs remain in their current switching state — they do not change until communication is restored. This is a hold-state behavior, not a safe-off default."},{"question":"What is the pinout of the Siemens 3RG9001-0AB00 module?","answer":"The module has 4 M12 sockets for outputs D0 through D3. The AS-Interface bus connection uses contact pins on the FK or Pg coupling module. A detailed pinout diagram is in the product datasheet."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RG9001-0AB00","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RG9001-0AB00 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}